Power profiles in multifocal contact lenses with variable multifocal zone

被引:10
作者
Monsalvez-Romin, Daniel [1 ]
Dominguez-Vicent, Alberto [1 ]
Garcia-Lazaro, Santiago [1 ]
Esteve-Taboada, Jose J. [1 ]
Cervino, Alejandro [1 ]
机构
[1] Univ Valencia, Dept Opt & Optometry & Vis Sci, Optometry Res Grp, Valencia, Spain
关键词
contact lenses; lens fitting; power profile; RGP multifocal lenses; variable addition designs; VISION;
D O I
10.1111/cxo.12575
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundThe power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. MethodsThe measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a function of the aperture radius was described in terms of radial computed colour maps, radial averaged power profiles, addition, and lens portion used for near vision. ResultsThe amount of total addition achieved depends on the diameter of the distance-vision area. That is, the bigger the distance vision area, the bigger the radius of the lens in order to get the same level of addition. In other words, the XS lens provides higher addition values compared to the XL lens design for a given aperture. ConclusionsThe XS and S designs seem to be aimed to favour near vision, whereas the L and XL designs seem to favour distance vision. For this reason, patients who demand good distance vision might benefit from the L or XL designs, and those with high demand on near-vision tasks might benefit from the XS or S designs. The M design could be the best option for those patients who have the same needs for distance and near vision.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 2006, ISO183693
[2]   In vitro power profiles of daily disposable contact lenses [J].
Belda-Salmeron, Lurdes ;
Madrid-Costa, David ;
Ferrer-Blasco, Teresa ;
Garcia-Lazaro, Santiago ;
Montes-Mico, Robert .
CONTACT LENS & ANTERIOR EYE, 2013, 36 (05) :247-252
[3]   Topography-Based Rigid Gas Permeable Lens Fitting in Normal Corneas: The Relevance of Eyelid and Tear Film Attributes [J].
Cardona, Genis ;
Isern, Roser .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (06) :359-364
[4]  
Conoptica, MULTILIFE LENT PERM
[5]   Repeatability of in vitro power profile measurements for multifocal contact lenses [J].
Dominguez-Vicent, Alberto ;
Marin-Franch, Ivan ;
Juan Esteve-Taboada, Jose ;
Madrid-Costa, David ;
Montes-Mico, Robert .
CONTACT LENS & ANTERIOR EYE, 2015, 38 (03) :168-172
[6]  
Donshik P C, 1996, Trans Am Ophthalmol Soc, V94, P135
[7]   Trends in US Contact Lens Prescribing 2002 to 2014 [J].
Efron, Nathan ;
Nichols, Jason J. ;
Woods, Craig A. ;
Morgan, Philip B. .
OPTOMETRY AND VISION SCIENCE, 2015, 92 (07) :758-767
[8]   Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic [J].
Ferrer-Blasco, Teresa ;
Gonzalez-Meijome, Jose Manuel ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :424-432
[9]   Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions [J].
Garcia-Lazaro, Santiago ;
Ferrer-Blasco, Teresa ;
Madrid-Costa, David ;
Albarran-Diego, Cesar ;
Montes-Mico, Robert .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (01) :19-24
[10]  
ISO, 2012, ISO183692