Axillary nerve monitoring during arthroscopic shoulder stabilization

被引:18
作者
Esmail, AN
Getz, CL
Schwartz, DM
Wierzbowski, L
Ramsey, ML
Williams, GR
机构
[1] Univ Penn, Dept Orthopaed Surg, Shoulder & Elbow Serv, Philadelphia, PA 19104 USA
[2] Surg Monitoring Associates, Bala Cynwyd, PA USA
[3] Kaiser Permanente, Dept Orthopaed Surg, Panorama City, CA USA
关键词
nerve; injury; monitoring; capsulorrhaphy; thermal; axillary;
D O I
10.1016/j.arthro.2005.03.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study evaluated the ability of a novel intraoperative neurophysiologic monitoring method used to locate the axillary nerve, predict relative capsule thickness, and identify impending injury to the axillary nerve during arthroscopic thermal capsulorrhaphy of the shoulder. Type of Study: Prospective cohort study. Methods: Twenty consecutive patients with glenohumeral instability were monitored prospectively during arthroscopic shoulder surgery. Axillary nerve mapping and relative capsule thickness estimates were recorded before the stabilization portion of the procedure. During labral repair and/or thermal capsulorrhaphy, continuous and spontaneous electromyography recorded nerve activity. In addition, trans-spinal motor-evoked potentials of the fourth and fifth cervical roots and brachial plexus electrical stimulation, provided real-time information about nerve integrity. Results: Axillary nerve mapping and relative capsule thickness were recorded in all patients. Continuous axillary nerve monitoring was successfully performed in all patients. Eleven of the 20 patients underwent thermal capsulorrhaphy alone or in combination with arthroscopic labral repair. Nine patients underwent arthroscopic labral repair alone. In 4 of the 11 patients who underwent thermal capsulorrhaphy, excessive spontaneous neurotonic electromyographic activity was noted, thereby altering the pattern of heat application by the surgeon. In 1 of these 4 patients, a small increase in the motor latency was noted after the procedure but no clinical deficit was observed. There were no neuromonitoring or clinical neurologic changes observed in the labral repair group without thermal application. At last follow-up, no patient in either group had any clinical evidence of nerve injury or complications from neurophysiologic monitoring. Conclusions: We successfully evaluated the use of intraoperative nerve monitoring to identify axillary nerve position, capsule thickness, and provide real-time identification of impending nerve injury and function during shoulder thermal capsulorrhaphy. The use of intraoperative nerve monitoring altered the heat application technique in 4 of 11 patients and may have prevented nerve injury. Level of Evidence: Level II, prospective cohort study.
引用
收藏
页码:665 / 671
页数:7
相关论文
共 12 条
  • [1] THE AXILLARY NERVE AND ITS RELATIONSHIP TO COMMON SPORTS MEDICINE SHOULDER PROCEDURES
    BRYAN, WJ
    SCHAUDER, K
    TULLOS, HS
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (02) : 113 - 116
  • [2] Arthroscopic electrothermal surgery of the shoulder
    Fanton, GS
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 1998, 6 (03) : 139 - 146
  • [3] Effect of selective capsulorrhaphy on the passive range of motion of the glenohumeral joint
    Gerber, C
    Werner, CML
    Macy, JC
    Jacob, HAC
    Nyffeler, RW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (01) : 48 - 55
  • [4] Axillary nerve temperatures during radiofrequency capsulorrhaphy of the shoulder
    Gryler, EC
    Greis, PE
    Burks, RT
    West, J
    [J]. ARTHROSCOPY, 2001, 17 (06): : 567 - 572
  • [5] Thermal capsulorrhaphy treatment of shoulder instability - Basic science
    Hayashi, K
    Markel, MD
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (390) : 59 - 72
  • [6] Monopolar radiofrequency energy effects on joint capsular tissue: Potential treatment for joint instability - An in vivo mechanical, morphological, and biochemical study using an ovine model
    Hecht, P
    Hayashi, K
    Lu, Y
    Fanton, GS
    Thabit, G
    Vanderby, R
    Markel, MD
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (06) : 761 - 771
  • [7] The thermal effect of monopolar radiofrequency energy on the properties of joint capsule - An in vivo histologic study using a sheep model
    Hecht, P
    Hayashi, K
    Cooley, AJ
    Lu, Y
    Fanton, GS
    Thabit, G
    Markel, MD
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (06) : 808 - 814
  • [8] Neurologic complications of surgery for anterior shoulder instability
    Ho, E
    Cofield, RH
    Balm, MR
    Hattrup, SJ
    Rowland, CM
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 1999, 8 (03) : 266 - 270
  • [9] LOOMER R, 1989, CLIN ORTHOP RELAT R, P100
  • [10] Tissue shrinkage with the Holmium:Yttrium aluminum garnet laser - A postoperative assessment of tissue length, stiffness, and structure
    Schaefer, SL
    Ciarelli, MJ
    Arnoczky, SP
    Ross, HE
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1997, 25 (06) : 841 - 848