Clinical Outcomes of Second- versus First-Generation Carotid Stents: A Systematic Review and Meta-Analysis

被引:48
作者
Mazurek, Adam [1 ]
Malinowski, Krzysztof [2 ]
Rosenfield, Kenneth [3 ]
Capoccia, Laura [4 ]
Speziale, Francesco [4 ]
de Donato, Gianmarco [5 ]
Setacci, Carlo [5 ]
Wissgott, Christian [6 ]
Sirignano, Pasqualino [4 ]
Tekieli, Lukasz [7 ]
Karpenko, Andrey [8 ]
Kuczmik, Waclaw [9 ]
Stabile, Eugenio [10 ]
Metzger, David Christopher [11 ]
Amor, Max [12 ]
Siddiqui, Adnan H. [13 ]
Micari, Antonio [14 ]
Pieniazek, Piotr [1 ,7 ]
Cremonesi, Alberto [15 ]
Schofer, Joachim [16 ]
Schmidt, Andrej [17 ]
Musialek, Piotr [1 ]
机构
[1] Jagiellonian Univ, John Paul II Hosp, Dept Cardiac & Vasc Dis, PL-31202 Krakow, Poland
[2] Jagiellonian Univ Med Coll, Fac Med, Dept Bioinformat & Telemed, PL-31008 Krakow, Poland
[3] Massachusetts Gen Hosp, Surg Dept, Vasc Surg, Boston, MA 02114 USA
[4] Sapienza Univ Rome, Dept Surg, Vasc & Endovasc Surg Unit, I-00185 Rome, Italy
[5] Univ Siena, Dept Vasc Surg, I-53100 Siena, Italy
[6] Imland Klin Rendsburg, Inst Diagnost & Intervent Radiol Neuroradiol, D-24768 Rendsburg, Germany
[7] Jagiellonian Univ, John Paul II Hosp, Dept Intervent Cardiol, PL-31202 Krakow, Poland
[8] EN Meshalkin Natl Med Res Ctr, Ctr Vasc & Hybrid Surg, Novosibirsk 630055, Russia
[9] Med Univ Silesia, Dept Gen Vasc Surg Angiol & Phlebol, PL-40055 Katowice, Poland
[10] AOR San Carlo, Div Cardiol, I-85100 Potenza, Italy
[11] Wellmont CVA Heart & Vasc Inst, Kingsport, TN 37660 USA
[12] UCCI Polyclin Essey, Dept Intervent Cardiol, F-54270 Nancy, France
[13] SUNY Buffalo, Dept Neurosurg, Buffalo, NY 14203 USA
[14] Univ Messina, Dept Biomed & Dent Sci & Morphol & Funct Imaging, I-98122 Messina, Italy
[15] Humanitas Gavazzeni Hosp, Cardiovasc Dept, I-24125 Bergamo, Italy
[16] Asklepios Clin St Georg, MVZ Dept Struct Heart Dis, D-20099 Hamburg, Germany
[17] Univ Hosp Leipzig, Dept Angiol, D-04103 Leipzig, Germany
关键词
carotid artery stenting; systematic review and meta-analysis; stent design; mesh-covered" dual-layer stents; stroke prevention; HIGH-RISK PATIENTS; DISTAL EMBOLIC PROTECTION; SINGLE-CENTER EXPERIENCE; TERM-FOLLOW-UP; PROXIMAL CEREBRAL PROTECTION; FLOW REVERSAL SYSTEM; DUAL-LAYERED STENTS; MESH-COVERED STENTS; CLOSED-CELL STENTS; ARTERY STENOSIS;
D O I
10.3390/jcm11164819
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Single-cohort studies suggest that second-generation stents (SGS; "mesh stents") may improve carotid artery stenting (CAS) outcomes by limiting peri- and postprocedural cerebral embolism. SGS differ in the stent frame construction, mesh material, and design, as well as in mesh-to-frame position (inside/outside). Objectives: To compare clinical outcomes of SGS in relation to first-generation stents (FGSs; single-layer) in CAS. Methods: We performed a systematic review and meta-analysis of clinical studies with FGSs and SGS (PRISMA methodology, 3302 records). Endpoints were 30-day death, stroke, myocardial infarction (DSM), and 12-month ipsilateral stroke (IS) and restenosis (ISR). A random-effect model was applied. Results: Data of 68,422 patients from 112 eligible studies (68.2% men, 44.9% symptomatic) were meta-analyzed. Thirty-day DSM was 1.30% vs. 4.11% (p < 0.01, data for SGS vs. FGS). Among SGS, both Casper/Roadsaver and CGuard reduced 30-day DSM (by 2.78 and 3.03 absolute percent, p = 0.02 and p < 0.001), whereas the Gore stent was neutral. SGSs significantly improved outcomes compared with closed-cell FGS (30-day stroke 0.6% vs. 2.32%, p = 0.014; DSM 1.3% vs. 3.15%, p < 0.01). At 12 months, in relation to FGS, Casper/Roadsaver reduced IS (-3.25%, p < 0.05) but increased ISR (+3.19%, p = 0.04), CGuard showed a reduction in both IS and ISR (-3.13%, -3.63%; p = 0.01, p < 0.01), whereas the Gore stent was neutral. Conclusions: Pooled SGS use was associated with improved short- and long-term clinical results of CAS. Individual SGS types, however, differed significantly in their outcomes, indicating a lack of a "mesh stent" class effect. Findings from this meta-analysis may provide clinically relevant information in anticipation of large-scale randomized trials.
引用
收藏
页数:24
相关论文
共 238 条
  • [61] Impact of Glomerular Filtration Rate on Clinical Outcomes After Carotid Artery Revascularization in 11,832 Patients From the CARE Registry®
    Gruberg, Luis
    Jeremias, Allen
    Rundback, John H.
    Anderson, H. Vernon
    Spertus, John A.
    Kennedy, Kevin F.
    Rosenfield, Kenneth A.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (02) : 246 - 254
  • [62] Long-term results of carotid stenting versus endarterectomy in high-risk patients
    Gurm, Hitinder S.
    Yadav, Jay S.
    Fayad, Pierre
    Katzen, Barry T.
    Mishkel, Gregory J.
    Bajwa, Tanvir K.
    Ansel, Gary
    Strickman, Neil E.
    Wang, Hong
    Cohen, Sidney A.
    Massaro, Joseph M.
    Cutlip, Donald E.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (15) : 1572 - 1579
  • [63] Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy
    Halliday, Alison
    Bulbulia, Richard
    Bonati, Leo H.
    Chester, Johanna
    Cradduck-Bamford, Andrea
    Peto, Richard
    Pan, Hongchao
    [J]. LANCET, 2021, 398 (10305) : 1065 - 1073
  • [64] Cerebral microembolization after protected carotid artery stenting in surgical high-risk patients: Results of a 2-year prospective study
    Hammer, FD
    Lacroix, V
    Duprez, T
    Grandin, C
    Verhelst, R
    Peeters, A
    Cosnard, G
    [J]. JOURNAL OF VASCULAR SURGERY, 2005, 42 (05) : 847 - 853
  • [65] Hart JP, 2010, J CARDIOVASC SURG, V51, P799
  • [66] Thirty day results of 227 consecutive carotid stent procedures performed in carotid stenting clinical trials
    Heck, D.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2009, 1 (02) : 154 - 158
  • [67] Carotid angioplasty and stenting in octogenarians: Is it safe?
    Henry, M.
    Henry, I.
    Polydorou, A.
    Hugel, M.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (03) : 309 - 317
  • [68] Bilateral carotid angioplasty and stenting
    Henry, M
    Gopalakrishnan, L
    Rajagopal, S
    Rath, PC
    Henry, I
    Hugel, M
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 64 (03) : 275 - 282
  • [69] New distal embolic protection device the fibernet® -: 3 dimensional filter:: First carotid human study
    Henry, Michel
    Polydorou, Antonios
    Henry, Isabelle
    Liasis, Nikos
    Polydorou, Adamantia
    Polydorou, Victoria
    Demesticha, Theano
    Skandalakis, Panayiotis
    Kotsiomitis, Evaggelos
    Hugel, Michel
    Sedgewick, Jerry
    Ruth, George
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (07) : 1026 - 1035
  • [70] Comparison Between Proximal Versus Distal Protection Devices in 287 Cases of Carotid Revascularization Using Angioplasty and Stenting: Periprocedure Complications, Morbidity, and Mortality
    Hernandez-Fernandez, Francisco
    Parrilla, G.
    Garcia-Villalba, B.
    Espinosa de Rueda, M.
    Zamarro, J.
    Garrote, M.
    Moreno, A.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (03) : 639 - 645