Influence of vent air valve opening on combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler

被引:63
作者
Li, Zhengqi [1 ]
Ren, Feng [1 ]
Zhang, Jie [1 ]
Zhang, Xiaohui [1 ]
Chen, Zhichao [1 ]
Chen, Lizhe [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Heilongjiang, Peoples R China
关键词
down-fired boiler; cyclone; NOx;
D O I
10.1016/j.fuel.2007.01.035
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Industrial experiments have been performed on a down-fired pulverized-coal 300 MWe utility boiler with vent air valve opening of 100% and 40%. The gas temperature distribution along the primary air and coal mixture flow, gas temperature distribution in the furnace, and gas components such as O-2, CO, CO2 and NOx in the near-wall region were measured for the first time. The influence of vent air valve opening on coal combustion in the furnace was determined. The results indicate that ignition of the primary air and pulverized-coal mixture is delayed. The position of the gas temperature peak is above the arches. Emission of NOx is up to 2101 mg/m(3) (at 6% 02 dry) with vent valve opening of 40%. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2457 / 2462
页数:6
相关论文
共 19 条
[1]   Particle characteristics in the radiant section of a coal-fired utility boiler [J].
Black, DL ;
McQuay, MQ .
COMBUSTION SCIENCE AND TECHNOLOGY, 1998, 132 (1-6) :37-74
[2]  
BLAS JG, 1970, COMBUSTION, V42, P6
[3]   LOCAL PARTICLE-VELOCITY, SIZE, AND CONCENTRATION MEASUREMENTS IN AN INDUSTRIAL-SCALE PULVERIZED COAL-FIRED BOILER [J].
BONIN, MP ;
QUEIROZ, M .
COMBUSTION AND FLAME, 1991, 85 (1-2) :121-133
[4]   A parametric evaluation of particle-phase dynamics in an industrial pulverized-coal-fired boiler [J].
Bonin, MP ;
Queiroz, M .
FUEL, 1996, 75 (02) :195-206
[5]  
BURDETT NA, 1987, J I ENERGY, V60, P103
[6]   LOCAL TEMPERATURE AND WALL RADIANT-HEAT FLUX MEASUREMENTS IN AN INDUSTRIAL-SCALE COAL FIRED BOILER [J].
BUTLER, BW ;
WEBB, BW .
FUEL, 1991, 70 (12) :1457-1464
[7]  
BUTLER BW, 1999, P COMBUST INST, V24, P1333
[8]   Measurements of gas species, temperature, and char burnout in a low-NOx pulverized-coal-fired utility boiler [J].
Costa, M ;
Silva, P ;
Azevedo, JLT .
COMBUSTION SCIENCE AND TECHNOLOGY, 2003, 175 (02) :271-289
[9]   Combustion characteristics of a front-wall-fired pulverized-coal 300 MWe utility boiler [J].
Costa, M ;
Azevedo, JLT ;
Carvalho, MG .
COMBUSTION SCIENCE AND TECHNOLOGY, 1997, 129 (1-6) :277-293
[10]   Modeling of coal combustion and NOx formation in a W-shaped boiler furnace [J].
Fan, JR ;
Jin, J ;
Liang, XH ;
Chen, LH ;
Cen, KF .
CHEMICAL ENGINEERING JOURNAL, 1998, 71 (03) :233-242