A Biomechanical Comparison of Locked and Unlocked Long Cephalomedullary Nails in a Stable Intertrochanteric Fracture Model

被引:0
作者
Kane, Patrick [1 ]
Vopat, Bryan [1 ]
Paller, David [1 ]
Koruprolu, Sarath [1 ]
Daniels, Alan H. [1 ]
Born, Christopher [1 ]
机构
[1] Rhode Isl Hosp, Dept Orthopaed, Providence, RI 02903 USA
基金
美国国家卫生研究院;
关键词
intertochanteric fracture; cephomedullary nail; distal interlocking screw; HIP-FRACTURES; FEMUR FRACTURES; FIXATION; CONSTRUCTS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study compared the torsional properties of stable intertrochanteric femur fractures in a cadaveric bone model using 2 different distal fixation strategies: unlocked long cephalomedullary nailing versus dynamically locked nailing. Methods: Fourteen matched pairs of cadaveric femora were randomly assigned to 1 of 2 distal fixation treatment groups: a single distal interlock screw placed in the dynamic orientation or no distal screw fixation. A stable 2-part intertrochanteric fracture was produced. Specimens were potted and mounted in a double gimbal fixture, facilitating unconstrained motion in the sagittal and coronal planes. Specimens were cyclically loaded dynamically in both internal and external rotation. Range of motion, internal and external rotation stiffness, torsion stiffness, torsion yield, and ultimate torsion magnitude were calculated. Results: The samples instrumented with a distal locking screw reported statistically significantly greater internal (1.54 +/- 0.81 N.m per degree vs. 1.08 +/- 0.35 N$ m per degree; P = 0.026) and external rotational stiffness (1.42 +/- 0.72 N$ m per degree vs. 0.86 +/- 0.36 N$ m per degree; P = 0.009). Samples with locked distal fixation were statistically stiffer and displayed statistically less displacement at the yield and peak torque. The yield torque was statistically significantly higher in the samples without distal fixation (14.2 +/- 3.3 N.m per degree vs. 10.6 +/- 3.8 N.m per degree; P = 0.037). The peak torque was comparable between locked and unlocked samples (15.0 +/- 4.6 N.m per degree vs. 16.2 +/- 4.2 N.m per degree; P = 0.492). Conclusions: Distal locking of femoral intramedullary nails increases the stiffness of the nail-femur construct. Unlocked samples displayed statistically significant higher yield torque while maintaining comparable peak torque as the locked samples. This study indicates that treating stable intertrochanteric fractures with unlocked long intramedullary nails may be an acceptable option, although further clinical study will be needed to test this assertion.
引用
收藏
页码:715 / 720
页数:6
相关论文
共 50 条
  • [41] Biochemical Markers Comparison of Dynamic Hip Screw and Gamma Nail Implants in the Treatment of Stable Intertrochanteric Fracture: a Prospective Study of 60 Patients
    Song, W.
    Chen, Y.
    Shen, H.
    Yuan, T.
    Zhang, C.
    Zeng, B.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2011, 39 (03) : 822 - 829
  • [42] Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation
    Knobe, Matthias
    Nagel, Philipp
    Maier, Klaus-Juergen
    Gradl, Gertraud
    Buecking, Benjamin
    Soenmez, Tolga T.
    Modabber, Ali
    Prescher, Andreas
    Pape, Hans-Christoph
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (01) : E12 - E18
  • [43] A Biomechanical Comparison of Three Miniature Locking Plate Systems in a Rabbit Radial and Ulnar Fracture Model
    Takizawa, Harue
    Honnami, Muneki
    Sakai, Takamasa
    Sasaki, Akari
    Sakamoto, Ayumi
    Mochizuki, Manabu
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2019, 32 (04) : 297 - 304
  • [44] Biomechanical Comparison of Dual and Posterior Locking Plates in an Ex Vivo Comminuted Olecranon Fracture Model
    Sobel, Andrew D.
    Babu, Jacob M.
    Blood, Travis D.
    Paxton, E. Scott
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (08): : 796.e1 - 796.e6
  • [45] BIOMECHANICAL COMPARISON OF TRANS-SACRAL AND TRIANGULAR OSTEOSYNTHESIS IN A VERTICALLY UNSTABLE PELVIC FRACTURE MODEL
    Zamorano, David P.
    Min, Kyong S.
    Wahba, George
    Garcia, Ivan
    Bahtia, Nitin N.
    Lee, Thay Q.
    PROCEEDINGS OF THE 4TH FRONTIERS IN BIOMEDICAL DEVICES CONFERENCE AND EXPOSITION - 2009, 2009, : 105 - 106
  • [46] In Vivo Biomechanical Evaluation of a Novel Angle-Stable Interlocking Nail Design in a Canine Tibial Fracture Model
    Dejardin, Loic M.
    Cabassu, Julien B.
    Guillou, Reunan P.
    Villwock, Mark
    Guiot, Laurent P.
    Haut, Roger C.
    VETERINARY SURGERY, 2014, 43 (03) : 271 - 281
  • [47] Comparison of Femoral Head Rotation and Varus Collapse Between a Single Lag Screw and Integrated Dual Screw Intertrochanteric Hip Fracture Fixation Device Using a Cadaveric Hemi-Pelvis Biomechanical Model
    Santoni, Brandon G.
    Nayak, Aniruddh N.
    Cooper, Seth A.
    Smithson, Ian R.
    Cox, Jacob L.
    Marberry, Scott T.
    Sanders, Roy W.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (04) : 164 - 169
  • [48] Biomechanical Comparison of a Notched Head Locking T-Plate and a Straight Locking Compression Plate in a Juxta-Articular Fracture Model
    Bird, Guy
    Glyde, Mark
    Hosgood, Giselle
    Hayes, Alex
    Day, Robert
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 34 (03) : 161 - 170
  • [49] Quality of life, walking ability and change of living situation after trochanteric femur fracture in geriatric patients-Comparison between sliding hip screw and cephalomedullary nails from the registry for geriatric trauma
    Marks, L.
    Pass, B.
    Knobe, M.
    Volland, R.
    Eschbach, D.
    Lendemans, S.
    Aigner, R.
    Schoeneberg, C.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (07): : 1793 - 1800
  • [50] Additional Tension Screws Improve Stability in Elastic Stable Intramedullary Nailing: Biomechanical Analysis of a Femur Spiral Fracture Model
    Zachert, Gregor
    Rapp, Marion
    Eggert, Rebecca
    Schulze-Hessing, Maaike
    Gros, Nina
    Stratmann, Christina
    Wendlandt, Robert
    Kaiser, Martin M.
    EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2015, 25 (04) : 365 - 372