Background and purpose: Atrial fibrillation (AF) cardiac radioablation (CR) challenges radiotherapy tracking: multiple small targets close to organs-at-risk undergo rapid differential cardiac contraction and respiratory motion. MR-guidance offers a real-time target tracking solution. This work develops and investigates MRI-guided tracking of AF CR targets with cardiac-induced motion. Materials and methods: A direct tracking method (Trackingdirect) and two indirect tracking methods leveraging population-based surrogacy relationships with the left atria (Tracking(indirect_LA)) or other target (Tracking(indirect_target)) were developed. Tracking performance was evaluated using transverse ECG-gated breathhold MRI images from 15 healthy and 10 AF participants. Geometric and volumetric tracking errors were calculated, defined as the difference between the ground-truth and tracked target centroids and volumes respectively. Transverse, breath-hold, noncardiac-gated cine images were acquired at 4 Hz in 5 healthy and 5 AF participants to qualitatively characterize tracking performance on images more comparable to MRILinac acquisitions. Results: The average 3D geometric tracking errors for Tracking(direct), Tracking(indirect_LA) and Tracking(indirect_target) respectively were 1.7 +/- 1.2 mm, 1.6 +/- 1.1 mm and 1.9 +/- 1.3 mm in healthy participants and 1.7 +/- 1.3 mm, 1.5 +/- 1.0 mm and 1.7 +/- 1.2 mm in AF participants. For Tracking(direct), 88% of analyzed images had 3D geometric tracking errors <3 mm and the average volume tracking error was 1.7 +/- 1. 3 cc. For Trackingdirect on non-cardiac-gated cine images, tracked targets overlapped organsat-risk or completely missed the target area on 2.2% and 0.08% of the images respectively. Conclusion: The feasibility of non-invasive MRI-guided tracking of cardiac-induced AF CR target motion was demonstrated for the first time, showing potential for improving AF CR treatment efficacy. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 145
页数:8
相关论文
共 50 条
  • [21] Evaluation of Target Motion Surrogate Suitability for Cardiac Radioablation of Ventricular Tachycardia
    Prusator, M. T.
    Cammin, J.
    Samson, P.
    Robinson, C. G.
    Cuculich, P.
    Knutson, N.
    Moore, K. M. S.
    Goddu, S. M.
    Hugo, G. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S169 - S170
  • [22] Modeling and incorporating cardiac-induced lung tissue motion in a breathing motion model
    White, Benjamin M.
    Santhanam, Anand
    Thomas, David
    Min, Yugang
    Lamb, James M.
    Neylon, Jack
    Jani, Shyam
    Gaudio, Sergio
    Srinivasan, Subashini
    Ennis, Daniel
    Low, Daniel A.
    MEDICAL PHYSICS, 2014, 41 (04)
  • [23] Target Motion Compensation in MRI-guided Prostate Biopsy with Static Images
    Tadayyon, Hadi
    Lasso, Andras
    Gill, Sean
    Kaushal, Aradhana
    Guion, Peter
    Fichtinger, Gabor
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5416 - 5419
  • [24] Prevalence of Cardiac Amyloidosis in Patients Referred for Atrial Fibrillation Ablation by Cardiac MRI
    Ngo, Christian
    Cham, Matthew
    Akoum, Nazem W.
    Cheng, Richard
    Masri, Sofia Carolina C.
    CIRCULATION, 2019, 140
  • [25] Atrial fibrosis by cardiac MRI is a correlate for atrial stiffness in patients with atrial fibrillation
    Jérôme Lamy
    Roy Taoutel
    Romy Chamoun
    Joseph Akar
    Steven Niederer
    Hamid Mojibian
    Steffen Huber
    Lauren A. Baldassarre
    Judith Meadows
    Dana C. Peters
    The International Journal of Cardiovascular Imaging, 2024, 40 : 107 - 117
  • [26] Atrial fibrosis by cardiac MRI is a correlate for atrial stiffness in patients with atrial fibrillation
    Lamy, Jerome
    Taoutel, Roy
    Chamoun, Romy
    Akar, Joseph
    Niederer, Steven
    Mojibian, Hamid
    Huber, Steffen
    Baldassarre, Lauren A.
    Meadows, Judith
    Peters, Dana C.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (01): : 107 - 117
  • [27] First MRI-guided MLC-tracking using a deformable motion phantom
    Borman, P.
    Woodhead, P.
    Perrin, M.
    Barberi, E.
    Lagendijk, J.
    Raaymakers, B.
    Fast, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S397 - S398
  • [28] MRI-GUIDED prostate motion tracking by means of multislice-to-volume registration
    Tadayyon, Hadi
    Vikal, Siddharth
    Gill, Sean
    Lasso, Andras
    Fichtinger, Gabor
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [29] Left atrial strain after paroxysmal atrial fibrillation linac-based cardiac radioablation in elderly population
    Troisi, Federica
    Guida, Pietro
    Di Monaco, Antonio
    Romanazzi, Imma
    Vitulano, Nicola
    Quadrini, Federico
    Valenti, Noemi
    Davi, Valerio
    Bonaparte, Ilaria
    Surgo, Alessia
    Carbonara, Roberta
    Di Guglielmo, Fiorella Cristina
    Calbi, Roberto
    Ciliberti, Maria Paola
    Fiorentino, Alba
    Grimaldi, Massimo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (09): : 1961 - 1970
  • [30] Cardiac-induced localized thoracic motion detected by a fiber optic sensing scheme
    Allsop, Thomas
    Lloyd, Glynn
    Bhamber, Ranjeet S.
    Hadzievski, Ljupco
    Halliday, Michael
    Webb, David J.
    Bennion, Ian
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (11)