Label-free, ITO-based immunosensor for the detection of a cancer biomarker: Receptor for Activated C Kinase 1

被引:24
作者
Bahadir, E. B. [1 ]
Sezginturk, M. K. [2 ]
机构
[1] Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Namik Kemal Univ, Fac Sci, Dept Chem, Div Biochem, Tekirdag, Turkey
关键词
INDIUM-TIN OXIDE; SELF-ASSEMBLED MONOLAYER; GOLD NANOPARTICLES; GLUCOSE-OXIDASE; ELECTRODE; RACK1; IMMOBILIZATION; DEPOSITION; PREDICTOR; COMPOSITE;
D O I
10.1039/c6an00694a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, quite sensitive disposable immunosensor, based on the anti-RACK1 antibody, was developed for the determination of Receptor for Activated C Kinase 1 (RACK1) for the first time. Moreover, indium tin oxide (ITO) flexible sheets were modified by using aldehyde ended silane 11-(triethoxysilyl) undecanal (TESU) self-assembled monolayers (SAMs) for immobilizing the anti-RACK1 antibody via covalent bonds. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square wave voltammetry (SWV) methods were used for characterizing the immobilization steps and for determining the RACK1 concentration. To obtain a successful immunosensor, experimental factors were optimized. This quite sensitive biosensor was able to detect concentrations as low as fg mL(-1). The detection principle was based on the change in charge transfer resistance and the Nyquist plot diameter and these changes were monitored by using electrochemical impedance spectroscopy (EIS). This impedimetric immunosensor had perfect repeatability and reproducibility. We proved that the new silane agent, TESU, performs well in biosensor applications. The feasibility of the fabricated immunosensor was tested by detecting RACK1 in artificial and real human serum samples.
引用
收藏
页码:5618 / 5626
页数:9
相关论文
共 29 条
  • [1] RACK1, A multifaceted scaffolding protein: Structure and function
    Adams, David R.
    Ron, Dorit
    Kiely, Patrick A.
    [J]. CELL COMMUNICATION AND SIGNALING, 2011, 9
  • [2] Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer
    Arya, Sunil K.
    Prusty, Arun K.
    Singh, S. P.
    Solanki, Pratima R.
    Pandey, Manoj K.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. ANALYTICAL BIOCHEMISTRY, 2007, 363 (02) : 210 - 218
  • [3] Label-free ITO-based immunosensor for the detection of very low concentrations of pathogenic bacteria
    Barreiros dos Santos, M.
    Azevedo, S.
    Agusil, J. P.
    Prieto-Simon, B.
    Sporer, C.
    Torrents, E.
    Juarez, A.
    Teixeira, V.
    Samitier, J.
    [J]. BIOELECTROCHEMISTRY, 2015, 101 : 146 - 152
  • [4] Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection
    Canbaz, Mehmet Cetin
    Sezginturk, Mustafa Kemal
    [J]. ANALYTICAL BIOCHEMISTRY, 2014, 446 : 9 - 18
  • [5] RACK1 promotes breast carcinoma proliferation and invasion/metastasis in vitro and in vivo
    Cao, Xi-Xi
    Xu, Jing-Da
    Xu, Jia-Wen
    Liu, Xiao-Li
    Cheng, Yuan-Yuan
    Wang, Wen-Juan
    Li, Qing-Quan
    Chen, Qi
    Xu, Zu-De
    Liu, Xiu-Ping
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2010, 123 (02) : 375 - 386
  • [6] RACK1: a superior independent predictor for poor clinical outcome in breast cancer
    Cao, Xi-Xi
    Xu, Jing-Da
    Liu, Xiao-Li
    Xu, Jia-Wen
    Wang, Wen-Juan
    Li, Qing-Quan
    Chen, Qi
    Xu, Zu-De
    Liu, Xiu-Ping
    [J]. INTERNATIONAL JOURNAL OF CANCER, 2010, 127 (05) : 1172 - 1179
  • [7] Electrochemically reduced graphene-gold nano particle composite on indium tin oxide for label free immuno sensing of estradiol
    Dharuman, Venkataraman
    Hahn, Jong Hoon
    Jayakumar, Kumarasamy
    Teng, Wei
    [J]. ELECTROCHIMICA ACTA, 2013, 114 : 590 - 597
  • [8] Development of a stable cholesterol biosensor based on multi-walled carbon nanotubes-gold nanoparticles composite covered with a layer of chitosan-room-temperature ionic liquid network
    Gopalan, Anantha Iyengar
    Lee, Kwang-Pill
    Ragupathy, Dhanusuraman
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) : 2211 - 2217
  • [9] Selective functionalisation of PDMS-based photonic lab on a chip for biosensing
    Ibarlucea, Bergoi
    Fernandez-Sanchez, Cesar
    Demming, Stefanie
    Buettgenbach, Stephanus
    Llobera, Andreu
    [J]. ANALYST, 2011, 136 (17) : 3496 - 3502
  • [10] AuNPs modified, disposable, ITO based biosensor: Early diagnosis of heat shock protein 70
    Karaboga, Munteha Nur Sonuc
    Simsek, Cigdem Sayikli
    Sezginturk, Mustafa Kemal
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 84 : 22 - 29