Plasma removal of parylene c

被引:118
作者
Meng, Ellis [1 ]
Li, Po-Ying [2 ]
Tai, Yu-Chong [3 ]
机构
[1] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
[2] Univ So Calif, Dept Elect Engn, Los Angeles, CA 90089 USA
[3] CALTECH, Dept Elect Engn, Pasadena, CA 91125 USA
关键词
D O I
10.1088/0960-1317/18/4/045004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parylene C, an emerging material in microelectromechanical systems, is of particular interest in biomedical and lab-on-a-chip applications where stable, chemically inert surfaces are desired. Practical implementation of Parylene C as a structural material requires the development of micropatterning techniques for its selective removal. Dry etching methods are currently the most suitable for batch processing of Parylene structures. A performance comparison of three different modes of Parylene C plasma etching was conducted using oxygen as the primary reactive species. Plasma, reactive ion and deep reactive ion etching techniques were explored. In addition, a new switched chemistry process with alternating cycles of fluoropolymer deposition and oxygen plasma etching was examined to produce structures with vertical sidewalls. Vertical etch rates, lateral etch rates, anisotropy and sidewall angles were characterized for each of the methods. This detailed characterization was enabled by the application of replica casting to obtain cross sections of etched structures in a non-destructive manner. Application of the developed etch recipes to the fabrication of complex Parylene C microstructures is also discussed.
引用
收藏
页数:13
相关论文
共 46 条
[1]   Downstream oxygen etching characteristics of polymers from the parylene family [J].
Callahan, RRA ;
Pruden, KG ;
Raupp, GB ;
Beaudoin, SP .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2003, 21 (04) :1496-1500
[2]   Effects of gas pressure and substrate temperature on the etching of parylene-N using a remote microwave oxygen plasma [J].
Callahan, RRA ;
Raupp, GB ;
Beaudoin, SP .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2001, 19 (03) :725-731
[3]  
EGITTO FD, 1990, PLASMA DEPOSITION TR, P322
[4]  
FLAMM D, 1984, PLASMA CHEM PLASMA, V1, P317
[5]   POLYMERIZATION OF PARA-XYLYLENE DERIVATIVES (PARYLENE POLYMERIZATION) .2. HEAT-EFFECTS DURING DEPOSITION OF PARYLENE-C AT DIFFERENT TEMPERATURES [J].
GAZICKI, M ;
SURENDRAN, G ;
JAMES, W ;
YASUDA, H .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1985, 23 (08) :2255-2277
[6]   A NEW GENERAL SYNTHETIC METHOD FOR PREPARATION OF LINEAR POLY-P-XYLYLENES [J].
GORHAM, WF .
JOURNAL OF POLYMER SCIENCE PART A-1-POLYMER CHEMISTRY, 1966, 4 (12PA) :3027-&
[7]  
He Q, 2003, BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P995
[8]   Chemical surface modification of poly(p-xylylene) thin films [J].
Herrera-Alonso, M ;
McCarthy, TJ .
LANGMUIR, 2004, 20 (21) :9184-9189
[9]   POLYMERIZATION OF PARA-XYLYLENE DERIVATIVES (PARYLENE POLYMERIZATION) .1. DEPOSITION KINETICS FOR PARYLENE-N AND PARYLENE-C [J].
KRAMER, P ;
SHARMA, AK ;
HENNECKE, EE ;
YASUDA, H .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1984, 22 (02) :475-491
[10]   Improvement of haemocompatibility of metallic stents by polymer coating [J].
Lahann, J ;
Klee, D ;
Thelen, H ;
Bienert, H ;
Vorwerk, D ;
Höcker, H .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (07) :443-448