Comparison of Phase-Locked Loops Used for Frequency Measurements in a Low-Inertia Power Grid with Wind Generation

被引:2
作者
David Guerrero-Bermudez, Orlando [1 ]
Martinez, Sergio [1 ]
Molina, Eder [2 ]
Candelo-Becerra, John E. [3 ]
机构
[1] Univ Politecn Madrid, Escuela Tecn Super Ingn Ind, E-28040 Madrid, Spain
[2] Univ Simon Bolivar, Ctr Invest Audacia, Barranquilla 080002, Colombia
[3] Univ Nacl Colombia, Fac Minas, Dept Energia Elect & Automat, Sede Medellin, Carrera 80 65-223, Medellin 050041, Colombia
关键词
frequency; wind generator; synchronous machine; phase-locked loop; low-inertia power grid; PLL; SYSTEMS; SYNCHRONIZATION; STABILITY; ERROR;
D O I
10.3390/electronics11193226
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The need for more precise frequency measurements in electric power systems is increasing because of the growing penetration of renewable energy and the subsequent reduction in inertia, which gives rise to more intense frequency fluctuations. Phase-locked loops (PLLs) are now more accurate and present faster dynamic responses, helping to implement primary frequency controllers for renewable generators connected to the grid through power electronics. However, there are differences among PLL implementations that affect their behavior when estimating frequency, depending on factors as location, voltage level, or penetration of renewable energy, among other things. How this affects the ability of PLL-based frequency controllers to adequately estimate the instantaneous mismatch between generation and demand, especially in low-inertia power systems, is still unclear, and constitutes an open research topic. This paper contributes to this research effort by presenting a comparative study of different PLL configurations in order to gain insight into their performance in different scenarios in a low-inertia power system with a high share of wind energy. Constant and variable wind speed scenarios are considered, and PLL behavior is assessed in terms of the absolute mean value and the root-mean-square value of the frequency error, and the absolute value of the frequency derivative error. The results show that the PLL behavior depends on the voltage level and the location, and it was found that the further away the PLL is from the source that controls the frequency, the more noise is produced, which impacts the quality of the frequency measurement.
引用
收藏
页数:24
相关论文
共 41 条
  • [1] Aguilera R.P., 2018, Control of Power Electronic Converters and Systems, P31, DOI DOI 10.1016/B978-0-12-805245-7.00002-0
  • [2] [Anonymous], 1973, IEEE T POWER AP SYST, VPA92, P1904, DOI 10.1109/TPAS.1973.293570
  • [3] TRANSFER CAPABILITY OBJECTIVES - A STRATEGIC APPROACH
    MERRILL, HM
    BHAVARAJU, MP
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (05): : 1067 - 1074
  • [4] Comparison of Two Three-Phase PLL Systems for More Electric Aircraft Converters
    Bifaretti, Stefano
    Zanchetta, Pericle
    Lavopa, Elisabetta
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (12) : 6810 - 6820
  • [5] It's Indisputable
    Bloom, Aaron
    Helman, Udi
    Holttinen, Hannele
    Summers, Kate
    Bakke, Jordan
    Brinkman, Gregory
    Lopez, Anthony
    [J]. IEEE POWER & ENERGY MAGAZINE, 2017, 15 (06): : 22 - 30
  • [6] CIGRE Working Group 02 (Study Committee 33), 1990, GUID REPR NETW EL CA
  • [7] A comparison of PLL for online frequency tracking in power grids
    Darambazar, Gandorj
    Moukadem, Ali
    Colicchio, Bruno
    Wira, Patrice
    [J]. PROCEEDINGS OF 2021 IEEE 30TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2021,
  • [8] Gagnon R, 2010, 9TH INTERNATIONAL WORKSHOP ON LARGE-SCALE INTEGRATION OF WIND POWER INTO POWER SYSTEMS AS WELL AS ON TRANSMISSION NETWORKS FOR OFFSHORE WIND POWER PLANTS, P73
  • [9] Godave A, 2018, INT CONF COMPUT
  • [10] Standard SOGI-FLL and Its Close Variants: Precise Modeling in LTP Framework and Determining Stability Region/Robustness Metrics
    Golestan, Saeed
    Guerrero, Josep M.
    Vasquez, Juan. C.
    Abusorrah, Abdullah M.
    Al-Turki, Yusuf