Indoor Air Quality Assessments in Educational Facilities in Saudi Arabia: A Systematic Review

被引:0
作者
Alama, Areej [1 ]
Sabbagh, Mostafa [2 ]
机构
[1] Dar Al Hekma Univ, Fac Design & Architecture, Jeddah, Saudi Arabia
[2] King Abdulaziz Univ, Fac Architecture & Planning, Jeddah, Saudi Arabia
来源
JOURNAL OF ARCHITECTURE AND PLANNING -KING SAUD UNIVERSITY | 2021年 / 33卷 / 04期
关键词
Indoor Air Quality; indoor air pollutant; CO2; concentration; particulate matter; heavy metals; contamination; thermal comfort; educational facility; POLYCYCLIC AROMATIC-HYDROCARBONS; HUMAN HEALTH; EXPOSURE; SCHOOLS; PARTICULATE; PERFORMANCE; POLLUTANTS; POLLUTION; DAMMAM; PAHS;
D O I
10.33948/JAP-KSU-33-4-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor Air Quality (IAQ) assessments conducted in classrooms in hot arid regions differ greatly from cases found in the general literature due to variations in sociocultural context, climatic conditions, building design, and operation. This paper aims to create a systematic review on IAQ of educational buildings in the Kingdom of Saudi Arabia (KSA) within the past 25 years, identify pollution risks, and indicate gaps in investigations. The review covers a collection of IAQ indices from subjective investigations, experimental studies, simulation work, physical environmental measurements, and statistical analysis from multi-disciplinary fields to introduce a holistic overview. This review is significant since investigations for such context with complete reliance on mechanical air-conditioning (AC), are limited in number and level of details. Using PRISMA guidelines, 17 original studies were found to fit the review criterion; some were unique in terms of examined variables. Among the reviewed studies, classroom CO2 concentrations and some of the measured indoor air pollutants were significantly higher than the values recommended by reference standards. Serious health risks and bacterial contaminations were associated with poor AC systems and inefficient ventilation. Implementation of practical guidelines is recommended to mitigate indoor environmental issues in classrooms and reduce their physical and psychological impact on occupants.
引用
收藏
页码:423 / 441
页数:19
相关论文
共 52 条
[1]  
Ahmed G., 2017, THESIS UCL
[2]  
Ahmed R. J., 2018, INT BUILD PHYS C, V5, DOI [10.14305/ibpc.2018.ie-1.05, DOI 10.14305/IBPC.2018.IE-1.05]
[3]  
Al Mijalli SH, 2017, Air Water Borne Dis, V6, P1
[4]   Seasonal variation of indoor radon concentration in a desert climate [J].
Al-Khateeb, H. M. ;
Nuseirat, M. ;
Aljarrah, K. ;
Al-Akhras, M. -Ali. H. ;
Bani-Salameh, H. .
APPLIED RADIATION AND ISOTOPES, 2017, 130 :49-53
[5]   Exploring thermal comfort experience and adaptive opportunities of female and male high school students [J].
Al-Khatri, Hanan ;
Alwetaishi, Mamdooh ;
Gadi, Mohamed B. .
JOURNAL OF BUILDING ENGINEERING, 2020, 31 (31)
[6]  
Al-Rehaili A., 1999, WIT T ECOLOGY ENV, V37
[7]  
Al-Rehaili A, 1999, WIT T BUILT ENV, V44
[8]   Outdoor-indoor air quality in Riyadh:: SO2, NH3, and HCHO [J].
Al-Rehaili, AM .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2002, 79 (03) :287-300
[9]  
Al-Suhaili I., 2015, J ENV SCI ENG, P451, DOI [DOI 10.17265/2162-5263/2015.08.006, 10.17265/2162-5263/2015.08, DOI 10.17265/2162-5263/2015.08]
[10]  
Al-Sulaihi I. A., 2015, C SCI COOP WORKSH EN