Trabecular deformations during screw pull-out: a micro-CT study of lapine bone

被引:25
作者
Joffre, Thomas [1 ,2 ]
Isaksson, Per [2 ]
Procter, Philip [1 ]
Persson, Cecilia [1 ]
机构
[1] Uppsala Univ, Div Appl Mat Sci, Dept Engn Sci, Mat Med Grp, Uppsala, Sweden
[2] Uppsala Univ, Dept Engn Sci, Appl Mech, Uppsala, Sweden
关键词
Screws; Implants; Trabecular bone; Pull-out test; Digital volume correlation; Micro-CT; DIGITAL VOLUME CORRELATION; CALCIUM-PHOSPHATE CEMENT; CANCELLOUS BONE; BIOMECHANICAL EVALUATION; OSTEOPOROTIC BONE; IMPLANT STABILITY; AUGMENTATION; FIXATION; STRAIN; STRENGTH;
D O I
10.1007/s10237-017-0891-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The mechanical fixation of endosseous implants, such as screws, in trabecular bone is challenging because of the complex porous microstructure. Development of new screw designs to improve fracture fixation, especially in high-porosity osteoporotic bone, requires a profound understanding of how the structural system implant/trabeculae interacts when it is subjected to mechanical load. In this study, pull-out tests of screw implants were performed. Screws were first inserted into the trabecular bone of rabbit femurs and then pulled out from the bone inside a computational tomography scanner. The tests were interrupted at certain load steps to acquire 3D images. The images were then analysed with a digital volume correlation technique to estimate deformation and strain fields inside the bone during the tests. The results indicate that the highest shear strains are concentrated between the inner and outer thread diameter, whereas compressive strains are found at larger distances from the screw. Tensile strains were somewhat smaller. Strain concentrations and the location of trabecular failures provide experimental information that could be used in the development of new screw designs and/or to validate numerical simulations.
引用
收藏
页码:1349 / 1359
页数:11
相关论文
共 46 条
  • [1] Digital volume correlation: Three-dimensional strain mapping using X-ray tomography
    Bay, BK
    Smith, TS
    Fyhrie, DP
    Saad, M
    [J]. EXPERIMENTAL MECHANICS, 1999, 39 (03) : 217 - 226
  • [2] An approximate model for cancellous bone screw fixation
    Brown, C. J.
    Sinclair, R. A.
    Day, A.
    Hess, B.
    Procter, P.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (04) : 443 - 450
  • [3] Mineralized bone loss in partially edentulous trabeculae of ovariectomized rabbit mandibles
    Cao, T
    Shirota, T
    Ohno, K
    Michi, KI
    [J]. JOURNAL OF PERIODONTAL RESEARCH, 2004, 39 (01) : 37 - 41
  • [4] Factors affecting the pullout strength of cancellous bone screws
    Chapman, JR
    Harrington, RM
    Lee, KM
    Anderson, PA
    Tencer, AF
    Kowalski, D
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 391 - 398
  • [5] Chen Y, 2016, VERIFICATION VALIDAT
  • [6] Pedicle Screw Design and Cement Augmentation in Osteoporotic Vertebrae Effects of Fenestrations and Cement Viscosity on Fixation and Extraction
    Choma, Theodore J.
    Pfeiffer, Ferris M.
    Swope, Ryan W.
    Hirner, Jesse P.
    [J]. SPINE, 2012, 37 (26) : E1628 - E1632
  • [7] Conshohocken W, 2013, F54313E1 ASTM INT
  • [8] Conshohocken W, 2001, F183901 ASTM INT
  • [9] Cornell Charles N, 2003, J Am Acad Orthop Surg, V11, P109
  • [10] About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: A 3D zero-strain study
    Dall'Ara, E.
    Barber, D.
    Viceconti, M.
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (12) : 2956 - 2963