Collimating Slicer for Optical Integral Field Spectroscopy

被引:2
作者
Laurent, Florence [1 ]
Henault, Francois [2 ]
机构
[1] Univ Lyon, Univ Lyon1, Ens Lyon, CNRS,Ctr Rech Astrophys Lyon UMR5574, F-69230 St Genis Laval, France
[2] Univ Grenoble Alpes, Inst Planetol & Astrophys Grenoble, CNRS, BP 53, F-38041 Grenoble, France
来源
ADVANCES IN OPTICAL AND MECHANICAL TECHNOLOGIES FOR TELESCOPES AND INSTRUMENTATION II | 2016年 / 9912卷
关键词
Integral Field Spectroscopy; Image Slicer; Collimator; Spectrograph;
D O I
10.1117/12.2231701
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Integral Field Spectroscopy (IFS) is a technique that gives simultaneously the spectrum of each spatial sampling element in a given object field. It is a powerful tool which rearranges the data cube (x, y, lambda) represented by two spatial dimensions defining the field and the spectral decomposition in a detector plane. In IFS, the "spatial" unit reorganizes the field and the "spectral" unit is being composed of a classical spectrograph. The development of a Collimating Slicer aims at proposing a new type of integral field spectrograph which should be more compact. The main idea is to combine the image slicer with the collimator of the spectrograph, thus mixing the spatial and spectral units. The traditional combination of slicer, pupil and slit elements and the spectrograph collimator is replaced by a new one composed of a slicer and collimator only. In this paper, the state of the art of integral field spectroscopy using image slicers is described. The new system based onto the development of a Collimating Slicer for optical integral field spectroscopy is depicted. First system analysis results and future improvements are discussed. It finally turns out that this new system looks very promising for low resolution spectroscopy.
引用
收藏
页数:13
相关论文
共 14 条
[1]   The image-slicer, a device for reducing loss of light at slit of stellar spectrograph [J].
Bowen, IS .
ASTROPHYSICAL JOURNAL, 1938, 88 (02) :113-124
[2]   MuSICa: THE MULTI-SLIT IMAGE SLICER FOR THE EST SPECTROGRAPH [J].
Calcines, A. ;
Lopez, R. L. ;
Collados, M. .
JOURNAL OF ASTRONOMICAL INSTRUMENTATION, 2013, 2 (01)
[3]   A new design for integral field spectroscopy with 8-m telescopes [J].
Content, R .
OPTICAL TELESCOPES OF TODAY AND TOMORROW: FOLLOWING IN THE DIRECTION OF TYCHO BRAHE, 1997, 2871 :1295-1305
[4]  
et a Laurent, 2006, P SOC PHOTO-OPT INS, V6273, P71
[5]  
Henault F., 2003, P SOC PHOTO-OPT INS, V5249, P134
[6]   Designing, manufacturing and testing of an advanced image slicer prototype for the James Webb Space Telescope [J].
Laurent, F ;
Macaire, C ;
Blanc, PE ;
Prieto, E ;
Moreaux, G ;
Robert, D ;
Ferruit, P ;
Bonneville, C ;
Hénault, F ;
Robertson, D ;
Schmoll, J .
OPTICAL FABRICATION, METROLOGY, AND MATERIAL ADVANCEMENTS FOR TELESCOPES, 2004, 5494 :196-207
[7]  
Laurent F., 2010, P SOC PHOTO-OPT INS, V7739, P147
[8]   Design of an integral field unit for MUSE, and results from prototyping [J].
Laurent, Florence ;
Henault, Francois ;
Renault, Edgard ;
Bacon, Roland ;
Dubois, Jean-Pierre .
PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2006, 118 (849) :1564-1573
[9]  
Lopez, 2014, P SOC PHOTO-OPT INS, V9147, P1
[10]  
Pierce A. K., 1965, PUBL ASTRON SOC PAC, V77, P216, DOI [10.1086/ 128199, DOI 10.1086/128199]