Aerosol desolvation studies with a thermospray nebulizer coupled to inductively coupled plasma atomic emission spectrometry

被引:17
作者
Mora, J [1 ]
Todolí, JL [1 ]
Rico, I [1 ]
Canals, A [1 ]
机构
[1] Univ Alicante, Fac Ciencias, Dept Quim Analit, E-03080 Alicante, Spain
关键词
thermospray; aerosol desolvation; analyte transport rate; solvent transport rate; inductively coupled plasma atomic emission spectrometry;
D O I
10.1039/a801334i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
TWO desolvation systems commonly used in ICP-AES have been evaluated when coupled to a thermospray nebulizer, The desolvation systems are: (i) a thermostated spray chamber (TSC) and, (ii) a two-unit desolvation system (TUDS) in which the first unit is a heated single-pass spray chamber and the second one is a Liebig condenser. Both systems were evaluated with aqueous and organic solutions. The temperature of the chamber in the TSC (-5 to 20 degrees C) and the temperatures of the heated spray chamber (60 to 140 degrees C) and the condenser (-5 to 20 degrees C) in the TUDS were taken as variables. To e evaluate the effect of these variables on the performance of the desolvation systems, drop size distribution of the tertiary aerosol, solvent and analyte transport rates and emission signal have been measured. Under optimal desolvation conditions, the values of the solvent transport efficiencies were similar for both systems, ranging from 2.3 to 9.5%. Analyte transport efficiency values ranged from 36 to 77% and from 5 to 8% for TUDS and TSC, respectively. TUDS gives rise to higher signals (6 to 7 fold higher) and lower LOD (2 to 11 times lower) than TSC, As regards the solvent nature, the highest emission intensity and lower LOD are obtained with ethanol, followed by water and butan-1-ol, The LOD values obtained with the combination thermospray-TUDS are 2 to 26 times lower than those obtained with a conventional pneumatic nebulizer coupled to the same desolvation system.
引用
收藏
页码:1229 / 1234
页数:6
相关论文
共 27 条
[1]   A microwave powered thermospray nebulizer for liquid sample introduction in inductively coupled plasma atomic emission spectrometry [J].
Bordera, L ;
Todoli, JL ;
Mora, J ;
Canals, A ;
Hernandis, V .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3578-3586
[2]   EFFECT OF ANALYTE AND SOLVENT TRANSPORT ON SIGNAL INTENSITIES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
BROWNER, RF ;
CANALS, A ;
HERNANDIS, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (05) :659-673
[3]   DIAGNOSTIC STUDIES ON DESOLVATED AEROSOLS FROM ULTRASONIC NEBULIZERS [J].
CLIFFORD, RH ;
SOHAL, P ;
LIU, HY ;
MONTASER, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (09) :1107-1122
[4]  
CONVER TS, 1997, SPECTROCHIM ACTA B, V52, P1807
[5]   MATRIX INTERFERENCES OBSERVED WITH A THERMOSPRAY SAMPLE INTRODUCTION SYSTEM FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
DELOOSVOLLEBREGT, MTC ;
PENG, RZ ;
TIGGELMAN, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :165-168
[6]   THE PERFORMANCE OF A LOW CONSUMPTION THERMOSPRAY NEBULIZER FOR SPECIFIC USE IN MICRO-HPLC AND GENERAL USE IN FI WITH ICP-AES DETECTION [J].
ELGERSMA, JW ;
BALKE, J ;
MAESSEN, FJMJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (6-7) :1073-1088
[7]   Behaviour of a desolvation system based on microwave radiation heating for use in inductively coupled plasma atomic emission spectrometry [J].
Gras, L ;
Mora, J ;
Todoli, JL ;
Hernandis, V ;
Canals, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (08) :1201-1213
[8]  
HINDS WC, 1988, AEROSOL TECHNOLOGY
[9]   THERMOSPRAY SAMPLE INTRODUCTION TO ATOMIC SPECTROMETRY [J].
KOROPCHAK, JA ;
VEBER, M .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (03) :113-141
[10]   INFLUENCE OF WATER ON CONDITIONS IN THE INDUCTIVELY COUPLED ARGON PLASMA [J].
LONG, SE ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (12) :1461-1471