A Solver for Dynamic PET Reconstructions based on Forward-Backward-Splitting

被引:5
作者
Benning, Martin [1 ]
Heins, Pia [1 ]
Burger, Martin [1 ]
机构
[1] Univ Munster, Inst Computat & Appl Math, D-48149 Munster, Germany
来源
NUMERICAL ANALYSIS AND APPLIED MATHEMATICS, VOLS I-III | 2010年 / 1281卷
关键词
Dynamic Positron Emission Tomography; Inverse Problems; Operator Splitting; Poisson Noise; POSITRON-EMISSION-TOMOGRAPHY; INPUT FUNCTION; IMAGE-RECONSTRUCTION;
D O I
10.1063/1.3498318
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dynamic Positron Emission Tomography allows monitoring physiological processes within the body that can be described by kinetic parameters. However, recovery of these parameters often requires the solution of complex and nonlinear operator equations. Advanced operator splitting techniques allow incorporating a-priori knowledge, e.g. sparsity of minimizers with respect to all exponential basis, into the reconstruction process.
引用
收藏
页码:1967 / 1970
页数:4
相关论文
共 14 条
[1]  
[Anonymous], THESIS
[2]  
Benning M., 2008, IEEE NUCL SCI S NOV
[3]   QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW INVIVO WITH (H2O)-O-15 [J].
BERGMANN, SR ;
FOX, KAA ;
RAND, AL ;
MCELVANY, KD ;
WELCH, MJ ;
MARKHAM, J ;
SOBEL, BE .
CIRCULATION, 1984, 70 (04) :724-733
[4]   A STATISTICAL-MODEL FOR POSITRON EMISSION TOMOGRAPHY - THE EM PARAMETRIC IMAGE-RECONSTRUCTION ALGORITHM - COMMENT [J].
CARSON, RE ;
LANGE, K .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1985, 80 (389) :20-22
[5]   Characterization of the image-derived carotid artery input function using independent component analysis for the quantitation of [18F] fluorodeoxyglucose positron emission tomography images [J].
Chen, K. ;
Chen, X. ;
Renaut, R. ;
Alexander, G. E. ;
Bandy, D. ;
Guo, H. ;
Reiman, E. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (23) :7055-7071
[6]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[7]   An input function estimation method for FDG-PET human brain studies [J].
Guo, Hongbin ;
Renaut, Rosemary A. ;
Chen, Kewei .
NUCLEAR MEDICINE AND BIOLOGY, 2007, 34 (05) :483-492
[8]   FDG-PET parametric imaging by total variation minimization [J].
Guo, Hongbin ;
Renaut, Rosemary A. ;
Chen, Kewei ;
Reiman, Eric .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (04) :295-303
[9]   MEASUREMENT OF ABSOLUTE MYOCARDIAL BLOOD-FLOW WITH (H2O)-O-15 AND DYNAMIC POSITRON-EMISSION TOMOGRAPHY - STRATEGY FOR QUANTIFICATION IN RELATION TO THE PARTIAL-VOLUME EFFECT [J].
IIDA, H ;
KANNO, I ;
TAKAHASHI, A ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
ONO, Y ;
SHISHIDO, F ;
INUGAMI, A ;
TOMURA, N ;
HIGANO, S ;
FUJITA, H ;
SASAKI, H ;
NAKAMICHI, H ;
MIZUSAWA, S ;
KONDO, Y ;
UEMURA, K .
CIRCULATION, 1988, 78 (01) :104-115
[10]  
IIDA H, 1988, CIRCULATION, V78, P1078