Ideal observer model for detection of blood perfusion and flow using ultrasound

被引:0
作者
Zemp, RJ [1 ]
Abbey, CK [1 ]
Insana, MF [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
来源
INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS | 2003年 / 2732卷
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An ideal observer model is developed for the task of detecting blood perfusing or flowing through tissue. The ideal observer theory relies on a linear systems model that describes tissue and blood object functions and electronic noise as random processes. When aliasing is minimal, the system is characterized by a quantity similar to Noise-Equivalent Quanta used in photon imaging modalities. A simple 1-D model is used to illustrate the effect of the system and object parameters on task performance. Velocity and decorrelation are seen to be advantageous for detection. Aliasing can degrade performance. The ideal observer model provides a framework for assessing the performance of Power Doppler ultrasound systems, and may aid in their design.
引用
收藏
页码:318 / 329
页数:12
相关论文
共 10 条
  • [1] OBJECTIVE ASSESSMENT OF IMAGE QUALITY - EFFECTS OF QUANTUM NOISE AND OBJECT VARIABILITY
    BARRETT, HH
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (07): : 1266 - 1278
  • [2] Evaluation of tumor angiogenesis with US: Imaging, Doppler, and contrast agents
    Ferrara, KW
    Merritt, CRB
    Burns, PN
    Foster, FS
    Mattrey, RF
    Wickline, SA
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (10) : 824 - 839
  • [3] Jensen J. A., 1996, Estimation of Blood Velocities using Ultrasound-A Signal Processing Approach
  • [4] REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE
    KASAI, C
    NAMEKAWA, K
    KOYANO, A
    OMOTO, R
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03): : 458 - 464
  • [5] POWER DOPPLER US - A POTENTIALLY USEFUL ALTERNATIVE TO MEAN FREQUENCY-BASED COLOR DOPPLER US
    RUBIN, JM
    BUDE, RO
    CARSON, PL
    BREE, RL
    ADLER, RS
    [J]. RADIOLOGY, 1994, 190 (03) : 853 - 856
  • [6] ANGLE INDEPENDENT ULTRASONIC-DETECTION OF BLOOD-FLOW
    TRAHEY, GE
    ALLISON, JW
    VONRAMM, OT
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (12) : 965 - 967
  • [7] STATISTICAL PROPERTIES OF RADIOFREQUENCY AND ENVELOPE-DETECTED SIGNALS WITH APPLICATIONS TO MEDICAL ULTRASOUND
    WAGNER, RF
    INSANA, MF
    BROWN, DG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05): : 910 - 922
  • [8] UNIFIED SNR ANALYSIS OF MEDICAL IMAGING-SYSTEMS
    WAGNER, RF
    BROWN, DG
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (06) : 489 - 518
  • [9] ZEMP RJ, IN PRESS IEEE T ULTR
  • [10] ZEMP RJ, 2003, P SPIE MED IMAGING S