Background Prenatal diagnosis of placenta percreta (PP) is important to be able to provide effective management and a multidisciplinary approach to minimize the complications. Purpose To evaluate the role of shear-wave elastography (SWE) in the prenatal diagnosis of PP. Material and Methods A total of 18 women with PP and 20 pregnant women with normal placenta in the second or third trimesters were included in this prospective study. SWE was used to determine the elasticities of the placenta (in the maternal edge of the placenta) and myometrium. The obstetric data regarding grayscale and Doppler ultrasonography, and perinatal outcomes were reviewed. A mean placental SW velocity (SWV) cut-off value was determined to predict the presence of placental adherence. Results The SWV values of the PP group in the maternal edge of the placenta were significantly higher than those of the control group (1.95 +/- 0.19 m/s and 1.69 +/- 0.23 m/s; P = 0.001). Myometrial SWV was also higher in the PP group compared to the control group (2.25 +/- 0.39 m/s and 1.90 +/- 0.71 m/s; P = 0.002). A receiver operating characteristic (ROC) curve analysis was performed and the best cut-off value of placental SWV was determined as 1.92 m/s with sensitivity of 58% and specificity of 80%, to predict the placental adherence in patients with PP. Conclusion Placental stiffness was significantly higher in patients with PP than in pregnant women with normally localized placenta. Thus, we thought that SWE of the placenta might be used as an alternative method in the diagnosis of PP.
引用
收藏
页码:424 / 430
页数:7
相关论文
共 50 条
  • [41] STIFFNESS AND ANISOTROPY EFFECT ON SHEAR WAVE ELASTOGRAPHY: A PHANTOM AND IN VIVO RENAL STUDY
    Leong, Sook Sam
    Wong, Jeannie Hsiu Ding
    Shah, Mohammad Nazri Md
    Vijayananthan, Anushya
    Jalalonmuhali, Maisarah
    Sharif, Nur Hidayati Mohd
    Abas, Nurul Khairyah
    Ng, Kwan Hoong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (01): : 34 - 45
  • [42] Supersonic shear-wave elastography and APRI for the detection and staging of liver disease in pediatric cystic fibrosis
    Calvopina, Diego A.
    Noble, Charlton
    Weis, Anna
    Hartel, Gunter F.
    Ramm, Louise E.
    Balouch, Fariha
    Fernandez-Rojo, Manuel A.
    Coleman, Miranda A.
    Lewindon, Peter J.
    Ramm, Grant A.
    JOURNAL OF CYSTIC FIBROSIS, 2020, 19 (03) : 449 - 454
  • [43] Is Shear-Wave Elastography a Clinical Severity Indicator of Myofascial Pain Syndrome? An Observational Study
    Valera-Calero, Juan Antonio
    Sanchez-Jorge, Sandra
    Buffet-Garcia, Jorge
    Varol, Umut
    Gallego-Sendarrubias, Gracia Maria
    Alvarez-Gonzalez, Javier
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [44] Shear-wave elastography of the ulnar collateral ligament of the elbow in healthy volunteers: a pilot study
    Gupta, Nakul
    Labis, John S.
    Harris, Joshua
    Trakhtenbroit, Michael A.
    Peterson, Leif E.
    Jack, Robert A., II
    McCulloch, Patrick C.
    SKELETAL RADIOLOGY, 2019, 48 (08) : 1241 - 1249
  • [45] Diffusion-Weighted MRI-Based Virtual Elastography and Shear-Wave Elastography for the Assessment of Breast Lesions
    Sun, Kun
    Zhu, Ying
    Chai, Weimin
    Zhu, Hong
    Fu, Caixia
    Zhan, Weiwei
    Yan, Fuhua
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (05) : 2207 - 2213
  • [46] Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer
    Ahmad, Sarfraz
    Cao, Rui
    Varghese, Tomy
    Bidaut, Luc
    Nabi, Ghulam
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (09): : 3280 - 3287
  • [47] 3D Global Time-Delay Estimation for Shear-Wave Absolute Vibro-Elastography of the Placenta
    Hashemi, Hoda S.
    Honarvar, Mohammad
    Salcudean, Tim
    Rohling, Robert
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2079 - 2083
  • [48] CHARACTERIZATION OF SUSPICIOUS MICROCALCIFICATIONS ON MAMMOGRAPHY USING 2D SHEAR-WAVE ELASTOGRAPHY
    Kayadibi, Y. A. S. E. M. I. N.
    Ucar, N. E. S. E.
    Kaya, Mehmet Fatih
    Yildirim, E. M. I. N. E.
    Bektas, S. I. B. E. L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (09): : 2532 - 2542
  • [49] Reliability of Shear-Wave Elastography Estimates of the Young Modulus of Tissue in Follicular Thyroid Neoplasms
    Anvari, Arash
    Dhyani, Manish
    Stephen, Antonia E.
    Samir, Anthony E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (03) : 609 - 616
  • [50] Quantitative Assessment of Thyroid, Submandibular, and Parotid Glands Elasticity With Shear-Wave Elastography in Children
    Habibi, Hatice Arioz
    Durmaz, Emine Sebnem Memis
    Qarayeva, Vusale
    Kandemirli, Sedat Giray
    Ucar, Ayse Kalyoncu
    Aslan, Mine
    Apaydin, Gozde
    Kurugoglu, Sebuh
    Adaletli, Ibrahim
    ULTRASOUND QUARTERLY, 2018, 34 (02) : 58 - 61