Contactless optical coherence tomography of the eyes of freestanding individuals with a robotic scanner

被引:29
|
作者
Draelos, Mark [1 ]
Ortiz, Pablo [1 ]
Qian, Ruobing [1 ]
Viehland, Christian [1 ]
McNabb, Ryan [2 ]
Hauser, Kris [3 ]
Kuo, Anthony N. [1 ,2 ]
Izatt, Joseph A. [1 ,2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Duke Univ, Med Ctr, Dept Ophthalmol, Durham, NC 27710 USA
[3] Duke Univ, Dept Elect & Comp Engn, Durham, NC USA
关键词
CENTRAL CORNEAL THICKNESS; OCULAR FUNDUS PHOTOGRAPHY; HAND-HELD; IN-VIVO; RETINAL THICKNESS; OCT; ARTIFACTS; SEGMENT; PROBE; AGE;
D O I
10.1038/s41551-021-00753-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A robot-mounted scanner enables optical coherence tomography, at safe distances, of the eyes of freestanding individuals without operator intervention or head stabilization. Clinical systems for optical coherence tomography (OCT) are used routinely to diagnose and monitor patients with a range of ocular diseases. They are large tabletop instruments operated by trained staff, and require mechanical stabilization of the head of the patient for positioning and motion reduction. Here we report the development and performance of a robot-mounted OCT scanner for the autonomous contactless imaging, at safe distances, of the eyes of freestanding individuals without the need for operator intervention or head stabilization. The scanner uses robotic positioning to align itself with the eye to be imaged, as well as optical active scanning to locate the pupil and to attenuate physiological eye motion. We show that the scanner enables the acquisition of OCT volumetric datasets, comparable in quality to those of clinical tabletop systems, that resolve key anatomic structures relevant for the management of common eye conditions. Robotic OCT scanners may enable the diagnosis and monitoring of patients with eye conditions in non-specialist clinics.
引用
收藏
页码:726 / 736
页数:11
相关论文
共 50 条
  • [1] Active Motion Cancellation for Robotic Optical Coherence Tomography of Moving Eyes: A Nystagmus Phantom Study
    Pan, Haochi
    Lim, Chae Woo
    King, Katelyn
    Guan, Renxiang
    Draelos, Mark
    2024 INTERNATIONAL SYMPOSIUM ON MEDICAL ROBOTICS, ISMR 2024, 2024,
  • [2] Automatic Optical Coherence Tomography Imaging of Stationary and Moving Eyes with a Robotically-Aligned Scanner
    Draelos, Mark
    Ortiz, Pablo
    Qian, Ruobing
    Keller, Brenton
    Hauser, Kris
    Kuo, Anthony
    Izatt, Joseph
    2019 INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2019, : 8897 - 8903
  • [3] Distal planar rotary scanner for endoscopic optical coherence tomography
    Searles, Kyle
    Shalabi, Nabil
    Hohert, Geoffrey
    Gharib, Nirvana
    Jayhooni, Sayed Mohammad Hashem
    Lane, Pierre M.
    Takahata, Kenichi
    BIOMEDICAL ENGINEERING LETTERS, 2024, 14 (03) : 583 - 592
  • [4] FULL FINGERPRINT SCANNER USING OPTICAL COHERENCE TOMOGRAPHY
    Breithaupt, Ralph
    Sousedik, Ctirad
    Meissner, Sven
    2015 INTERNATIONAL WORKSHOP ON BIOMETRICS AND FORENSICS (IWBF), 2015,
  • [5] Optical coherence tomography findings for nanophthalmic eyes
    Bijlsma, Ward R.
    van Schooneveld, Mary J.
    van der Lelij, Allegonda
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (07): : 1002 - 1007
  • [6] Optical coherence tomography and neurodegeneration: are eyes the windows to the brain?
    Gupta, Sahil
    Zivadinov, Robert
    Ramanathan, Murali
    Weinstock-Guttman, Bianca
    EXPERT REVIEW OF NEUROTHERAPEUTICS, 2016, 16 (07) : 765 - 775
  • [7] En-face optical coherence tomography/fluorescence endomicroscopy for minimally invasive imaging using a robotic scanner
    Marques, Manuel J.
    Hughes, Michael R.
    Vyas, Khushi
    Thrapp, Andrew
    Zhang, Haojie
    Bradu, Adrian
    Gelikonov, Grigory
    Giataganas, Petros
    Payne, Christopher J.
    Yang, Guang-Zhong
    Podoleanu, Adrian
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (06)
  • [8] Macular thickness and volume of myopic eyes measured using spectral-domain optical coherence tomography
    Hwang, Young Hoon
    Kim, Yong Yeon
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (05) : 492 - 498
  • [9] OPTICAL COHERENCE TOMOGRAPHY CHARACTERISTICS IN EYES WITH OPTIC PIT MACULOPATHY
    Roy, Rupak
    Waanbah, Anton D.
    Mathur, Gaurav
    Raman, Rajiv
    Sharma, Tarun
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (04): : 771 - 775
  • [10] MEMS scanner based swept source laser for optical coherence tomography
    Totsuka, Kouki
    Isamoto, Keiji
    Sakai, Tooru
    Morosawa, Atsushi
    Chong, Changho
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554