Heating performance comparison of R410A and its substitutions in air-to-water heat pumps with vapor injection

被引:17
作者
Chen, Xiaoning [1 ]
Yang, Jingye [1 ]
Liu, Cichong [1 ]
Chen, Jiangping [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Room 420,M&E Bldg A 800, Shanghai 200240, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2018年 / 96卷
关键词
Vapor injection; Heat pump; Injection ratio; R410A substitutions; CONDITIONING SYSTEMS; SCROLL COMPRESSOR; R32; R1234YF;
D O I
10.1016/j.ijrefrig.2018.09.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
R410A has been widely applied in air-to-water heat pumps for space heating, but its phase-out process is accelerated due to the high GWP. This paper investigates the heating performances of low GWP HFO mixtures (R452B and R447B) as substitutions in a sub-cooler vapor injection cycle. The results illustrate that the capacities of R452B and R447B systems are lower by 0.7-5% and 6-15% in the measured conditions, respectively. The attenuation with the ambient temperature of R452B is slower than that of R410A, while R447B is faster. The COP improvements of R452B are 4-9% and 1.4-2.4% with and without vapor injection, respectively. The COP increases of R447B are 3-12% and 0.4-3.8% with and without vapor injection, respectively. In view of injection characteristics, the optimal injection pressure ratios of R452B and R447B are slightly higher. Synthetically R452B and R447B perform more excellent in the high outlet water temperature conditions and R452B is also suitable for low ambient temperatures. (C) 2018 Published by Elsevier Ltd.
引用
收藏
页码:78 / 87
页数:10
相关论文
共 21 条
[1]   Testing, simulation and soft-optimization of R410A low-GWP alternatives in heat pump system [J].
Alabdulkarem, Abdullah ;
Eldeeb, Radia ;
Hwang, Yunho ;
Aute, Vikrant ;
Radermacher, Reinhard .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 :106-117
[2]  
Barve A., 2012, INT REFR AIR COND C
[3]  
CHPA, 2017, REP DEV AIR SOURC HE
[4]   Comparison of the heating performance of air-source heat pumps using various types of refrigerant injection [J].
Heo, Jaehyeok ;
Jeong, Min Woo ;
Baek, Changhyun ;
Kim, Yongchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (02) :444-453
[5]   Partial load performance test of residential heat pump system with low-GWP refrigerants [J].
In, Sungjin ;
Cho, Keumnam ;
Lim, Byunghan ;
Lee, Changseon .
APPLIED THERMAL ENGINEERING, 2015, 85 :179-187
[6]   Refrigerant R32 as lower GWP working fluid in residential air conditioning systems in Europe and the USA [J].
Mota-Babiloni, Adrian ;
Navarro-Esbri, Joaquin ;
Makhnatch, Pavel ;
Moles, Francisco .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 80 :1031-1042
[7]  
Naldi C., 2015, P IBPS IT C BUILD SI
[8]   R1234yf and R1234ze(E) as low-GWP refrigerants for residential heat pump water heaters [J].
Nawaz, Kashif ;
Shen, Bo ;
Elatar, Ahmed ;
Baxter, Van ;
Abdelaziz, Omar .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 :348-365
[9]  
Noboru K., 2011, INT J REFRIG, V34, P275
[10]   An experimental and theoretical study on an injection-assisted air-conditioner using R32 in the refrigeration cycle [J].
Qv, Dehu ;
Dong, Bingbing ;
Cao, Lin ;
Ni, Long ;
Wang, Jijin ;
Shang, Runxin ;
Yao, Yang .
APPLIED ENERGY, 2017, 185 :791-804