A microstrip transmission line volume coil for human head MR imaging at 4 T

被引:83
作者
Zhang, XL [1 ]
Ugurbil, K [1 ]
Chen, W [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Radiol, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
RF coil; high field; human brain; MR imaging; microstrip transmission line; MTL volume coil;
D O I
10.1016/S1090-7807(03)00004-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-frequency RF volume coil based on the use of microstrip transmission line (MTL) has been developed for in vivo H-1 MR applications on the human head at 4T. This coil is characterized by major advantages: (i) completely distributed coil circuit, (ii) high-quality factor (Q), (iii) simple coil structure, and (iv) better sensitivity and less signal-intensity variation in the MR image of the human head compared with an RF shielded birdcage coil of similar coil size. The proposed MTL volume coil does not require additional RF shielding for preventing Q degradation from radiation losses due to the unique MTL structure; thus, it provides a maximal useable space inside the volume coil when compared with most volume coils available at high fields with the same overall coil size. The intrinsic B I distribution of the MTL volume coil effectively compensates for the dielectric resonance effect at 4 T and improves the signal homogeneity in human head MR images in the transaxial planes. The results of this study demonstrate that the MTL volume coil design provides an efficient and simple solution to RF volume coil design for human MR studies at high fields. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:242 / 251
页数:10
相关论文
共 25 条
[1]   Acquisition of human multislice MR images at 8 Tesla [J].
Abduljalil, AM ;
Kangarlu, A ;
Zhang, XL ;
Burgess, RE ;
Robitaille, PML .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) :335-340
[2]  
BAHL IJ, 1977, MICROWAVES, V16, P174
[3]   THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION [J].
CHEN, CN ;
SANK, VJ ;
COHEN, SM ;
HOULT, DI .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :722-729
[4]  
Chen W, 1999, Top Magn Reson Imaging, V10, P63, DOI 10.1097/00002142-199902000-00006
[5]  
Cohn S.B., 1955, Microwave Theory and Techniques, IRE Transactions on, V3, P29
[6]   Experimental determination of the BOLD field strength dependence in vessels and tissue [J].
Gati, JS ;
Menon, RS ;
Ugurbil, K ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :296-302
[7]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[8]  
Hoult DI, 2000, J MAGN RESON IMAGING, V12, P46, DOI 10.1002/1522-2586(200007)12:1<46::AID-JMRI6>3.0.CO
[9]  
2-D
[10]   SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85