Spectrofluorimetry in organized media coupled to second-order multivariate calibration for the determination of galantamine in the presence of uncalibrated interferences

被引:26
作者
Culzoni, Maria J.
Aucelio, Ricardo Q. [2 ]
Escandar, Graciela M. [1 ]
机构
[1] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Dept Quim Analit, Inst Quim Rosario,CONICET, RA-2000 Rosario, Santa Fe, Argentina
[2] Pontificia Univ Catolica Rio de Janeiro, Dept Chem, BR-22453900 Rio De Janeiro, Brazil
关键词
Spectrofluorimetry; Organized media; Multivariate calibration; Galantamine; PARTIAL LEAST-SQUARES; ALZHEIMERS-DISEASE; RESIDUAL BILINEARIZATION; LIQUID-CHROMATOGRAPHY; HUMAN-PLASMA; GC-MS; GALANTHAMINE; CYCLODEXTRIN; ELECTROPHORESIS; FLUORESCENCE;
D O I
10.1016/j.talanta.2010.04.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present article describes the spectrofluorimetric determination of galantamine, a widely used acetylcholinesterase inhibitor, through excitation-emission fluorescence matrices and second-order calibration. With the purpose of enhancing the fluorescence intensity of this substance, the effect of different organized assemblies was evaluated. Although the interaction of galantamine with different cyclodextrins is weak, it was corroborated that the fluorescence intensity of this pharmaceutical in the presence of alpha-cyclodextrin is increased by a twofold factor. Among the studied micellar media, the anionic surfactant sodium dodecyl sulfate produced the largest signals for the compound of interest (sixfold enhancement), and was selected as auxiliary reagent for the subsequent determinations. The developed approach enabled the determination of galantamine at the ng mL(-1) level without the necessity of applying separation steps, and in the presence of uncalibrated interferences. The applied second-order chemometric tools were parallel factor analysis (PARAFAC), unfolded partial least-squares coupled to residual bilinearization (U-PLS/RBL), and multidimensional partial least-squares coupled to residual bilinearization (N-PLS/RBL). The ability of U-PLS/RBL to successfully overcome spectral interference problems is demonstrated. The quality of the proposed method was established with the determination of galantamine in both artificial and natural water samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:325 / 332
页数:8
相关论文
共 49 条
[1]   Carbamazepine in water: persistence in the environment, ozonation treatment and preliminary assessment on algal toxicity [J].
Andreozzi, R ;
Marotta, R ;
Pinto, G ;
Pollio, A .
WATER RESEARCH, 2002, 36 (11) :2869-2877
[2]  
[Anonymous], 2002, ANAL CHIM ACTA
[3]   Ibuprofen treatment modifies cortical sources of EEG rhythms in mild Alzheimer's disease [J].
Babiloni, Claudio ;
Frisoni, Giovanni B. ;
Del Percio, Claudio ;
Zanetti, Orazio ;
Bonomini, Cristina ;
Cassetta, Emanuele ;
Pasqualetti, Patrizio ;
Miniussi, Carlo ;
De Rosas, Mario ;
Valenzano, Anna ;
Cibelli, Giuseppe ;
Eusebi, Fabrizio ;
Rossini, Paolo M. .
CLINICAL NEUROPHYSIOLOGY, 2009, 120 (04) :709-718
[4]   Second-order advantage achieved by unfolded-partial least-squares/residual bilinearization modeling of excitation-emission fluorescence data presenting inner filter effects [J].
Bohoyo Gil, Diego ;
Munoz de la Pena, Arsenio ;
Arancibia, Juan A. ;
Escandar, Graciela M. ;
Olivieri, Alejandro C. .
ANALYTICAL CHEMISTRY, 2006, 78 (23) :8051-8058
[5]   When unfolding is better: unique success of unfolded partial least-squares regression with residual bilinearization for the processing of spectral-pH data with strong spectral overlapping. Analysis of fluoroquinolones in human urine based on flow-injection pH-modulated synchronous fluorescence data matrices [J].
Borraccetti, Mariano D. ;
Damiani, Patricia C. ;
Olivieri, Alejandro C. .
ANALYST, 2009, 134 (08) :1682-1691
[6]   Chemometrics-Assisted Excitation-Emission Fluorescence Spectroscopy on Nylon Membranes. Simultaneous Determination of Benzo[a]pyrene and Dibenz[a,h]anthracene at Parts-Per-Trillion Levels in the Presence of the Remaining EPA PAH Priority Pollutants As Interferences [J].
Bortolato, Santiago A. ;
Arancibia, Juan A. ;
Escandar, Graciela M. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8276-8286
[7]   Non-Trilinear Chromatographic Time Retention-Fluorescence Emission Data Coupled to Chemometric Algorithms for the Simultaneous Determination of 10 Polycyclic Aromatic Hydrocarbons in the Presence of Interferences [J].
Bortolato, Santiago A. ;
Arancibia, Juan A. ;
Escandar, Graciela M. .
ANALYTICAL CHEMISTRY, 2009, 81 (19) :8074-8084
[8]   A new efficient method for determining the number of components in PARAFAC models [J].
Bro, R ;
Kiers, HAL .
JOURNAL OF CHEMOMETRICS, 2003, 17 (05) :274-286
[9]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[10]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.0.CO