Enhancement of corrosion resistance and mechanical properties of Mg-1.2Ca-2Bi via a hybrid silicon-biopolymer coating system

被引:28
作者
Bakhsheshi-Rad, H. R. [1 ,2 ]
Hamzah, E. [1 ]
Daroonparvar, M. [1 ]
Kadir, M. R. Abdul [2 ]
Kasiri-Asgarani, M. [3 ]
Staiger, Mark P. [4 ]
机构
[1] Univ Teknol Malaysia, Fac Mech Engn, Dept Mat Mfg & Ind Engn, Johor Baharu 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Fac Biosci & Med Engn, Med Devices & Technol Grp MEDITEG, Johor Baharu 81310, Johor, Malaysia
[3] Islamic Azad Univ, Najafabad Branch, Fac Mat Engn, Adv Mat Res Ctr, Najafabad, Isfahan, Iran
[4] Univ Canterbury, Dept Mech Engn, MacDiarmid Inst Adv Mat & Nanotechnol, Private Bag 4800, Christchurch 8140, New Zealand
关键词
Magnesium; Biomaterial; Polycaprolactone; Microstructure; Corrosion resistance; Mechanical properties; BIODEGRADABLE MG ALLOY; MAGNESIUM ALLOY; BIOMEDICAL APPLICATIONS; ORTHOPEDIC IMPLANTS; COMPOSITE COATINGS; IN-VIVO; BEHAVIOR; CA; PROTECTION; HYDROXYAPATITE;
D O I
10.1016/j.surfcoat.2015.09.039
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this work, a hybrid dual layer surface coating consisting of a silicon (Si) underlayer and poly(s-caprolactone) (PCL) overlayer was investigated that was designed to reduce the corrosion rates of magnesium-based biomaterials. The Si underlayer was 1.2 mu m thick and composed of spherical nanoparticles. The overlayer of PCL was 75.2 mu m thick and comprised network of pores. Corrosion-induced reduction of the compressive strength of a Si/PCL-coated Mg-Ca-Bi alloy was lower than that of the uncoated or Si layer-coated alloys. However, the bonding strength of the Si coating (24.6 MPa) was significantly higher than that of the Si/PCL-coated samples (6.8 MPa). The Si/PCL coating dramatically enhances the charge transfer resistance of the Mg alloy (2.11 k Omega cm(2)) in simulated body fluid when compared with a Si-coated sample (2265.12 k Omega cm(2)). Si/PCL coatings are considered a promising route to control the corrosion rate and mechanical properties of Mg-based biomaterials. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 31 条
[1]   Biocorrosion and osteoconductivity of PCL/nHAp composite porous film-based coating of magnesium alloy [J].
Abdal-hay, Abdalla ;
Amna, Touseef ;
Lim, Jae Kyoo .
SOLID STATE SCIENCES, 2013, 18 :131-140
[2]   Novel sol gel coating of Nb2O5 on magnesium alloy for biomedical applications [J].
Amaravathy, P. ;
Sowndarya, S. ;
Sathyanarayanan, S. ;
Rajendran, N. .
SURFACE & COATINGS TECHNOLOGY, 2014, 244 :131-141
[3]   Bioactive HA/TiO2 coating on magnesium alloy for biomedical applications [J].
Amaravathy, P. ;
Sathyanarayanan, S. ;
Sowndarya, S. ;
Rajendran, N. .
CERAMICS INTERNATIONAL, 2014, 40 (05) :6617-6630
[4]   Al/SiC thermal spray coatings for corrosion protection of Mg-Al alloys in humid and saline environments [J].
Arrabal, R. ;
Pardo, A. ;
Merino, M. C. ;
Mohedano, M. ;
Casajus, P. ;
Merino, S. .
SURFACE & COATINGS TECHNOLOGY, 2010, 204 (16-17) :2767-2774
[5]   An investigation of the corrosion mechanisms of WE43 Mg alloy in a modified simulated body fluid solution: The influence of immersion time [J].
Ascencio, M. ;
Pekguleryuz, M. ;
Omanovic, S. .
CORROSION SCIENCE, 2014, 87 :489-503
[6]   Microstructural, mechanical properties and corrosion behavior of plasma sprayed NiCrAlY/nano-YSZ duplex coating on Mg-1.2Ca-3Zn alloy [J].
Bakhsheshi-Rad, H. R. ;
Hamzah, E. ;
Ismail, A. F. ;
Daroonparvar, M. ;
Kasiri-Asgarani, M. ;
Jabbarzare, S. ;
Medraj, M. .
CERAMICS INTERNATIONAL, 2015, 41 (10) :15272-15277
[7]   Synthesis and corrosion behavior of a hybrid bioceramic-biopolymer coating on biodegradable Mg alloy for orthopaedic implants [J].
Bakhsheshi-Rad, H. R. ;
Hamzah, E. ;
Ismail, A. F. ;
Sharer, Z. ;
Abdul-Kadir, M. R. ;
Daroonparvar, M. ;
Saud, Safaa N. ;
Medraj, M. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2015, 648 :1067-1071
[8]   Fabrication and corrosion behavior of Si/HA nano-composite coatings on biodegradable Mg-Zn-Mn-Ca alloy [J].
Bakhsheshi-Rad, H. R. ;
Hamzah, E. ;
Daroonparvar, M. ;
Yajid, M. A. M. ;
Medraj, M. .
SURFACE & COATINGS TECHNOLOGY, 2014, 258 :1090-1099
[9]   Bi-layer nano-TiO2/FHA composite coatings on Mg-Zn-Ce alloy prepared by combined physical vapour deposition and electrochemical deposition methods [J].
Bakhsheshi-Rad, H. R. ;
Hamzah, E. ;
Daroonparvar, M. ;
Saud, Safaa N. ;
Abdul-kadir, M. R. .
VACUUM, 2014, 110 :127-135
[10]   In-vitro corrosion inhibition mechanism of fluorine-doped hydroxyapatite and brushite coated Mg-Ca alloys for biomedical applications [J].
Bakhsheshi-Rad, H. R. ;
Hamzah, E. ;
Daroonparvar, M. ;
Ebrahimi-Kahrizsangi, R. ;
Medraj, M. .
CERAMICS INTERNATIONAL, 2014, 40 (06) :7971-7982