Corneal biomechanical changes after corneal cross-linking in patients with keratoconus

被引:3
作者
Hamid, Adel [1 ]
Jahadi-Hosseini, Hamidreza [1 ]
Khalili, Mohammad Reza [1 ]
Jahanbani-Ardakani, Hamidreza [1 ,2 ]
机构
[1] Shiraz Univ Med Sci, Poostchi Ophthalmol Res Ctr, Sch Med, Dept Ophthalmol, Shiraz, Iran
[2] Shiraz Univ Med Sci, Poostchi Ophthalmol Res Ctr, Zand St, Shiraz, Iran
关键词
Corneal biomechanical properties; Corneal cross-linking; CorVis ST; Dynamic imaging; Keratoconus; ABNORMALITIES; ULTRAVIOLET; RIBOFLAVIN;
D O I
10.4103/joco.joco_177_21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the changes in biomechanical properties of the cornea using the Corvis ST device after the treatment of keratoconus patients with ultraviolet-A/riboflavin corneal cross-linking (CXL).Methods: Thirty-seven eyes from 37 consecutive patients with progressive keratoconus were included in this prospective observational case series. Corneal biomechanical parameters including the length of the applanated cornea (L1 and L2), corneal movement velocity during applanation (V1 and V2) at the moment of the first and second applanation, deformation amplitude (DA), distance between bending points of the cornea points of the cornea (PD), and concave radius of curvature (R) at the point of the highest concavity were recorded using the Corvis ST at baseline, 3 months, and 1 year after CXL.Results: The mean age of the patients was 23.27 years (range, 19-31 years). Among CorVis ST corneal biomechanical parameters, L1, DA, PD, and R at the point of the highest concavity did not change significantly. The length of the applanated cornea at the moment of second applanation (L2) showed a significant change 3 months after CXL, but no significant difference was found between the 3-month and 1-year values of this parameter. Corneal movement velocity during applanation (V1 and V2) did not change 3 months after doing CXL, but the changes in these parameters were significant 1 year after CXL. Conclusions: Although the CorVis ST device may detect changes in some biomechanical properties of cornea after the treatment of keratoconus patients with CXL, many parameters remain unchanged, and this device cannot readily be used to find the effects of CXL.
引用
收藏
页码:409 / 413
页数:5
相关论文
共 29 条
[1]   Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based Tonometer [J].
Ali, Noor Q. ;
Patel, Dipika V. ;
McGhee, Charles N. J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) :3651-3659
[2]   BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS [J].
ANDREASSEN, TT ;
SIMONSEN, AH ;
OXLUND, H .
EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) :435-441
[3]   Dynamic Scheimpflug-based Assessment of Keratoconus and the Effects of Corneal Cross-linking [J].
Bak-Nielsen, Sashia ;
Pedersen, Iben B. ;
Ivarsen, Anders ;
Hjortdal, Jesper .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) :408-414
[4]  
EDMUND C, 1988, ACTA OPHTHALMOL, V66, P134
[5]  
Elham R, 2017, J CURR OPHTHALMOL, V29, P175, DOI 10.1016/j.joco.2017.05.002
[6]   Topographic, Corneal Wavefront, and Refractive Outcomes 2 Years After Collagen Crosslinking for Progressive Keratoconus [J].
Ghanem, Ramon C. ;
Santhiago, Marcony R. ;
Berti, Thais ;
Netto, Marcelo V. ;
Ghanem, Vinicius C. .
CORNEA, 2014, 33 (01) :43-48
[7]   Higher-order aberrations after corneal collagen crosslinking for keratoconus and corneal ectasia [J].
Greenstein, Steven A. ;
Fry, Kristen L. ;
Hersh, Matthew J. ;
Hersh, Peter S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02) :292-302
[8]   Corneal Collagen Cross-linking with Riboflavin and Ultraviolet A Irradiation for Keratoconus Long-term Results [J].
Hashemi, Hassan ;
Seyedian, Mohammad Amin ;
Miraftab, Mohammad ;
Fotouhi, Akbar ;
Asgari, Soheila .
OPHTHALMOLOGY, 2013, 120 (08) :1515-1520
[9]   Corneal Deformation Measurement Using Scheimpflug Noncontact Tonometry [J].
Hon, Ying ;
Lam, Andrew K. C. .
OPTOMETRY AND VISION SCIENCE, 2013, 90 (01) :E1-E8
[10]   Corneal biomechanical outcome of collagen cross-linking in keratoconic patients evaluated by Corvis ST [J].
Jabbarvand, Mahmoud ;
Moravvej, Zahra ;
Shahraki, Kianoush ;
Hashemian, Hessam ;
Ghasemi, Hamed ;
Berijani, Sahar ;
Amiri, Zahra ;
Jamali, Alireza .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) :1577-1583