Diffraction enhanced breast imaging through Monte Carlo simulations

被引:10
|
作者
Cunha, D. M. [1 ,2 ]
Tomal, A. [1 ]
Poletti, M. E. [1 ]
机构
[1] Univ Sao Paulo, FFCLRP, Dept Fis & Matemat, BR-14040901 Ribeirao Preto, SP, Brazil
[2] Univ Fed Uberlandia, Inst Fis, BR-38400902 Uberlandia, MG, Brazil
关键词
Mammography; X-ray diffraction; Elastic scattering; Monte Carlo; X-RAY-SCATTERING; COHERENT SCATTERING; TISSUE SAMPLES; MAMMOGRAPHY; PERFORMANCE; SIGNATURES; REDUCTION; RADIATION; MICROCT; SYSTEM;
D O I
10.1016/j.nima.2010.08.056
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work, the potential use of diffraction effects from elastic scattering for breast imaging through Monte Carlo (MC) simulations was studied. The geometrical model of the compressed breast consisted of a semi-infinite layer, composed of a mixture of adipose and glandular tissue, with five spherical objects within it, simulating different tissue compositions. A pencil beam scanned the breast surface, impinging normally on it. Two receptors were placed under the breast: the first one detected primary photons, while the other detected the scattered photons. Two images of the breast were then obtained, a primary and a scatter image. Results showed that the scatter image provided values of contrast greater than that of primary image, with the possibility to enhance the contribution of a specific breast tissue to image formation. Nevertheless, scatter images also show considerably higher noise. The results obtained indicate that elastic scattering has a great potential to aid in the enhancement of the mammographic image. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:878 / 882
页数:5
相关论文
共 50 条
  • [31] Breast tomosynthesis with monochromatic beams: a feasibility study using Monte Carlo simulations
    Malliori, A.
    Bliznakova, K.
    Sechopoulos, I.
    Kamarianakis, Z.
    Fei, B.
    Pallikarakis, N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (16) : 4681 - 4696
  • [32] Target-filter combination effects on breast tissue characterization using mammographic X-rays: A Monte Carlo simulation study
    Elshemey, Wael M.
    Saif, Refat Abo
    Elfiky, Abdo A.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (04) : 823 - 834
  • [33] Monte Carlo simulations in radiotherapy dosimetry
    Andreo, Pedro
    RADIATION ONCOLOGY, 2018, 13
  • [34] MULTICANONICAL MONTE-CARLO SIMULATIONS
    BERG, BA
    INTERNATIONAL JOURNAL OF MODERN PHYSICS C-PHYSICS AND COMPUTERS, 1993, 4 (02): : 249 - 256
  • [35] Monte Carlo simulations in radiotherapy dosimetry
    Pedro Andreo
    Radiation Oncology, 13
  • [36] Optimisation of the imaging and dosimetric characteristics of an electronic portal imaging device employing plastic scintillating fibres using Monte Carlo simulations
    Blake, S. J.
    McNamara, A. L.
    Vial, P.
    Holloway, L.
    Kuncic, Z.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22) : 6827 - 6840
  • [37] Monte Carlo simulations to study light propagation through the skin of different phototypes
    Palamoni, Otavio P.
    de Magalhaes, Ana C.
    Moriyama, Lilian T.
    de Sousa, Marcelo V. P.
    Fortunato, Thereza C.
    TISSUE OPTICS AND PHOTONICS II, 2022, 12147
  • [38] Bit Patterning in SOAs: Statistical Characterization Through Multicanonical Monte Carlo Simulations
    Ghazisaeidi, Amirhossein
    Vacondio, Francesco
    Bononi, Alberto
    Rusch, Leslie Ann
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 2010, 46 (04) : 570 - 578
  • [39] Increasing the speed of DOSXYZnrc Monte Carlo simulations through the introduction of nonvoxelated geometries
    Babcock, Kerry
    Cranmer-Sargison, Gavin
    Sidhu, Narinder
    MEDICAL PHYSICS, 2008, 35 (02) : 633 - 644
  • [40] Effect of Breast Compression on Lesion Characteristic Visibility with Diffraction-Enhanced Imaging
    Faulconer, Laura S.
    Parham, Chris A.
    Connor, Dean M.
    Kuzmiak, Cherie
    Koomen, Marcia
    Lee, Yeonhee
    Cho, Kyu Ran
    Rafoth, Josh
    Livasy, Chad A.
    Kim, Eunhee
    Zeng, Donglin
    Cole, Elodia
    Zhong, Zhong
    Pisano, Etta D.
    ACADEMIC RADIOLOGY, 2010, 17 (04) : 433 - 440