Precise automated control of fluid volumes inside glass capillaries

被引:8
作者
Daoura, MJ [1 ]
Meldrum, DR [1 ]
机构
[1] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
关键词
automation; biotechnology; detection; fluidics; integrated systems; sample processing; submicroliter;
D O I
10.1109/84.749405
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A precise automated apparatus for controlling the position of small fluid sample volumes inside glass capillaries has been developed as part of an automated system for handling submicroliter reaction volumes for genomic analysis [1], [2], The apparatus uses a linear charge-coupled device (CCD) array, de motor, pneumatic pump, feedback controller, and a digital signal processor (DSP) to detect the menisci and control in real-time the position of fluid in a clear glass capillary with a resolution of 50 mu m. This information is used to infer fluid volumes and control aspiration and dispensing to within 15 nanoliters depending on the inner diameter of the capillary. A computer simulation was developed to determine the effect of thick- and thin-walled capillaries on the detected signals. This simulation showed that, with a geometry appropriate for the overall automated system, a capillary with an inner diameter greater than 0.6 times the outer diameter is optimal to detect the presence of fluid inside the capillary. Thicker walled glass capillaries may be employed if a focusing lens is placed between the light source and the capillary, This result was verified experimentally. [305].
引用
收藏
页码:71 / 77
页数:7
相关论文
共 10 条
  • [1] Bashkin J, 1996, APPL THEOR ELECTROPH, V6, P23
  • [2] A NEW 5-YEAR PLAN FOR THE UNITED-STATES HUMAN GENOME PROJECT
    COLLINS, F
    GALAS, D
    [J]. SCIENCE, 1993, 262 (5130) : 43 - 46
  • [3] DAOURA M, 1996, THESIS U WASHINGTON
  • [4] Capillary tube resistive thermal cycling
    Friedman, NA
    Meldrum, DR
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (14) : 2997 - 3002
  • [5] DNA SEQUENCING USING CAPILLARY ARRAY ELECTROPHORESIS
    HUANG, XHC
    QUESADA, MA
    MATHIES, RA
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (18) : 2149 - 2154
  • [6] LARGE-SCALE DNA SEQUENCING
    HUNKAPILLER, T
    KAISER, RJ
    KOOP, BF
    HOOD, L
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1991, 2 (01) : 92 - 101
  • [7] THE INTERDISCIPLINARY NATURE OF GENOMICS
    MELDRUM, DR
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (04): : 443 - 448
  • [8] A biomechatronic fluid-sample-handling system for DNA processing
    Meldrum, DR
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 1997, 2 (02) : 99 - 109
  • [9] Mullis K, 1992, Biotechnology, V24, P17
  • [10] High-speed DNA genotyping using microfabricated capillary array electrophoresis chips
    Woolley, AT
    Sensabaugh, GF
    Mathies, RA