MRI-guided cardiac-induced target motion tracking for atrial fibrillation cardiac radioablation

被引:5
|
作者
Lydiard, Suzanne [1 ]
Pontre, Beau [2 ]
Hindley, Nicholas [1 ]
Lowe, Boris S. [3 ]
Sasso, Giuseppe [2 ,4 ,5 ]
Keall, Paul [1 ]
机构
[1] Univ Sydney, ACRF Image Inst 10, Eveleigh, Australia
[2] Univ Auckland, Dept Anat & Med Imaging, Auckland, New Zealand
[3] Green Lane Cardiovasc Serv, Auckland, New Zealand
[4] Auckland City Hosp, Radiat Oncol Dept, Auckland, New Zealand
[5] Univ Auckland, Dept Oncol, Auckland, New Zealand
基金
英国医学研究理事会; 澳大利亚国家健康与医学研究理事会;
关键词
Atrial fibrillation; Cardiac arrhythmias; Radioablation; MRI-Linac; Stereotactic radiotherapy; Non-invasive; ABLATION; CATHETER;
D O I
10.1016/j.radonc.2021.09.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Atrial fibrillation (AF) cardiac radioablation (CR) challenges radiotherapy tracking: multiple small targets close to organs-at-risk undergo rapid differential cardiac contraction and respiratory motion. MR-guidance offers a real-time target tracking solution. This work develops and investigates MRI-guided tracking of AF CR targets with cardiac-induced motion. Materials and methods: A direct tracking method (Trackingdirect) and two indirect tracking methods leveraging population-based surrogacy relationships with the left atria (Tracking(indirect_LA)) or other target (Tracking(indirect_target)) were developed. Tracking performance was evaluated using transverse ECG-gated breathhold MRI images from 15 healthy and 10 AF participants. Geometric and volumetric tracking errors were calculated, defined as the difference between the ground-truth and tracked target centroids and volumes respectively. Transverse, breath-hold, noncardiac-gated cine images were acquired at 4 Hz in 5 healthy and 5 AF participants to qualitatively characterize tracking performance on images more comparable to MRILinac acquisitions. Results: The average 3D geometric tracking errors for Tracking(direct), Tracking(indirect_LA) and Tracking(indirect_target) respectively were 1.7 +/- 1.2 mm, 1.6 +/- 1.1 mm and 1.9 +/- 1.3 mm in healthy participants and 1.7 +/- 1.3 mm, 1.5 +/- 1.0 mm and 1.7 +/- 1.2 mm in AF participants. For Tracking(direct), 88% of analyzed images had 3D geometric tracking errors <3 mm and the average volume tracking error was 1.7 +/- 1. 3 cc. For Trackingdirect on non-cardiac-gated cine images, tracked targets overlapped organsat-risk or completely missed the target area on 2.2% and 0.08% of the images respectively. Conclusion: The feasibility of non-invasive MRI-guided tracking of cardiac-induced AF CR target motion was demonstrated for the first time, showing potential for improving AF CR treatment efficacy. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 145
页数:8
相关论文
共 50 条
  • [1] Cardiac Radioablation: MRI-Guided Tracking of Cardiac-Induced Target Motion
    Lydiard, S.
    Pontre, B.
    Hindley, N.
    Lowe, B.
    Sasso, G.
    Keall, P.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Cardiac radioablation for atrial fibrillation: Target motion characterization and treatment delivery considerations
    Lydiard, Suzanne
    Pontre, Beau
    Lowe, Boris S.
    Ball, Helen
    Sasso, Giuseppe
    Keall, Paul
    MEDICAL PHYSICS, 2021, 48 (03) : 931 - 941
  • [3] Atrial fibrillation cardiac radioablation target visibility on magnetic resonance imaging
    Lydiard, Suzanne
    Pontre, Beau
    Lowe, Boris S.
    Keall, Paul
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (3) : 757 - 767
  • [4] Atrial fibrillation cardiac radioablation target visibility on magnetic resonance imaging
    Suzanne Lydiard
    Beau Pontré
    Boris S. Lowe
    Paul Keall
    Physical and Engineering Sciences in Medicine, 2022, 45 : 757 - 767
  • [5] Liver Stiffness Assessment by Tagged MRI of Cardiac-Induced Liver Motion
    Chung, Sohae
    Breton, Elodie
    Mannelli, Lorenzo
    Axel, Leon
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 949 - 955
  • [6] Motion Management and Dose Reconstruction for MRI-Guided Cardiac Radiosurgery
    Ehrbar, S.
    Chamberlain, M.
    Tanadini-Lang, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E455 - E455
  • [7] Target Motion Tracking in MRI-guided Transrectal Robotic Prostate Biopsy
    Tadayyon, Hadi
    Lasso, Andras
    Kaushal, Aradhana
    Guion, Peter
    Fichtinger, Gabor
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (11) : 3135 - 3142
  • [8] Analysis of target motion in STereotactic Arrhythmia Radioablation for atrial fibrillation
    Di Guglielmo, F. C.
    Sanfrancesco, G.
    De Pascali, C.
    Gregucci, F.
    Surgo, A.
    Carbonara, R.
    Ciliberti, M. P.
    Caliandro, M.
    Paulicelli, E.
    Romanazzo, I.
    Di Monaco, A.
    Grimaldi, M.
    Bonaparte, I.
    Fiorentino, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2053 - S2054
  • [9] Real-time registration by tracking for MRI-Guided, cardiac interventions
    Chung, Desmond
    Satkunasingham, Janakan
    Wright, Graham
    Radau, Perry
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [10] Cardiac Radiosurgery for Atrial Fibrillation: Target Motion and Treatment Considerations
    Lydiard, S.
    Pontre, B.
    Lowe, B.
    Keall, P.
    MEDICAL PHYSICS, 2020, 47 (06) : E322 - E322