Electrochemical Determination of Chlorogenic Acid in Nutraceuticals Using Voltammetric Sensors Based on Screen-Printed Carbon Electrode Modified with Graphene and Gold Nanoparticles

被引:35
作者
Munteanu, Irina-Georgiana [1 ]
Apetrei, Constantin [1 ]
机构
[1] Dunarea de Jos Univ Galati, Dept Chem Phys & Environm, Fac Sci & Environm, Galati 800008, Romania
关键词
chlorogenic acid; cyclic voltammetry; graphene; gold nanoparticles; sensor; MICROWAVE-ASSISTED EXTRACTION; IONIC LIQUID; QUANTIFICATION; TECHNOLOGY; BIOSENSORS; BEHAVIOR; OXIDE;
D O I
10.3390/ijms22168897
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The present study describes the electrochemical properties of three screen-printed electrodes (SPEs), the first electrode being carbon-based (C), the second graphene-based (GPH), and the third based on GPH modified with gold nanoparticles (GNP). These electrodes were used for the study of the electrochemical behavior of chlorogenic acid in different aqueous solutions, at pH = 7. In chlorogenic acid solution, a redox process was noticed in the case of all three electrodes; GPH and GNP significantly improved the sensor response regarding sensitivity and reversibility, a fact demonstrated by characterizing the sensor by cyclic voltammetry in potassium ferrocyanide, which corresponds to the exchange of two electrons and two protons. Moreover, the calibration curves for each sensor were developed, subsequently calculating the detection limits (LOD) and the quantification limits (LOQ). Low LOD and LOQ were obtained, the best-of the order of 10(-7) M (LOD = 0.62 x 10(-7) M; LOQ = 1.97 x 10(-7) M)-being obtained in the case of GPH-GNP-SPE, which demonstrates that the method may be applied for determining chlorogenic acid in real samples. Thus, the sensors were successfully used for the quantitative determination of chlorogenic acid in three nutraceutical products. The validation of the results was done using the FTIR method. The results obtained by cyclic voltammetry were in accordance with those obtained by the spectrometric method, without significant differences from a statistical point of view.
引用
收藏
页数:16
相关论文
共 52 条
[1]   Nano-crystalline graphite film on SiO2: Electrochemistry and electro-analytical application [J].
Albu, Camelia ;
Eremia, Sandra A. V. ;
Veca, Monica Lucia ;
Avram, Andrei ;
Popa, Radu Cristian ;
Pachiu, Cristina ;
Romanitan, Cosmin ;
Kusko, Mihaela ;
Gavrila, Raluca ;
Radoi, Antonio .
ELECTROCHIMICA ACTA, 2019, 303 :284-292
[2]   Recent developments in nanotechnology-based printing electrode systems for electrochemical sensors [J].
Ambaye, Abera Demeke ;
Kefeni, Kebede Keterew ;
Mishra, Shivani Bhardwaj ;
Nxumalo, Edward Ndumiso ;
Ntsendwana, Bulelwa .
TALANTA, 2021, 225
[3]  
[Anonymous], 2010, EUROPEAN PHARMACOPOE
[4]   A modified nanostructured graphene-gold nanoparticle carbon screen-printed electrode for the sensitive voltammetric detection of rutin [J].
Apetrei, I. M. ;
Apetrei, C. .
MEASUREMENT, 2018, 114 :37-43
[5]   Development of a Novel Biosensor Based on Tyrosinase/Platinum Nanoparticles/Chitosan/Graphene Nanostructured Layer with Applicability in Bioanalysis [J].
Apetrei, Irina Mirela ;
Apetrei, Constantin .
MATERIALS, 2019, 12 (07)
[6]   Voltammetric determination of melatonin using a graphene-based sensor in pharmaceutical products [J].
Apetrei, Irina Mirela ;
Apetrei, Constantin .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2016, 11 :1859-1866
[7]  
Armbruster David A, 2008, Clin Biochem Rev, V29 Suppl 1, pS49
[8]  
Bard A. J., 2001, ELECTROCHEMICAL METH
[9]   Carbonaceous Nanomaterials Employed in the Development of Electrochemical Sensors Based on Screen-Printing Technique-A Review [J].
Bounegru, Alexandra Virginia ;
Apetrei, Constantin .
CATALYSTS, 2020, 10 (06)
[10]   Voltammetric determination of chlorogenic acid in pharmaceutical products using poly(aminosulfonic acid) modified glassy carbon electrode [J].
Chao, Mingyong ;
Ma, Xinying .
JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (04) :512-519