Taurolidine-citrate-heparin lock reduces catheter-related bloodstream infections in intestinal failure patients dependent on home parenteral support: a randomized, placebo-controlled trial

被引:59
作者
Tribler, Siri [1 ]
Brandt, Christopher F. [1 ]
Petersen, Anne H. [3 ]
Petersen, Jorgen H. [3 ]
Fuglsang, Kristian A. [1 ]
Staun, Michael [1 ]
Broebech, Per [1 ]
Moser, Claus E. [2 ]
Jeppesen, Palle B. [1 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Med Gastroenterol, Copenhagen, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Dept Clin Microbiol, Copenhagen, Denmark
[3] Univ Copenhagen, Dept Biostat, Copenhagen, Denmark
关键词
antimicrobial catheter lock; bacteremia; catheter infections; catheter-related bloodstream infections; central venous catheter; home parenteral support; intestinal failure; parenteral nutrition; taurolidine; COAGULASE-NEGATIVE STAPHYLOCOCCI; CENTRAL VENOUS CATHETERS; IN-VITRO; RISK-FACTORS; PREVENTION; NUTRITION; GUIDELINES; CHILDREN; EFFICACY; CANCER;
D O I
10.3945/ajcn.117.158964
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: In patients with intestinal failure who are receiving home parenteral support (HPS), catheter-related bloodstream infections (CRBSIs) inflict health impairment and high costs. Objective: This study investigates the efficacy and safety of the antimicrobial catheter lock solution, taurolidine-citrate-heparin, compared with heparin 100 IE/mL on CRBSI occurrence. Design: Forty-one high-risk patients receiving HPS followed in a tertiary HPS unit were randomly assigned in a double-blinded, placebo-controlled trial. External, stratified randomization was performed according to age, sex, and prior CRBSI incidence. The prior CRBSI incidence in the study population was 2.4 episodes/1000 central venous catheter (CVC) days [95% Poisson confidence limits (CLs): 2.12, 2.71 episodes/1000 CVC days]. The maximum treatment period was 2 y or until occurrence of a CRBSI or right-censoring because of CVC removal. The exact permutation tests were used to calculate P values for the log-rank tests. Results: Twenty patients received the taurolidine-citrate-heparin lock and 21 received the heparin lock, with 9622 and 6956 treatment days, respectively. In the taurolidine-citrate-heparin arm, no CRBSIs occurred, whereas 7 CRBSIs occurred in the heparin arm, with an incidence of 1.0/1000 CVC days (95% Poisson CLs: 0.4, 2.07/1000 CVC days; P = 0.005). The CVC removal rates were 0.52/1000 CVC days (95% Poisson CLs: 0.17, 1.21/1000 CVC days) and 1.72/1000 CVC days (95% Poisson CLs: 0.89, 3.0/1000 CVC days) in the taurolidine-citrate-heparin and heparin arm, respectively, tending to prolong CVC survival in the taurolidine arm (P = 0.06). Costs per treatment year were lower in the taurolidine arm ((sic)2348) than in the heparin arm ((sic)6744) owing to fewer admission days related to treating CVC-related complications (P = 0.02). Conclusions: In patients with intestinal failure who are life dependent on HPS, the taurolidine-citrate-heparin catheter lock demonstrates a clinically substantial and cost-beneficial reduction of CRBSI occurrence in a high-risk population compared with heparin.
引用
收藏
页码:839 / 848
页数:10
相关论文
共 47 条
[31]  
Murray EC, 2014, QJM, V107, P997
[32]   Deposits on the intraluminal surface and bacterial growth in central venous catheters [J].
Nishikawa, K. ;
Takasu, A. ;
Morita, K. ;
Tsumori, H. ;
Sakamoto, T. .
JOURNAL OF HOSPITAL INFECTION, 2010, 75 (01) :19-22
[33]  
O'Grady NP, 2011, CLIN INFECT DIS, V52, pE162, DOI [10.1016/j.ajic.2011.01.003, 10.1093/cid/cir257]
[34]   Microbiocidal effects of various taurolidine containing catheter lock solutions [J].
Olthof, E. D. ;
Nijland, R. ;
Gulich, A. F. ;
Wanten, G. J. A. .
CLINICAL NUTRITION, 2015, 34 (02) :309-314
[35]   Absence of microbial adaptation to taurolidine in patients on home parenteral nutrition who develop catheter related bloodstream infections and use taurolidine locks [J].
Olthof, E. D. ;
Rentenaar, R. J. ;
Rijs, A. J. M. M. ;
Wanten, G. J. A. .
CLINICAL NUTRITION, 2013, 32 (04) :538-542
[36]   Taurolidine Lock Is Superior to Heparin Lock in the Prevention of Catheter Related Bloodstream Infections and Occlusions [J].
Olthof, Evelyn D. ;
Versleijen, Michelle W. ;
Huisman-de Waal, Getty ;
Feuth, Ton ;
Kievit, Wietske ;
Wanten, Geert J. A. .
PLOS ONE, 2014, 9 (11)
[37]  
Opilla Marianne, 2008, Am J Infect Control, V36, DOI 10.1016/j.ajic.2008.10.007
[38]   ESPEN guidelines on chronic intestinal failure in adults [J].
Pironi, Loris ;
Arends, Jann ;
Bozzetti, Federico ;
Cuerda, Cristina ;
Gillanders, Lyn ;
Jeppesen, Palle Bekker ;
Joly, Francisca ;
Kelly, Darlene ;
Lal, Simon ;
Staun, Michael ;
Szczepanek, Kinga ;
Van Gossum, Andre ;
Wanten, Geert ;
Schneider, Stephane Michel .
CLINICAL NUTRITION, 2016, 35 (02) :247-307
[39]   ULTRASTRUCTURAL ANALYSIS OF INDWELLING VASCULAR CATHETERS - A QUANTITATIVE RELATIONSHIP BETWEEN LUMINAL COLONIZATION AND DURATION OF PLACEMENT [J].
RADD, I ;
COSTERTON, W ;
SABHARWAL, U ;
SACILOWSKI, M ;
ANAISSIE, E ;
BODEY, GP .
JOURNAL OF INFECTIOUS DISEASES, 1993, 168 (02) :400-407
[40]   Prospective Cohort Study of the Outcome of and Risk Factors for Intravascular Catheter-Related Bloodstream Infections in Children With Intestinal Failure [J].
Robinson, Joan L. ;
Casey, Linda M. ;
Huynh, Hien Q. ;
Spady, Donald W. .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2014, 38 (05) :625-630