Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins

被引:86
|
作者
Haselberg, Rob [1 ]
Ratnayake, Chitra K. [2 ]
de Jong, Gerhardus J. [1 ]
Somsen, Govert W. [1 ]
机构
[1] Univ Utrecht, Dept Biomed Anal, NL-3508 TB Utrecht, Netherlands
[2] Beckman Coulter Inc, Brea, CA 92822 USA
关键词
Capillary electrophoresis; Electrospray ionization; Intact proteins; Mass spectrometry; Sheathless interfacing; Sheath liquid interfacing; TIME-OF-FLIGHT; ZONE-ELECTROPHORESIS; CE-MS; INTERFACE; COMPLEXES; JUNCTION; SEPARATION; PEPTIDES; EMITTERS; DESIGN;
D O I
10.1016/j.chroma.2010.10.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of a prototype porous tip sprayer for sheathless capillary electrophoresis-mass spectrometry (CE-MS) of intact proteins was studied Capillaries with a porous tip were inserted in a stainless steel needle filled with static conductive liquid and installed in a conventional electrospray ionization (ESI) source Using a BCE of 100 mM acetic acid (pH 3 1) and a positively charged capillary coating a highly reproducible and efficient separation of four model proteins (insulin carbonic anhydrase II ribonuclease A and lysozyme) was obtained The protein mass spectra were of good quality allowing reliable mass determination of the proteins and some of their impurities Sheath-liquid CE-MS using the same porous tip capillary and an isopropanol-water-acetic acid sheath liquid showed slightly lower to similar analyte responses However as noise levels increased with sheath-liquid CE-MS detection limits were improved by a factor 6 5-20 with sheathless CE-MS The analyte response in sheathless CE-MS could be enhanced using a nanoESI source and adding 5% isopropanol to the BCE leading to improved detection limits by 50-fold to 140-fold as compared to sheath liquid interfacing using the same capillary - equivalent to sub-nM detection limits for three out of four proteins Clearly the sheathless porous tip sprayer provides high sensitivity CE-MS of intact proteins (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:7605 / 7611
页数:7
相关论文
共 50 条
  • [21] Negative mode sheathless capillary electrophoresis electrospray ionization-mass spectrometry for metabolite analysis of prokaryotes
    Edwards, JL
    Chisolm, CN
    Shackman, JG
    Kennedy, RT
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1106 (1-2) : 80 - 88
  • [22] Dopant Enriched Nitrogen Gas Combined with Sheathless Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry for Improved Sensitivity and Repeatability in Glycopeptide Analysis
    Kammeijer, Guinevere S. M.
    Kohler, Isabelle
    Jansen, Bas C.
    Hensbergen, Paul J.
    Mayboroda, Oleg A.
    Falck, David
    Wuhrer, Manfred
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 5849 - 5856
  • [23] Analysis of bisphosphonates by capillary electrophoresis-electrospray ionization mass spectrometry
    Huikko, K
    Kostiainen, R
    JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) : 289 - 298
  • [24] Development of capillary zone electrophoresis-electrospray ionization-mass spectrometry for the determination of lamotrigine in human plasma
    Zheng, J
    Jann, MW
    Hon, YY
    Shamsi, SA
    ELECTROPHORESIS, 2004, 25 (13) : 2033 - 2043
  • [25] Dynamic pH junction preconcentration in capillary electrophoresis-electrospray ionization-mass spectrometry for proteomics analysis
    Zhu, Guijie
    Sun, Liangliang
    Dovichi, Norman J.
    ANALYST, 2016, 141 (18) : 5216 - 5220
  • [26] Validation of chiral capillary electrophoresis-electrospray ionization-mass spectrometry methods for ecstasy and methadone in plasma
    Schappler, Julie
    Guillarme, Davy
    Prat, Josiane
    Veuthey, Jean-Luc
    Rudaz, Serge
    ELECTROPHORESIS, 2008, 29 (10) : 2193 - 2202
  • [27] Analysis of Phosphorus-containing Amino Acid-type Herbicides by Sheathless Capillary Electrophoresis/Electrospray Ionization-Mass Spectrometry Using a High Sensitivity Porous Sprayer
    Kawai, Mio
    Iwamuro, Yoshiaki
    Iio-Ishimaru, Reiko
    Chinaka, Satoshi
    Takayama, Nariaki
    Hayakawa, Kazuichi
    ANALYTICAL SCIENCES, 2011, 27 (08) : 857 - 860
  • [28] Optimization and Evaluation of a Sheathless Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry Platform for Peptide Analysis: Comparison to Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Faserl, Klaus
    Sarg, Bettina
    Kremser, Leopold
    Lindner, Herbert
    ANALYTICAL CHEMISTRY, 2011, 83 (19) : 7297 - 7305
  • [29] Analysis of Phosphorus-containing Amino Acid-type Herbicides by Sheathless Capillary Electrophoresis/Electrospray Ionization-Mass Spectrometry Using a High Sensitivity Porous Sprayer
    Mio Kawai
    Yoshiaki Iwamuro
    Reiko Iio-Ishimaru
    Satoshi Chinaka
    Nariaki Takayama
    Kazuichi Hayakawa
    Analytical Sciences, 2011, 27 : 857 - 860
  • [30] CAPILLARY ELECTROPHORESIS-ELECTROSPRAY MASS-SPECTROMETRY FOR RECOMBINANT PROTEINS
    TSUJI, K
    BACZYNSKYJ, L
    BRONSON, GE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 8 - ANYL