Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins

被引:87
作者
Haselberg, Rob [1 ]
Ratnayake, Chitra K. [2 ]
de Jong, Gerhardus J. [1 ]
Somsen, Govert W. [1 ]
机构
[1] Univ Utrecht, Dept Biomed Anal, NL-3508 TB Utrecht, Netherlands
[2] Beckman Coulter Inc, Brea, CA 92822 USA
关键词
Capillary electrophoresis; Electrospray ionization; Intact proteins; Mass spectrometry; Sheathless interfacing; Sheath liquid interfacing; TIME-OF-FLIGHT; ZONE-ELECTROPHORESIS; CE-MS; INTERFACE; COMPLEXES; JUNCTION; SEPARATION; PEPTIDES; EMITTERS; DESIGN;
D O I
10.1016/j.chroma.2010.10.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of a prototype porous tip sprayer for sheathless capillary electrophoresis-mass spectrometry (CE-MS) of intact proteins was studied Capillaries with a porous tip were inserted in a stainless steel needle filled with static conductive liquid and installed in a conventional electrospray ionization (ESI) source Using a BCE of 100 mM acetic acid (pH 3 1) and a positively charged capillary coating a highly reproducible and efficient separation of four model proteins (insulin carbonic anhydrase II ribonuclease A and lysozyme) was obtained The protein mass spectra were of good quality allowing reliable mass determination of the proteins and some of their impurities Sheath-liquid CE-MS using the same porous tip capillary and an isopropanol-water-acetic acid sheath liquid showed slightly lower to similar analyte responses However as noise levels increased with sheath-liquid CE-MS detection limits were improved by a factor 6 5-20 with sheathless CE-MS The analyte response in sheathless CE-MS could be enhanced using a nanoESI source and adding 5% isopropanol to the BCE leading to improved detection limits by 50-fold to 140-fold as compared to sheath liquid interfacing using the same capillary - equivalent to sub-nM detection limits for three out of four proteins Clearly the sheathless porous tip sprayer provides high sensitivity CE-MS of intact proteins (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:7605 / 7611
页数:7
相关论文
共 50 条
[1]  
Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
[2]   A new sheathless electrospray interface for coupling of capillary electrophoresis to ion-trap mass spectrometry [J].
Bendahl, L ;
Hansen, SH ;
Olsen, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (24) :2333-2340
[3]   Analysis of non-covalent protein complexes by capillary electrophoresis-time-of-flight mass spectrometry [J].
Brenner-Weiss, G ;
Kirschöfer, F ;
Kühl, B ;
Nusser, M ;
Obst, U .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :147-153
[4]   A novel sheathless interface for capillary electrophoresis/electrospray ionization mass spectrometry using an in-capillary electrode [J].
Cao, P ;
Moini, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (05) :561-564
[5]   Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated tapered fused-silica capillary with a beveled edge [J].
Chang, YZ ;
Chen, YR ;
Her, GR .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5083-5087
[6]   A simple method for fabrication of silver-coated sheathless electrospray emitters [J].
Chen, YR ;
Her, GR .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (05) :437-441
[7]   Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip [J].
Dahlin, AP ;
Wetterhall, M ;
Liljegren, G ;
Bergström, SK ;
Andrén, P ;
Nyholm, L ;
Markides, KE ;
Bergquist, J .
ANALYST, 2005, 130 (02) :193-199
[8]   CAPILLARY ELECTROPHORESIS ELECTROSPRAY IONIZATION-MASS SPECTROMETRY [J].
EDMONDS, CG ;
LOO, JA ;
BARINAGA, CJ ;
UDSETH, HR ;
SMITH, RD .
JOURNAL OF CHROMATOGRAPHY, 1989, 474 (01) :21-37
[9]   Time of flight versus ion trap MS COUPM to CE to analyse intact proteins [J].
Erny, Guillaume L. ;
Leon, Carlos ;
Marina, Maria Luisa ;
Cifuentes, Alejandro .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (10) :1810-1818
[10]   On-line CE-MS using pressurized liquid junction nanoflow electrospray interface and surface-coated capillaries [J].
Fanali, Salvatore ;
D'Orazio, Giovanni ;
Foret, Frantisek ;
Kleparnik, Karel ;
Aturki, Zeineb .
ELECTROPHORESIS, 2006, 27 (23) :4666-4673