SENSORY FEEDBACK FROM A PROSTHETIC HAND BASED ON AIR-MEDIATED PRESSURE FROM THE HAND TO THE FOREARM SKIN

被引:85
作者
Antfolk, Christian [2 ]
Bjorkman, Anders [1 ]
Frank, Sven-Olof [3 ]
Sebelius, Fredrik [2 ]
Lundborg, Goran [1 ]
Rosen, Birgitta [1 ]
机构
[1] Skane Univ Hosp, Dept Hand Surg, SE-20502 Malmo, Sweden
[2] Lund Univ, Dept Measurement Technol & Ind Elect Engn, Lund, Sweden
[3] Scandinavian Orthopaed Lab, Lund, Sweden
基金
瑞典研究理事会;
关键词
sensory feedback; prosthesis; forearm amputees; UPPER-LIMB PROSTHESES; CLOSED-LOOP CONTROL; TACTILE DISPLAY; SUBSTITUTION; AMPUTEES; DESIGN; PERCEPTION; SENSATIONS; CORTEX; SYSTEM;
D O I
10.2340/16501977-1001
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: Lack of sensory feedback is a drawback in today's hand prostheses. We present here a non-invasive simple sensory feedback system, which provides the user of a prosthetic hand with sensory feedback on the arm stump. It is mediated by air in a closed loop system connecting silicone pads on the prosthetic hand with pads on the amputation stump. The silicone pads in a "tactile display" on the amputation stump expand when their corresponding sensor-bulb in the prosthesis is touched, evoking an experience of "real touch". Methods: Twelve trans-radial amputees and 20 healthy non-amputees participated in the study. We investigated the capacity of the system to mediate detection of touch, discrimination between different levels of pressure and, on the amputees also, the ability to locate touch. Results: The results showed a median touch threshold of 80 and 60 g in amputees and non-amputees, respectively, and 90% and 80% correct answers, respectively, in discrimination between 2 levels of pressure. The amputees located touch (3 sites) correctly in 96% of trials. Conclusion This simple sensory feedback system has the potential to restore sensory feedback in hand amputees and thus it could be a useful tool to enhance prosthesis use.
引用
收藏
页码:702 / 707
页数:6
相关论文
共 36 条
[1]  
AITKEN S, 1983, INT J NEUROSCI, V19, P13, DOI 10.3109/00207458309148641
[2]  
[Anonymous], MYOHAND VARIPLUS SPE
[3]   Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system [J].
Antfolk, Christian ;
Balkenius, Christian ;
Lundborg, Goran ;
Rosen, Birgitta ;
Sebelius, Fredrik .
BIOMEDICAL ENGINEERING ONLINE, 2010, 9
[4]   SmartHand tactile display: A new concept for providing sensory feedback in hand prostheses [J].
Antfolk, Christian ;
Balkenius, Christian ;
Rosen, Birgitta ;
Lundborg, Goran ;
Sebelius, Fredrik .
JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2010, 44 (01) :50-53
[5]  
*ASHT, 1992, CLIN ASS REC
[6]  
Atkins DJ., 1996, J PROSTHET ORTHOT, V8, P2, DOI DOI 10.1097/00008526-199601000-00003
[7]   ARTIFICIAL TOUCH IN A HAND-PROSTHESIS [J].
BEEKER, TW ;
DURING, J ;
DENHERTO.A .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (01) :47-&
[8]   Consumer design priorities for upper limb prosthetics [J].
Biddiss, Elaine ;
Beaton, Dorcas ;
Chau, Tom .
DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2007, 2 (06) :346-357
[9]  
Bjorkman A, 2009, 65 ANN M AM SOC SURG
[10]   A. sensorized thumb for force closed-loop control of hand neuroprostheses [J].
Carpaneto, J ;
Micera, S ;
Zaccone, F ;
Vecchi, F ;
Dario, P .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (04) :346-353