Dual chamber rate responsive pacing system driven by contractility:: Final assessment after 1-year follow-up

被引:20
作者
Clémenty, J [1 ]
机构
[1] Haut LEveque Hosp, F-33604 Bordeaux, France
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 11期
关键词
DDDR pacing; peak endocardial acceleration; cardiac contractility; long-term data;
D O I
10.1111/j.1540-8159.1998.tb01151.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to assess the long-term performance of a new dual chamber rate responsive pacing system based on the dynamic measurement of the peak endocardial acceleration (PEA) index of cardiac contractility Seventy patients who participated in the Multicenter European Clinical Evaluation were studied I year after implantation by continuously recording the PEA and the heart rate (HR) during exercise stress testing and during 24 hours of usual activities. A complete examination of standard parameters was also performed to assess the pacing/sensing lead characteristics. Statistical comparisons were performed with the data recorded with the same protocol at 1 month after implant for each patient. A linear correlation coefficient was calculated between PEA and sinus rate when the patient showed predominant atrial tracked rhythm. There were no significant differences between PEA values measured at 1 month and 1 year (PEA = 0.41 +/- 0.26 g vs 0.45 +/- 0.29 g at rest and PEA = 1.63 +/- 0.77 g vs 1.72 +/- 0.83 g during peak exercise). The correlation coefficient remained stable (0.67 +/- 0.15 vs 0.65 +/- 0.14 during daily life and 0.74 +/- 0.14 vs 0.77 +/- 0.11 during exercise). The PEA signal detected by the sensor was reliable and stable. No long-term complications or adverse effects were observed and the lead performance was comparable to that of a standard lead.
引用
收藏
页码:2192 / 2197
页数:6
相关论文
共 15 条
[1]  
BINNER L, 1998, PACE, V21, P894
[2]  
BOMBARDINI T, 1997, EUR HEART J, V18, P2354
[3]   Is local myocardial contractility related to endocardial acceleration signals detected by a transvenous pacing lead? [J].
Bongiorni, MG ;
Soldati, E ;
Arena, G ;
Quirino, G ;
Vernazza, F ;
Bernasconi, A ;
Garberoglio, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1682-1688
[4]  
CLEMENTY J, 1997, PACE, V20, P1591
[5]   A sensor-based evaluation of heart contractility in patients with head-up tilt-induced syncope [J].
Deharo, JC ;
Peyre, JP ;
Ritter, PH ;
Chalvidan, T ;
Berland, Y ;
Djiane, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01) :223-226
[6]  
DEHARO JC, 1997, EUR HEART J, V18, P1178
[7]  
GARBEROGLIO B, 1996, PROGR CLIN PACING, P165
[8]  
GILLIGAN DM, 1998, RECENT ADV CARDIAC P, V4, P3
[9]  
Luttikhuis HAO, 1997, PACEMAKER LEADS 1997, P253
[10]  
MENOZZI C, 1996, THERAPIES CARDIAC AR, P383