Electrochemical immunoassay for detection of prostate specific antigen based on peptide nanotube-gold nanoparticle-polyaniline immobilized pencil graphite electrode

被引:74
作者
Vural, Tayfun [1 ]
Yaman, Yesim Tugce [2 ]
Ozturk, Serhat [1 ]
Abaci, Serdar [2 ]
Denkbas, Emir Baki [1 ]
机构
[1] Hacettepe Univ, Biochem Div, Dept Chem, TR-06800 Ankara, Turkey
[2] Hacettepe Univ, Dept Chem, Analyt Chem Div, TR-06800 Ankara, Turkey
关键词
Prostate specific antigen; Biosensor; Peptide nanotube; Polyaniline; Gold nanoparticle; SURFACE MODIFICATION; CANCER; IMMUNOSENSOR; COMPOSITE; ASSAY; PSA; DIAGNOSIS; PLATFORM;
D O I
10.1016/j.jcis.2017.09.079
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this work, we developed a disposable amperometric sandwich-type immunoassay to detect prostate specific antigen (PSA). A self-assembled peptide nanotube (PNT), gold nanoparticle (AuNP) and polyaniline (PANI) composite (PANI/AuNP-PNT) were used to modify a pencil graphite electrode (PGE). Anti-PSA (Abl) was immobilized on the modified electrode (PANI/AuNP-PNT/PGE) to capture PSA. Horseradish peroxidase (HRP) labeled anti-PSA (HRP-Ab2) was used as a tracer antibody. The modified electrodes were characterized with scanning electron microscopy (SEM), thermogravimetric analysis (TGA), energy dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). PSA concentration in phosphate buffer (pH = 7.4) was determined with electro-catalytic reduction of H2O2 on the modified working electrode by using the chronoamperometric method. Limit of detection was found out to be 0.68 ng/mL in a linear range of 1-100 ng/mL with a high regression (R-2 = 0.990). To show the practicality of the modified biosensor in real matrixes, it was successfully applied for the detection of PSA in blood serum samples. The proposed method was also compared with enzyme-linked immunosorbent assay (ELISA) and compatible results were obtained. The developed immunoassay exhibited good reproducibility together with high stability and provides an efficient approach to detect PSA cost-effectively compared to traditional methods. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:318 / 326
页数:9
相关论文
共 65 条
[1]   Biomarkers and biosensors for the early diagnosis of lung cancer [J].
Altintas, Zeynep ;
Tothill, Ibtisam .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 :988-998
[2]   The effects of water molecules on the electronic and structural properties of peptide nanotubes [J].
Andrade-Filho, T. ;
Ferreira, Fabio Furlan ;
Alves, Wendel Andrade ;
Rocha, Alexandre Reily .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (20) :7555-7559
[3]   A novel antibody-antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode [J].
Arkan, Elham ;
Saber, Reza ;
Karimi, Ziba ;
Shamsipur, Mojtaba .
ANALYTICA CHIMICA ACTA, 2015, 874 :66-74
[4]   Polyaniline protected gold nanoparticles based mediator and label free electrochemical cortisol biosensor [J].
Arya, Sunil K. ;
Dey, Abhishek ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2011, 28 (01) :166-173
[5]   Design of self-assembling peptide nanotubes with delocalized electronic states [J].
Ashkenasy, N ;
Horne, WS ;
Ghadiri, MR .
SMALL, 2006, 2 (01) :99-102
[6]   Highly sensitive covalently functionalised integrated silicon nanowire biosensor devices for detection of cancer risk biomarker [J].
Azmi, M. A. Mohd ;
Tehrani, Z. ;
Lewis, R. P. ;
Walker, K. -A. D. ;
Jones, D. R. ;
Daniels, D. R. ;
Doak, S. H. ;
Guy, O. J. .
BIOSENSORS & BIOELECTRONICS, 2014, 52 :216-224
[7]   Biology of prostate-specific antigen [J].
Balk, SP ;
Ko, YJ ;
Bubley, GJ .
JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (02) :383-391
[8]   Screening for prostate cancer with prostate-specific antigen: beware the biases [J].
Bunting, PS .
CLINICA CHIMICA ACTA, 2002, 315 (1-2) :71-97
[9]   Detection of cancer cells using a peptide nanotube-folic acid modified graphene electrode [J].
Castillo, John J. ;
Svendsen, Winnie E. ;
Rozlosnik, Noemi ;
Escobar, Patricia ;
Martineza, Fernando ;
Castillo-Leon, Jaime .
ANALYST, 2013, 138 (04) :1026-1031
[10]  
Castillo-Leon J., 2011, BIOMATER SCI ENG