Oversampling Selective Accumulation Trapped Ion Mobility Spectrometry Coupled to FT-ICR MS: Fundamentals and Applications

被引:51
作者
Benigni, Paolo [1 ]
Fernandez-Lima, Francisco [1 ,2 ]
机构
[1] Florida Int Univ, Dept Chem & Biochem, Miami, FL 33199 USA
[2] Florida Int Univ, Biomol Sci Inst, Miami, FL 33199 USA
关键词
RESONANCE MASS-SPECTROMETRY; INFRARED RADIATIVE DISSOCIATION; COMPENSATED FTICR CELLS; ABSORPTION-MODE SPECTRA; RING ELECTRODE CELL; CYCLOTRON RESONANCE; GAS-PHASE; CRUDE-OIL; DYNAMIC HARMONIZATION; LIQUID-CHROMATOGRAPHY;
D O I
10.1021/acs.analchem.6b01946
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present paper, we describe the fundamentals and analytical advantages of Oversampling Selective Accumulation Trapped Ion Mobility Spectrometry (OSA-TIMS) when coupled to ultrahigh resolution mass analyzers (e.g., FT-ICR MS). During TIMS analysis, ion packages are spatially resolved based on their mobilities along the TIMS analyzer axis and multiple strategies can be utilized during the trapping and elution of the ion population of interest. In the case of OSA-TIMS-FT-ICR MS, the TIMS operation sequence, trapping conditions, and operations are optimized to increase the signal-to-noise and the number of points across the mobility domain, which leads to more accurate mobility and mass measurements. Experimental results show that accurate ion-neutral collision cross sections (<1%) can be measured using OSA-TIMS-FT-ICR MS with high mobility resolving powers (R-IMS up to 250), high mass accuracy (<1 ppm), and ultrahigh mass resolution (R-MS up to 600-1200k at m/z 400) in a single analysis. The analytical advantages of OSA-TIMS over SA-TIMS were illustrated for the analysis of structural peptide isomers (SDGRG and GRGDS [M + H](+)), conformational isomers (AT-hook peptide 3 KRGRGRPRK [M + 2H](+2)), and a complex mixture of polyaromatic hydrocarbons (PAR) from coal tar. Baseline separation of the structural peptide isomers SDGRG and GRGDS, [M + H](+), was observed, and three conformations were identified for the AT-hook peptide 3 KRGRGRPRK [M + 2H](+2) during OSA-TIMS-FT-ICR MS. A 2-fold increase in the number of molecular features and a 2-6-fold signal-to-noise increase was observed for OSA-TIMS when compared with SA-TIMS during the PAR analysis. This work provides the proof-of-principle for further application of OSA-TIMS-FT-ICR MS for the unsupervised analysis of complex mixtures based on the characterization of the conformational space and the assignment of chemical formulas in a single analysis.
引用
收藏
页码:7404 / 7412
页数:9
相关论文
共 93 条
[1]   Isomer separation of polybrominated diphenyl ether metabolites using nanoESI-TIMS-MS [J].
Adams, Kendra J. ;
Montero, Dennise ;
Aga, Diana ;
Fernandez-Lima, Francisco .
INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2016, 19 (2-3) :69-76
[2]   An Added Dimension: GC Atmospheric Pressure Chemical Ionization FTICR MS and the Athabasca Oil Sands [J].
Barrow, Mark P. ;
Peru, Kerry M. ;
Headley, John V. .
ANALYTICAL CHEMISTRY, 2014, 86 (16) :8281-8288
[3]   Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization [J].
Belov, ME ;
Anderson, GA ;
Angell, NH ;
Shen, YF ;
Tolic, N ;
Udseth, HR ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5052-5060
[4]  
Benigni P., 2016, INT J ION MOBILITY S, V1, P10
[5]   Towards unsupervised polyaromatic hydrocarbons structural assignment from SA-TIMS - FTMS data [J].
Benigni, Paolo ;
Marin, Rebecca ;
Fernandez-Lima, Francisco .
INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2015, 18 (3-4) :151-157
[6]   Increasing Polyaromatic Hydrocarbon (PAH) Molecular Coverage during Fossil Oil Analysis by Combining Gas Chromatography and Atmospheric-Pressure Laser Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) [J].
Benigni, Paolo ;
DeBord, J. Daniel ;
Thompson, Christopher J. ;
Gardinali, Piero ;
Fernandez-Lima, Francisco .
ENERGY & FUELS, 2016, 30 (01) :196-203
[7]   Targeted High-Resolution Ion Mobility Separation Coupled to Ultrahigh-Resolution Mass Spectrometry of Endocrine Disruptors in Complex Mixtures [J].
Benigni, Paolo ;
Thompson, Christopher J. ;
Ridgeway, Mark E. ;
Park, Melvin A. ;
Fernandez-Lima, Francisco .
ANALYTICAL CHEMISTRY, 2015, 87 (08) :4321-4325
[8]   Development of a Fourier-transform ion cyclotron resonance mass spectrometer-ion mobility spectrometer [J].
Bluhm, BK ;
Gillig, KJ ;
Russell, DH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (11) :4078-4086
[9]   Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly [J].
Boldin, Ivan A. ;
Nikolaev, Eugene N. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (01) :122-126
[10]   Theory of peak coalescence in Fourier transform ion cyclotron resonance mass spectrometry [J].
Boldin, Ivan A. ;
Nikolaev, Eugene N. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (19) :3213-3219