PDMS-based micro PCR chip with parylene coating

被引:289
作者
Shin, YS [1 ]
Cho, K
Lim, SH
Chung, S
Park, SJ
Chung, C
Han, DC
Chang, JK
机构
[1] Seoul Natl Univ, Sch Mech & Aerosp Engn, Seoul 151742, South Korea
[2] Seoul Natl Univ, Sch Elect Engn & Comp Sci, Seoul 151742, South Korea
[3] Digital Bio Technol Co, Seoul 151742, South Korea
关键词
D O I
10.1088/0960-1317/13/5/332
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a microchip for polymerase chain reaction (PCR) with polydimethylsiloxane (PDMS). PDMS has good characteristics: it is cheap, transparent, easy to fabricate and biocompatible. But in micro PCR, the porosity of PDMS causes several critical problems such as bubble formation, sample evaporation and protein adsorption. To solve those problems, we coated the micro PCR chips with Parylene film, which has low permeability to moisture and long-term stability. We investigated the influence of low thermal conductivity of PDMS and Parylene on the thermal characteristics of the PCR chips with numerical analysis. The thermal responses of micro PCR chips were compared for three materials: silicon, glass and PDMS. From the results, we identified appropriate thermal responses of the PDMS-based micro PCR chips by heating both the top and bottom sides. We could successfully amplify the angiotensin converting enzyme gene with as small a volume as 2 mul on the PDMS-based micro PCR chips without any additives.
引用
收藏
页码:768 / 774
页数:7
相关论文
共 21 条
[1]  
Beebe D J, 2001, MEC IND, V2, P343
[2]   A miniaturized cyclic PCR device - modeling and experiments [J].
Chou, CF ;
Changrani, R ;
Roberts, P ;
Sadler, D ;
Burdon, J ;
Zenhausern, F ;
Lin, S ;
Mulholland, A ;
Swami, N ;
Terbrueggen, R .
MICROELECTRONIC ENGINEERING, 2002, 61-2 :921-925
[3]   Chip-MS: Coupling the large with the small [J].
de Mello, AJ .
LAB ON A CHIP, 2001, 1 (01) :7N-12N
[4]   Polymerase chain reaction in polymeric microchips:: DNA amplification in less than 240 seconds [J].
Giordano, BC ;
Ferrance, J ;
Swedberg, S ;
Hühmer, AFR ;
Landers, JP .
ANALYTICAL BIOCHEMISTRY, 2001, 291 (01) :124-132
[5]  
Giordano BC, 2001, ELECTROPHORESIS, V22, P334, DOI 10.1002/1522-2683(200101)22:2<334::AID-ELPS334>3.0.CO
[6]  
2-O
[7]   Hydrophobicity recovery of polydimethylsiloxane after exposure to corona discharges [J].
Hillborg, H ;
Gedde, UW .
POLYMER, 1998, 39 (10) :1991-1998
[8]  
Hong JW, 2001, ELECTROPHORESIS, V22, P328
[9]   Determination of human angiotensin converting enzyme (ACE) gene polymorphisms in erectile dysfunction: Frequency differences of ACE gene polymorphisms according to the method of analysis [J].
Kim, DS ;
Choi, SI ;
Lee, HS ;
Park, JK ;
Yi, HK .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (01) :11-14
[10]   Chemical amplification: Continuous-flow PCR on a chip [J].
Kopp, MU ;
de Mello, AJ ;
Manz, A .
SCIENCE, 1998, 280 (5366) :1046-1048