Analysis of Copper Loss of Permanent Magnet Synchronous Motor With Formed Transposition Winding

被引:11
作者
Liang, Yanping [1 ]
Zhao, Fuchao [1 ]
Xu, Kangwen [1 ]
Wang, Weihao [1 ]
Liu, Jia [1 ]
Yang, Peipei [1 ]
机构
[1] Harbin Univ Sci & Technol, Coll Elect & Elect Engn, Harbin 150080, Peoples R China
来源
IEEE ACCESS | 2021年 / 9卷
基金
中国国家自然科学基金;
关键词
Windings; Permanent magnet motors; Synchronous motors; Copper; AC motors; Wires; Bars; Permanent magnet synchronous motor; formed transposition winding; hairpin winding; AC copper loss; EDDY-CURRENT LOSS; MACHINE;
D O I
10.1109/ACCESS.2021.3094833
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In recent years, the hairpin winding flat wire motor has received more and more attention because of its high power density and high torque, but the problem of increased AC copper loss caused by the increase of its wire diameter has restricted the use of the motor. Aiming at the problem of large AC copper loss in hairpin winding flat wire motors, this paper introduces the use of formed transposition windings into permanent magnet synchronous motors. Through analysis and comparison, the transposition bar suitable for permanent magnet synchronous motor is determined, and a method of inter-turn transposition that can improve the slot full rate of the motor is proposed. Taking a 223kW permanent magnet synchronous motor as an example, the transient field of the stator bar under 360 degrees transposition was calculated by using the field-circuit combined three-dimensional(3-D) finite element method. By calculating the data, combined with the AC copper loss calculation method of the formed transposition winding given in the article, the distribution of the DC copper loss, eddy current copper loss and circulating copper loss of the motor is obtained. Compared with hairpin windings, the use of formed transposition windings can reduce the AC copper loss of the motor to a certain extent, the feasibility of using the formed transposition winding in the permanent magnet synchronous motor is verified.
引用
收藏
页码:101105 / 101114
页数:10
相关论文
共 17 条
  • [11] Coupled 2-D and 3-D Eddy Current Analyses for Evaluating Eddy Current Loss of a Permanent Magnet in Surface PM Motors
    Okitsu, Takashi
    Matsuhashi, Daiki
    Gao, Yanhui
    Muramatsu, Kazuhiro
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (11) : 3100 - 3103
  • [12] Electrical Vehicles-Practical Solutions for Power Traction Motor Systems
    Popescu, Mircea
    Goss, James
    Staton, David Alan
    Hawkins, Douglas
    Chong, Yew Chuan
    Boglietti, Aldo
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (03) : 2751 - 2762
  • [13] Reddy Patel B., 2009, Proceedings of the 2009 IEEE Energy Conversion Congress and Exposition. ECCE 2009, P1919, DOI 10.1109/ECCE.2009.5316037
  • [14] Calculation of Ion-Flow Field Near the Crossing of HVdc Transmission Lines Using Equivalent Corona Conductors
    Wang, Donglai
    Lu, Tiebing
    Hao, Liming
    Zhang, Qian
    Chen, Bo
    Li, Xuebao
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (08)
  • [15] A New Global Transposition Method of Stator Winding and Its Loss Calculation in AC Machines
    Wang, Dongmei
    Liang, Yanping
    Gao, Lianlian
    Bian, Xu
    Wang, Chenguang
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2020, 35 (01) : 149 - 156
  • [16] Calculation of eddy current loss in axial field permanent-magnet machine with coreless stator
    Wang, RH
    Kamper, MJ
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (03) : 532 - 538
  • [17] Thermal Analysis and Management for Doubly Salient Brushless DC Generator With Flat Wire Winding
    Zhang, Jian
    Zhang, Zhuoran
    Xia, Yiwen
    Yu, Li
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2020, 35 (02) : 1110 - 1119