Low-dose and sparse sampling MDCT-based femoral bone strength prediction using finite element analysis

被引:13
作者
Rayudu, Nithin Manohar [1 ]
Anitha, D. Praveen [1 ]
Mei, Kai [2 ]
Zoffl, Florian [3 ]
Kopp, Felix K. [2 ]
Sollmann, Nico [3 ]
Loeffler, Maximilian T. [3 ]
Kirschke, Jan S. [3 ]
Noel, Peter B. [4 ]
Subburaj, Karupppasamy [1 ]
Baum, Thomas [3 ]
机构
[1] SUTD, Engn Prod Dev EPD Pillar, 8 Somapah Rd, Singapore 487372, Singapore
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Diagnost & Intervent Radiol, Ismaninger Str 22, D-81675 Munich, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Diagnost & Intervent Neuroradiol, Ismaninger Str 22, D-81675 Munich, Germany
[4] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Finite element analysis; Proximal femur; Multi-detector computed tomography; Statistical iterative reconstruction; Bone strength; Sparse sampling; Osteoporosis; MECHANICAL-PROPERTIES; ELDERLY-MEN; CT; FRACTURE; DENSITY; OSTEOPOROSIS; PRECISION; SPINE; WOMEN;
D O I
10.1007/s11657-020-0708-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aims to evaluate the impact of dose reduction through tube current and sparse sampling on multi-detector computed tomography (MDCT)-based femoral bone strength prediction using finite element (FE) analysis. FE-predicted femoral failure load obtained from MDCT scan data was not significantly affected by 50% dose reductions through sparse sampling. Further decrease in dose through sparse sampling (25% of original projections) and virtually reduced tube current (50% and 25% of the original dose) showed significant effects on the FE-predicted failure load results. Purpose To investigate the effect of virtually reduced tube current and sparse sampling on multi-detector computed tomography (MDCT)-based femoral bone strength prediction using finite element (FE) analysis. Methods Routine MDCT data covering the proximal femur of 21 subjects (17 males; 4 females; mean age, 71.0 +/- 8.8 years) without any bone diseases aside from osteoporosis were included in this study. Fifty percent and 75% dose reductions were achieved by virtually reducing tube current and by applying a sparse sampling strategy from the raw image data. Images were then reconstructed with a statistically iterative reconstruction algorithm. FE analysis was performed on all reconstructed images and the failure load was calculated. The root mean square coefficient of variation (RMSCV) and coefficient of correlation (R-2) were calculated to determine the variation in the FE-predicted failure load data for dose reductions, using original-dose MDCT scan as the standard of reference. Results Fifty percent dose reduction through sparse sampling showed lower RMSCV and higher correlations when compared with virtually reduced tube current method (RMSCV = 5.70%, R-2 = 0.96 vs. RMSCV = 20.78%, R-2 = 0.79). Seventy-five percent dose reduction achieved through both methods (RMSCV = 22.38%, R-2 = 0.80 for sparse sampling; RMSCV = 24.58%, R-2 = 0.73 for reduced tube current) could not predict the failure load accurately. Conclusion Our simulations indicate that up to 50% reduction in radiation dose through sparse sampling can be used for FE-based prediction of femoral failure load. Sparse-sampled MDCT may allow fracture risk prediction and treatment monitoring in osteoporosis with less radiation exposure in the future.
引用
收藏
页数:9
相关论文
共 45 条
[1]   Effects of sparse sampling schemes on image quality in low-dose CT [J].
Abbas, Sajid ;
Lee, Taewon ;
Shin, Sukyoung ;
Lee, Rena ;
Cho, Seungryong .
MEDICAL PHYSICS, 2013, 40 (11)
[2]   Effect of Statistically Iterative Image Reconstruction on Vertebral Bone Strength Prediction Using Bone Mineral Density and Finite Element Modeling: A Preliminary Study [J].
Anitha, D. ;
Subburaj, Karupppasamy ;
Kopp, Felix K. ;
Mei, Kai ;
Foehr, Peter ;
Burgkart, Rainer ;
Sollmann, Nico ;
Maegerlein, Christian ;
Kirschke, Jan S. ;
Noel, Peter B. ;
Baum, Thomas .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (01) :61-65
[3]   MDCT-based Finite Element Analysis of Vertebral Fracture Risk: What Dose is Needed? [J].
Anitha, D. ;
Mei, Kai ;
Dieckmeyer, Michael ;
Kopp, Felix K. ;
Sollmann, Nico ;
Zimmer, Claus ;
Kirschke, Jan S. ;
Noel, Peter B. ;
Baum, Thomas ;
Subburaj, Karupppasamy .
CLINICAL NEURORADIOLOGY, 2019, 29 (04) :645-651
[4]   Risk of vertebral compression fractures in multiple myeloma patients A finite-element study [J].
Anitha, D. ;
Thomas, Baum ;
Jan, Kirschke S. ;
Subburaj, Karupppasamy .
MEDICINE, 2017, 96 (02)
[5]   Effects of dose reduction on bone strength prediction using finite element analysis [J].
Anitha, D. ;
Subburaj, Karupppasamy ;
Mei, Kai ;
Kopp, Felix K. ;
Foehr, Peter ;
Noel, Peter B. ;
Kirschke, Jan S. ;
Baum, Thomas .
SCIENTIFIC REPORTS, 2016, 6
[6]   Implications of local osteoporosis on the efficacy of anti-resorptive drug treatment: a 3-year follow-up finite element study in risedronate-treated women [J].
Anitha, D. ;
Kim, K. J. ;
Lim, S. -K. ;
Lee, T. .
OSTEOPOROSIS INTERNATIONAL, 2013, 24 (12) :3043-3051
[7]   Volumetric quantitative CT of the spine and hip derived from contrast-enhanced MDCT:: Conversion factors [J].
Bauer, Jan S. ;
Henning, Tobias D. ;
Mueeller, Dirk ;
Lu, Ying ;
Majumdar, Sharmila ;
Link, Thomas M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) :1294-1301
[8]   Iterative reconstruction methods in X-ray CT [J].
Beister, Marcel ;
Kolditz, Daniel ;
Kalender, Willi A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02) :94-108
[9]   An Update on Dual-Energy X-Ray Absorptiometry [J].
Blake, Glen M. ;
Fogelman, Ignac .
SEMINARS IN NUCLEAR MEDICINE, 2010, 40 (01) :62-73
[10]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204