Conventional Linear Criteria with Sample Entropy in the Interpretation of Reactive Antepartum Fetal Heart Rate Tracings

被引:4
作者
Park, Young-Sun [3 ,4 ]
Hoh, Jeong-Kyu [1 ]
Koh, Seung-Kwon [1 ]
Shin, Jinho [2 ]
Park, Moon-Il [1 ]
机构
[1] Hanyang Univ, Coll Med, Dept Obstet & Gynecol, Seoul 133792, South Korea
[2] Hanyang Univ, Coll Med, Dept Cardiol, Seoul 133792, South Korea
[3] Hanyang Univ, Dept Math, Seoul 133792, South Korea
[4] Hanyang Univ, Res Inst Nat Sci, Seoul 133792, South Korea
关键词
Fetal heart rate; Nonreactive tests; Vibroacoustic stimulation test; Approximate entropy; Sample entropy; GROWTH RESTRICTED FETUSES; TIME-SERIES ANALYSIS; APPROXIMATE ENTROPY; BEHAVIORAL STATES; GESTATIONAL-AGE; RATE PARAMETERS; NONSTRESS TEST; RATE DYNAMICS; RATE PATTERNS; PREDICTION;
D O I
10.1159/000314907
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To compare the test duration times and rate of nonreactive results between the conventional linear reactive criteria (CLRC) and the modified nonlinear reactive criteria (MNRC) in electronic fetal heart rate (FHR) monitoring. The MNRC are the CLRC with the addition of approximate entropy or sample entropy. Methods: One thousand women with singleton pregnancies between 30 and 37 weeks' gestation were selected. They visited Hanyang University Hospital for non-stress tests (NSTs). In these patients, FHR tracings were recorded for 50 min including the first and second 20 min of NST and 10 min of vibroacoustic stimulation test. All patients had a reactive NST with CLRC in these antepartum FHR tests. The rate of nonreactive tests and test duration times of these linear and nonlinear criteria were calculated and compared. Results: The rate of nonreactive tests within a 20- and 40-min period with the MNRC (6.8 and 1.2%) was significantly lower than with the CLRC (35.2 and 10.5%, respectively; p < 0.001). To meet the reactive criteria, the mean durations of the MNRC and the CLRC were 11.47 (95% CI, 11.11-11.84) and 18.45 (95% CI, 17.79-19.12) min, respectively (p < 0.001). The MNRC led to a significant reduction in testing time of 37.8% compared to the CLRC. The rate of reactive tests using only sample entropy (0.20), calculated over 5-min segments of FHR tracings, was 88.3% (95% CI, 88.0-88.7). It was close to the results using the MNRC (93.2%) in the 20-min time window. Conclusion: The use of the MNRC significantly reduced the test duration times and decreased the rate of nonreactive tests when compared to the CLRC. It may be useful in providing more rapid and accurate assessment of the fetus in electronic FHR monitoring. Copyright (C) 2010 S. Karger AG, Basel
引用
收藏
页码:92 / 99
页数:8
相关论文
共 30 条
[1]  
[Anonymous], 1997, AM J OBSTET GYNECOL, V177, P1385
[2]   PREDICTION OF FETAL DISTRESS AND POOR OUTCOME IN PROLONGED PREGNANCY USING DOPPLER ULTRASOUND AND FETAL HEART-RATE MONITORING COMBINED WITH STRESS TESTS .2. [J].
ARABIN, B ;
BECKER, R ;
MOHNHAUPT, A ;
VOLLERT, W ;
WEITZEL, HK .
FETAL DIAGNOSIS AND THERAPY, 1994, 9 (01) :1-6
[3]   Prediction of neonatal state by computer analysis of fetal heart rate tracings:: the anteparturn arm of the SisPorto® multicentre validation study [J].
Ayres-de-Campos, D ;
Costa-Santos, C ;
Bernardes, J .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2005, 118 (01) :52-60
[4]  
Bernardes J, 1999, ACTA OBSTET GYN SCAN, V78, P657
[5]   Linear and complex heart rate dynamics vary with sex in relation to fetal behavioural states [J].
Bernardes, Joao ;
Goncalves, Hernani ;
Ayres-De-Campos, Diogo ;
Rocha, Ana Paula .
EARLY HUMAN DEVELOPMENT, 2008, 84 (07) :433-439
[6]   The community of the self [J].
Buchman, TG .
NATURE, 2002, 420 (6912) :246-251
[7]   ANTENATAL CARDIOTOCOGRAM QUALITY AND INTERPRETATION USING COMPUTERS [J].
DAWES, GS ;
LOBB, M ;
MOULDEN, M ;
REDMAN, CWG ;
WHEELER, T .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (10) :791-797
[8]   CLINICAL-EXPERIENCE WITH THE HEWLETT-PACKARD M-1350A FETAL MONITOR - CORRELATION OF DOPPLER-DETECTED FETAL BODY MOVEMENTS WITH FETAL HEART-RATE PARAMETERS AND PERINATAL OUTCOME [J].
DEVOE, L ;
BOEHM, F ;
PAUL, R ;
FRIGOLETTO, F ;
PENSO, C ;
GOLDENBERG, R ;
RAYBURN, W ;
SMITH, C .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (02) :650-655
[9]   Linear and nonlinear heart-rate analysis in a rat model of acute anoxia [J].
Goncalves, Hernani ;
Henriques-Coelho, Tiago ;
Bernardes, Joao ;
Rocha, Ana Paula ;
Nogueira, Ana ;
Leite-Moreira, Adelino .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (09) :1133-1143
[10]   Linear and nonlinear analysis of heart rate patterns associated with fetal behavioral states in the antepartum period [J].
Goncalves, Hernani ;
Bernardes, Joao ;
Rocha, Ana Paula ;
Ayres-de-Campos, Diogo .
EARLY HUMAN DEVELOPMENT, 2007, 83 (09) :585-591