A Biomechanical Comparison of Locked and Unlocked Long Cephalomedullary Nails in a Stable Intertrochanteric Fracture Model

被引:0
|
作者
Kane, Patrick [1 ]
Vopat, Bryan [1 ]
Paller, David [1 ]
Koruprolu, Sarath [1 ]
Daniels, Alan H. [1 ]
Born, Christopher [1 ]
机构
[1] Rhode Isl Hosp, Dept Orthopaed, Providence, RI 02903 USA
基金
美国国家卫生研究院;
关键词
intertochanteric fracture; cephomedullary nail; distal interlocking screw; HIP-FRACTURES; FEMUR FRACTURES; FIXATION; CONSTRUCTS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study compared the torsional properties of stable intertrochanteric femur fractures in a cadaveric bone model using 2 different distal fixation strategies: unlocked long cephalomedullary nailing versus dynamically locked nailing. Methods: Fourteen matched pairs of cadaveric femora were randomly assigned to 1 of 2 distal fixation treatment groups: a single distal interlock screw placed in the dynamic orientation or no distal screw fixation. A stable 2-part intertrochanteric fracture was produced. Specimens were potted and mounted in a double gimbal fixture, facilitating unconstrained motion in the sagittal and coronal planes. Specimens were cyclically loaded dynamically in both internal and external rotation. Range of motion, internal and external rotation stiffness, torsion stiffness, torsion yield, and ultimate torsion magnitude were calculated. Results: The samples instrumented with a distal locking screw reported statistically significantly greater internal (1.54 +/- 0.81 N.m per degree vs. 1.08 +/- 0.35 N$ m per degree; P = 0.026) and external rotational stiffness (1.42 +/- 0.72 N$ m per degree vs. 0.86 +/- 0.36 N$ m per degree; P = 0.009). Samples with locked distal fixation were statistically stiffer and displayed statistically less displacement at the yield and peak torque. The yield torque was statistically significantly higher in the samples without distal fixation (14.2 +/- 3.3 N.m per degree vs. 10.6 +/- 3.8 N.m per degree; P = 0.037). The peak torque was comparable between locked and unlocked samples (15.0 +/- 4.6 N.m per degree vs. 16.2 +/- 4.2 N.m per degree; P = 0.492). Conclusions: Distal locking of femoral intramedullary nails increases the stiffness of the nail-femur construct. Unlocked samples displayed statistically significant higher yield torque while maintaining comparable peak torque as the locked samples. This study indicates that treating stable intertrochanteric fractures with unlocked long intramedullary nails may be an acceptable option, although further clinical study will be needed to test this assertion.
引用
收藏
页码:715 / 720
页数:6
相关论文
共 50 条
  • [1] Short or Long, Locked or Unlocked Nails for Intertrochanteric Fractures
    Maniar, Hemil H.
    Tawari, Akhil A.
    Mookerjee, Gaurav
    Horwitz, Daniel S.
    TECHNIQUES IN ORTHOPAEDICS, 2015, 30 (02) : 87 - 96
  • [2] Comparison between locked and unlocked intramedullary nails in intertrochanteric fractures
    Lanzetti R.M.
    Caraffa A.
    Lupariello D.
    Ceccarini P.
    Gambaracci G.
    Meccariello L.
    Manfreda F.
    Maiettini D.
    Vicente C.I.
    Scialpi M.
    Bisaccia O.
    Rinonapoli G.
    Bisaccia M.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (4) : 649 - 658
  • [3] Unlocked and locked elastic stable intramedullary nailing in an ovine tibia fracture model: A biomechanical study
    Berger, Leopold
    Fischerauer, Stefan
    Weiss, Barbara
    Celarek, Anna
    Castellani, Christoph
    Weinberg, Annelie-Martina
    Tschegg, Elmar
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 40 : 267 - 274
  • [4] Biomechanical evaluation of the risk of secondary fracture around short versus long cephalomedullary nails
    Daner III W.E.
    Owen J.R.
    Wayne J.S.
    Graves R.B.
    Willis M.C., Jr.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (8) : 1103 - 1108
  • [5] Unlocked versus dynamic and static distal locked femoral nails in stable and unstable intertrochanteric fractures. A prospective study
    Ciaffa, V.
    Vicenti, G.
    Mori, C. M.
    Panella, A.
    Conserva, V.
    Corina, G.
    Scialpi, L.
    Speciale, M.
    Fraccascia, A.
    Picca, G.
    Carrozzo, M.
    Leone, A.
    Morizio, A.
    Abate, A.
    Petrelli, L.
    Aloisi, A.
    Rollo, G.
    Filipponi, M.
    Freda, V.
    Pansini, A.
    Puce, A.
    De Gabriele, S.
    Solarino, G.
    Moretti, B.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 : S19 - S25
  • [6] Comparing Short Versus Long Cephalomedullary Nails for the Treatment of Intertrochanteric Hip Fractures
    Sobti, A.
    Sharma, S.
    Jameel, A.
    Nath, S.
    Balagopal, A.
    Jacob, J.
    Unnithan, A.
    BRITISH JOURNAL OF SURGERY, 2020, 107 : 130 - 130
  • [7] Distal locked or unlocked nailing for stable intertrochanteric fractures? A meta-analysis
    Yan, Wen-Shan
    Cao, Wei-Li
    Sun, Ming
    Ma, Deng-Yue
    Zhang, Peng
    ANZ JOURNAL OF SURGERY, 2020, 90 (1-2) : 27 - 33
  • [8] Biomechanical analysis of recently released cephalomedullary nails for trochanteric femoral fracture fixation in a human cadaveric model
    Pastor, Torsten
    Zderic, Ivan
    Gehweiler, Dominic
    Gardner, Michael J.
    Stoffel, Karl
    Richards, Geoff
    Knobe, Matthias
    Gueorguiev, Boyko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (12) : 3787 - 3796
  • [9] Short Versus Long Cephalomedullary Nails for Pertrochanteric Hip Fracture
    Frisch, Nicholas B.
    Nahm, Nickolas J.
    Khalil, Jad G.
    Les, Clifford M.
    Guthrie, Stuart T.
    Charters, Michael A.
    ORTHOPEDICS, 2017, 40 (02) : 83 - 88
  • [10] Lessons learned from biomechanical studies on cephalomedullary nails for the management of intertrochanteric fractures. A scoping review
    Mayor, Jorge
    Birgel, Vera
    Clausen, Jan-Dierk
    Aktas, Goekmen
    Sehmisch, Stephan
    Einfeldt, Ann-Kathrin
    Giannoudis, Vasilis
    Abdelaal, Ahmed H. K.
    Liodakis, Emmanouil
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (02):