Ultra low pressure-drop helium-cooled porous-tungsten PFC

被引:15
作者
Sharafat, S. [1 ]
Mills, A.
Youchison, D.
Nygren, R.
Williams, B.
Ghoniem, N.
机构
[1] Univ Calif Los Angeles, Los Angeles, CA 90095 USA
[2] Sandia Natl Labs, Albuquerque, NM 87185 USA
[3] Ultramet Inc, Pacoima, CA 91331 USA
关键词
D O I
10.13182/FST07-15
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A new class of helium-cooled high heat-flux plasma facing heat exchanger (HA) concept is presented. These unique "Foam-In-Tube " HX concepts are composed of a thin tungsten shell integrally bonded to an open-cell tungsten foam core. High heat flux tests show maximum heat loads of 22.4 MW/m(2) using 4 MPa helium at a flow rate of 27 g/s. Based on these impressive performance results, a unique and scalable heat exchanger channel with ultra-low pressure drop through the porous foam is presented. The primary advantage of the new concept is that pressure drop through the porous media and structure temperatures are nearly independent of HX tube length. The concept is modular in design and can be combined to meet divertor size requirements. From a manufacturing and reliability point of view, the advantage of the proposed concept is that it minimizes the need for joining to other functional materials.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 14 条
[1]  
Bejan A., 1995, CONVECTIVE HEAT TRAN, V2nd
[2]  
DEMPSY P, 1995, THESIS U CALIFORNIA
[3]   Critical heat flux testing on screw cooling tube made of RAFM-steel F82H for divertor application [J].
Ezato, K ;
Suzuki, S ;
Dairaku, M ;
Akiba, A .
FUSION ENGINEERING AND DESIGN, 2005, 75-79 :313-318
[4]   Development of ITER divertor vertical target with annular flow concept - I: Thermal-hydraulic characteristics of annular swirl tube [J].
Ezato, K ;
Dairaku, M ;
Taniguchi, M ;
Sato, K ;
Suzuki, S ;
Akiba, M ;
Ibbott, C ;
Tivey, R .
FUSION SCIENCE AND TECHNOLOGY, 2004, 46 (04) :521-529
[5]   EU development of high heat flux components [J].
Linke, J ;
Lorenzetto, P ;
Majerus, P ;
Merola, M ;
Pitzer, D ;
Rödig, M .
FUSION SCIENCE AND TECHNOLOGY, 2005, 47 (03) :678-685
[6]   He-cooled divertor for DEMO: Experimental verification of the conceptual modular design [J].
Norajitra, P ;
Gervash, A ;
Giniyatulin, R ;
Ihli, T ;
Krauss, W ;
Kruessmann, R ;
Kumetsov, V ;
Makhankov, A ;
Mazul, I ;
Ovchinnikov, I .
FUSION ENGINEERING AND DESIGN, 2006, 81 (1-7) :341-346
[7]   Development of a helium-cooled divertor concept: design-related requirements on materials and fabrication technology [J].
Norajitra, P ;
Boccaccini, LV ;
Diegele, E ;
Filatov, V ;
Gervash, A ;
Giniyatulin, R ;
Gordeev, S ;
Heinzel, V ;
Janeschitz, G ;
Konys, J ;
Krauss, W ;
Kruessmann, R ;
Malang, S ;
Mazul, I ;
Moeslang, A ;
Petersen, C ;
Reimann, G ;
Rieth, M ;
Rizzi, G ;
Rumyantsev, M ;
Ruprecht, R ;
Slobodtchouk, V .
JOURNAL OF NUCLEAR MATERIALS, 2004, 329 :1594-1598
[8]   High heat flux tests of mockups with W rod armor [J].
Nygren, RE ;
Youchison, DL ;
McDonald, JM ;
Lutz, TJ ;
O'Dell, JS ;
Ezato, K ;
Sato, K .
FUSION ENGINEERING AND DESIGN, 2003, 66-68 :353-357
[9]  
Oosthuizen P. H., 1999, An Introduction Convective Heat Transfer Analysis
[10]  
ROSENFELD JH, 1993, 15 S FUS ENG, V2, P1210