Quantification of Optic Nerve and Sheath Diameter by Transorbital Sonography: A Systematic Review and Metanalysis

被引:37
作者
Schroeder, Christoph [1 ]
Katsanos, Aristeidis H. [1 ,2 ,3 ]
Richter, Daniel [1 ]
Tsivgoulis, Georgios [3 ,4 ]
Gold, Ralf [1 ]
Krogias, Christos [1 ]
机构
[1] Ruhr Univ, St Josef Hosp, Dept Neurol, Bochum, Germany
[2] McMaster Univ, Populat Hlth Res Inst, Dept Neurol, Hamilton, ON, Canada
[3] Natl & Kapodistrian Univ Athens, Attikon Hosp, Sch Med, Dept Neurol 2, Athens, Greece
[4] Univ Tennessee, Ctr Hlth Sci, Dept Neurol, Memphis, TN 38163 USA
关键词
Transorbital sonography; optic nerve diameter; optic nerve sheath diameter; metanalysis; IDIOPATHIC INTRACRANIAL HYPERTENSION; PRESSURE; ULTRASOUND; DIAGNOSIS; ULTRASONOGRAPHY; PROGNOSTICATION; RELIABILITY; NEURITIS; AXIS;
D O I
10.1111/jon.12691
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE To date, normal values for optic nerve diameter (OND) and optic nerve sheath diameter (ONSD) for transorbital sonography (TOS) have only been reported by individual small-scale studies, exposing a great variability in the measurement of the OND and ONSD. METHODS We performed a systematic review and metanalysis of available to date studies on TOS evaluation of adults without elevated intracranial pressure to provide an overview of the published literature, measuring methods and further specify normal values for OND and ONSD. RESULTS In total, we included 39 studies with 2,927 healthy volunteers (mean age 36.1 years, 44.4% female), so that a total of 5,854 eyes were examined. All pooled analyses were based on random effect models. Mean values for OND were provided in 13 studies. Calculated mean pooled OND value was 3.08 mm (95% confidence interval [CI], 2.9-3.25), with low heterogeneity across studies (I-2 = 12.7%). Thirty-four studies provided mean values for ONSD measurement. The pool of mean ONSD measurements was 4.78 mm (95% CI, 4.63-4.94), with evidence of substantial heterogeneity between estimates ONSD (I-2 = 50.6%). There were no significant differences (P = .139) in the subsequent subgroup analysis for the different geographic continents. Also, no significant differences could be recorded for the effect of age (P = .824) or gender (P = .093). CONCLUSIONS TOS is a frequently described and widely used method. We provide reference values of OND and ONSD that are based on metanalytical analysis. Different measuring methods of ONSD result in higher heterogeneity. Subgroup analysis revealed no significant correlation between ONSD and age, gender, or geographic origin.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 65 条
[1]   Optic nerve sonography: A noninvasive means of detecting raised intracranial pressure in a resource-limited setting [J].
Aduayi, Olufunso Simisola ;
Asaleye, Christianah Mopelola ;
Adetiloye, Victor Adebayo ;
Komolafe, Edward Oluwole ;
Aduayi, Victor Adovi .
JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2015, 6 (04) :563-567
[2]   Coronal Axis Measurement of the Optic Nerve Sheath Diameter Using a Linear Transducer [J].
Amini, Richard ;
Stolz, Lori A. ;
Patanwala, Asad E. ;
Adhikari, Srikar .
JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (09) :1607-1612
[3]  
Anas I, 2014, MALAYS J MED SCI, V21, P24
[4]  
Asghar A, 2015, ANAESTH PAIN INTENSI, V19, P282
[5]   Enlarged Optic Nerve Sheath in Aneurysmal Subarachnoid Hemorrhage despite Normal Intracranial Pressure [J].
Baeuerle, Jochen ;
Niesen, Wolf-Dirk ;
Egger, Karl ;
Buttler, Klaus-Juergen ;
Reinhard, Matthias .
JOURNAL OF NEUROIMAGING, 2016, 26 (02) :194-196
[6]   Intra- and Interobsever Reliability of Sonographic Assessment of the Optic Nerve Sheath Diameter in Healthy Adults [J].
Baeuerle, Jochen ;
Lochner, Piergiorgio ;
Kaps, Manfred ;
Nedelmann, Max .
JOURNAL OF NEUROIMAGING, 2012, 22 (01) :42-45
[7]   Sonographic assessment of the optic nerve sheath in idiopathic intracranial hypertension [J].
Baeuerle, Jochen ;
Nedelmann, Max .
JOURNAL OF NEUROLOGY, 2011, 258 (11) :2014-2019
[8]  
Ballantyne S A, 2002, Eur J Ultrasound, V15, P145, DOI 10.1016/S0929-8266(02)00036-8
[9]  
BAUERLE J, 2013, BMC NEUROL, V13
[10]   THE APPLICATION OF ULTRASONICS LOCATING TECHNIQUES TO OPHTHALMOLOGY - THEORETIC CONSIDERATIONS AND ACOUSTIC PROPERTIES OF OCULAR MEDIA .1. REFLECTIVE PROPERTIES [J].
BAUM, G ;
GREENWOOD, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1958, 46 (05) :319-329