A direct comparison of patient and force-controlled simulator total knee replacement kinematics

被引:47
作者
DesJardins, John D.
Banks, Scott A.
Benson, Lisa C.
Pace, Thomas
LaBerge, Martine
机构
[1] Clemson Univ, Dept Bioengn, Clemson, SC 29634 USA
[2] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Orthopaed & Rehabil, Gainesville, FL 32611 USA
[4] Carolina Orthopaed Ctr, Greenville, SC 29615 USA
基金
美国国家科学基金会;
关键词
total knee replacement kinematics; patient functional activity; total knee replacement simulator; ISO walking cycle standards; UHMWPE wear testing simulation; force-con trolled simulation;
D O I
10.1016/j.jbiomech.2007.05.022
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The need to critically evaluate the efficacy of current total knee replacement (TKR) wear testing methodologies is great. Proposed international standards for TKR wear simulation have been drafted, yet their methods continue to be debated. The "gold standard" to which all TKR wear testing methodologies should be compared is measured in vivo TKR performance in patients. The current study compared patient TKR kinematics from fluoroscopic analysis and simulator TKR kinematics from force-controlled wear testing to quantify similarities in clinical ranges of motion and contact bearing kinematics and to evaluate the proposed ISO force-controlled wear testing methodology. The treadmill walking kinematics from eight well-functioning, 13 month average post-op patients were compared to the 2 million cycle interval walking cycle kinematics from a force-controlled (Instron/Stanmore Knee Joint Simulator, Instron, Canton, MA) knee simulator using identical implant designs (Natural Knee II, Standard Congruent, Zimmer, Warsaw, IN). The in vivo and simulator data showed good agreement in kinematic patterns and ranges of clinical motion. Tribologically the data sets showed similar contact pathway ranges of motion and wear travel distances per cycle. Surgical and simulator alignments of the implant systems were determined to be a contributing factor in observed kinematic differences. This study's statistical findings offer supporting evidence that the simulation of in vivo walking cycle wear kinematics can be accurately reproduced with a force controlled testing methodology. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3458 / 3466
页数:9
相关论文
共 39 条
  • [1] Banks S A, 1997, Am J Knee Surg, V10, P261
  • [2] Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    Banks, SA
    Hodge, WA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) : 638 - 649
  • [3] Investigation of wear of knee prostheses in a new displacement/force-controlled simulator
    Barnett, PI
    McEwen, HMJ
    Auger, DD
    Stone, MH
    Ingham, E
    Fisher, J
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) : 51 - 61
  • [4] Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics
    Benson, LC
    DesJardins, JD
    LaBerge, M
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05): : 496 - 504
  • [5] Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator
    Benson, LC
    DesJardins, JD
    Harman, MK
    LaBerge, M
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H6) : 409 - 418
  • [6] BENSON LC, 2002, P 48 ANN M ORTH RES, V26, P1006
  • [7] BEVILACQUA A, 1998, EFFECT TIBIAL TRAY M
  • [8] Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses
    Blunn, GW
    Joshi, AB
    Minns, RJ
    Lidgren, L
    Lilley, P
    Ryd, L
    Engelbrecht, E
    Walker, PS
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (03) : 281 - 290
  • [9] BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
  • [10] DENNIS D, 2001, 47 ANN M ORTH RES SO, P821