Stiffness Dynamics of Rabbit's Achilles Tendons Evaluated by Shear Wave Elastography in vivo

被引:3
|
作者
Yeh, Chia-Lun [1 ]
Kuo, Po-Ling [1 ]
Li, Pai-Chi [1 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Grad Inst Biomed Elect & Bioinformat, Taipei 10764, Taiwan
来源
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2014年
关键词
Shear wave elastography (SWE); Achilles tendon; Christoffel's tensor; TENDINOPATHY;
D O I
10.1109/ULTSYM.2014.0278
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The physiological function of tendon is to withstand the tension generated by muscles during various type of joint movement, and thus prevent muscle from violent damage. Hence, the dynamic change of tendon stiffness for adapting various external forces is highly related to its functional performance. In other words, monitoring the dynamic tendon stiffness at various stretching conditions can be used for assessment of tendon functions. Recently, a relatively new imaging technique called shear wave elastography (SWE) has emerged as a promising tool for estimation of tissue stiffness. However, because tendons are anisotropic materials with the highest stiffness along the longitudinal direction, the general relation between the shear wave speed and Young's modulus derived from isotropic materials (i.e., E= 3 rho c(2)) does not hold. To precisely estimate the mechanical properties of tendon, it is necessary to analyze the velocity dispersion of the guided waves propagating inside tendons. The aim of this study is thus to evaluate SWE combined with dispersion analysis as a diagnostic tool for tendon functionality by monitoring the dynamics of tendon stiffness at various stretching conditions. SWE was in vivo applied to six Achilles tendons of three New Zealand rabbits. Assuming the tendons as a transverse isotropic material, the tendons were passively stretched at four ankle joint angles and the dispersion of shear waves running in parallel with the longitudinal direction of the tendons were analyzed to yield the elastic constants C-55 in Christoffel's tensor. The measured mean value of C-55 at joint angles of 125 degrees,110 degrees,95 degrees and 80 degrees were 0.42MPa, 0.95MPa, 1.49MPa and 2.27MPa, respectively. Our results show that the change of C-55 is highly correlated with the stretching conditions. This suggests that the dynamic stiffness of tendon at various stretching conditions can be monitored by elastic constant C-55. In summary, SWE combined with dispersion analysis is a powerful tool to non-invasively monitor the stiffness dynamic changes of tendons and highly potential for diagnosis of tendon injury and monitoring of the treatment efficiency.
引用
收藏
页码:1132 / 1135
页数:4
相关论文
共 50 条
  • [41] Influence of Load and Transducer Bandwidth on the Repeatability of In Vivo Tendon Stiffness Evaluation Using Shear Wave Elastography
    Obuchowicz, Rafal
    Ambrozinski, Lukasz
    Kohut, Piotr
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2020, 36 (05) : 409 - 420
  • [42] Determining In-vivo placental stiffness in healthy and preeclamptic pregnancies using shear-wave elastography
    Spiliopoulos, Michail
    Kuo, Che-Ying
    Eranki, Avinash
    Iqbal, Sara
    Fisher, John P.
    Fries, Melissa
    Kim, Peter C. W.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2018, 218 (01) : S281 - S281
  • [43] Assessing cardiac stiffness using ultrasound shear wave elastography
    Caenen, Annette
    Pernot, Mathieu
    Nightingale, Kathryn R.
    Voigt, Jens-Uwe
    Vos, Hendrik J.
    Segers, Patrick
    D'hooge, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (02):
  • [44] Anisotropy and reproducibility of ultrasound shear wave elastography in patella tendons with and without tendinopathy
    Holmgren, Jackson G.
    Kottapalli, Vishal
    Ngo, Thien
    Tran, Anthony
    Roberts, Tanner
    Johnson, Trevor
    Gao, Jing
    CLINICAL IMAGING, 2023, 102 : 71 - 77
  • [45] Minimal effect of scanning parameters on ultrasound shear wave elastography variability in tendons
    Zellers, Jennifer A.
    Li, Ran
    Vaidya, Rachana
    Lohse, Keith
    North, Andrew
    Cui, Stephane
    Houston, Bryson
    Chen, Menghan
    Zheng, Jie
    Baxter, Josh
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (09) : 2431 - 2439
  • [46] Can Shoulder Muscle Activity Be Evaluated With Ultrasound Shear Wave Elastography?
    Kim, Kwanwoo
    Hwang, Hyun-Jung
    Kim, Seul-Gi
    Lee, Jin-Hyuck
    Jeong, Woong Kyo
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (06) : 1276 - 1283
  • [47] Shear Wave Elastography of the Achilles Tendon in Primary Hyperparathyroidism: An Observational Prospective Study
    Ozturk, Mesut
    Onar, Mustafa Arda
    Polat, Cafer
    Kan, Elif Kilic
    Polat, Ahmet Veysel
    JOURNAL OF CLINICAL ULTRASOUND, 2025,
  • [48] Assessment of the common carotid artery wall stiffness by Shear Wave Elastography in Behcet's disease
    Alis, Deniz
    Durmaz, Emine Sebnem Memis
    Alis, Ceren
    Tutuncu, Melih
    Saip, Sabahattin
    Kocer, Naci
    Islak, Civan
    Kizilkilic, Osman
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (04) : 446 - 452
  • [49] The association of muscle and tendon elasticity with passive joint stiffness: In vivo measurements using ultrasound shear wave elastography
    Chino, Kentaro
    Takahashi, Hideyuki
    CLINICAL BIOMECHANICS, 2015, 30 (10) : 1230 - 1235
  • [50] Changes in tibial nerve stiffness during ankle dorsiflexion according to in-vivo analysis with shear wave elastography
    Kawanishi, Kengo
    Nariyama, Yuki
    Anegawa, Keisuke
    Tsutsumi, Masahiro
    Kudo, Shintarou
    MEDICINE, 2022, 101 (26) : E29840