SENSORY FEEDBACK FROM A PROSTHETIC HAND BASED ON AIR-MEDIATED PRESSURE FROM THE HAND TO THE FOREARM SKIN

被引:82
|
作者
Antfolk, Christian [2 ]
Bjorkman, Anders [1 ]
Frank, Sven-Olof [3 ]
Sebelius, Fredrik [2 ]
Lundborg, Goran [1 ]
Rosen, Birgitta [1 ]
机构
[1] Skane Univ Hosp, Dept Hand Surg, SE-20502 Malmo, Sweden
[2] Lund Univ, Dept Measurement Technol & Ind Elect Engn, Lund, Sweden
[3] Scandinavian Orthopaed Lab, Lund, Sweden
基金
瑞典研究理事会;
关键词
sensory feedback; prosthesis; forearm amputees; UPPER-LIMB PROSTHESES; CLOSED-LOOP CONTROL; TACTILE DISPLAY; SUBSTITUTION; AMPUTEES; DESIGN; PERCEPTION; SENSATIONS; CORTEX; SYSTEM;
D O I
10.2340/16501977-1001
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: Lack of sensory feedback is a drawback in today's hand prostheses. We present here a non-invasive simple sensory feedback system, which provides the user of a prosthetic hand with sensory feedback on the arm stump. It is mediated by air in a closed loop system connecting silicone pads on the prosthetic hand with pads on the amputation stump. The silicone pads in a "tactile display" on the amputation stump expand when their corresponding sensor-bulb in the prosthesis is touched, evoking an experience of "real touch". Methods: Twelve trans-radial amputees and 20 healthy non-amputees participated in the study. We investigated the capacity of the system to mediate detection of touch, discrimination between different levels of pressure and, on the amputees also, the ability to locate touch. Results: The results showed a median touch threshold of 80 and 60 g in amputees and non-amputees, respectively, and 90% and 80% correct answers, respectively, in discrimination between 2 levels of pressure. The amputees located touch (3 sites) correctly in 96% of trials. Conclusion This simple sensory feedback system has the potential to restore sensory feedback in hand amputees and thus it could be a useful tool to enhance prosthesis use.
引用
收藏
页码:702 / 707
页数:6
相关论文
共 45 条
  • [1] Sensory Feedback in SEMG Prosthetic Hand
    Zhang, Leilei
    Sun, Ying
    He, Yang
    Tan, Chong
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON MANAGEMENT, EDUCATION, INFORMATION AND CONTROL (MEICI 2017), 2017, 156 : 796 - 800
  • [2] Evaluation of Sensory Feedback from a Robotic Hand: A Preliminary Study
    Karakus, Ipek
    Sahin, Hasan
    Atasoy, Ahmet
    Kaplanoglu, Erkan
    Ozkan, Mehmed
    Guclu, Burak
    HAPTICS: SCIENCE, TECHNOLOGY, AND APPLICATIONS, PT II, 2018, 10894 : 452 - 463
  • [3] Innovative Multi Vibrotactile-Skin Stretch (MuViSS) haptic device for sensory motor feedback from a robotic prosthetic hand
    Campanelli, Andrea
    Tiboni, Monica
    Verite, Fabien
    Saudrais, Charlelie
    Mick, Sebastien
    Jarrasse, Nathanael
    MECHATRONICS, 2024, 99
  • [4] Comparison of Remote Pressure and Vibrotactile Feedback for Prosthetic Hand Control
    Tejeiro, Camilo
    Stepp, Cara E.
    Malhotra, Mark
    Rombokas, Eric
    Matsuoka, Yoky
    2012 4TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2012, : 521 - 525
  • [5] Artificial Redirection of Sensation From Prosthetic Fingers to the Phantom Hand Map on Transradial Amputees: Vibrotactile Versus Mechanotactile Sensory Feedback
    Antfolk, Christian
    D'Alonzo, Marco
    Controzzi, Marco
    Lundborg, Goran
    Rosen, Birgitta
    Sebelius, Fredrik
    Cipriani, Christian
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2013, 21 (01) : 112 - 120
  • [6] A Sensory Feedback System for Prosthetic Hand Based on Evoked Tactile Sensation
    Liu, X. X.
    Chai, G. H.
    Qu, H. E.
    Lan, N.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 2493 - 2496
  • [7] Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study
    Gonzalez, Jose
    Soma, Hirokazu
    Sekine, Masashi
    Yu, Wenwei
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2012, 9
  • [8] Mechanotactile Sensory Feedback Improves Embodiment of a Prosthetic Hand During Active Use
    Shehata, Ahmed W.
    Rehani, Mayank
    Jassat, Zaheera E.
    Hebert, Jacqueline S.
    FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [9] Development of Sensory Feedback Device for Myoelectric Prosthetic Hand to Provide Hardness of Objects to Users
    Morita, Takakuni
    Kikuchi, Takeshi
    Ishii, Chiharu
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2016, 28 (03) : 361 - 370
  • [10] Phantom Finger Perception Evoked with Transcutaneous Electrical Stimulation for Sensory Feedback of Prosthetic Hand
    Chai, G. H.
    Li, S.
    Sui, X. H.
    Mei, Z.
    He, L. W.
    Zhong, C. L.
    Wang, J. W.
    Zhang, D. G.
    Zhu, X. Y.
    Lan, N.
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 271 - 274