Continuous Monitoring of Vital Signs in the General Ward Using Wearable Devices: Randomized Controlled Trial

被引:73
作者
Weenk, Mariska [1 ]
Bredie, Sebastian J. [1 ]
Koeneman, Mats [1 ]
Hesselink, Gijs [1 ]
van Goor, Harry [1 ]
van de Belt, Tom H. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, POB 9101, NL-6500 HB Nijmegen, Netherlands
关键词
remote sensing technology; wireless technology; continuous monitoring; vital signs; wearable electronic devices; remote monitoring; digital health; INTENSIVE-CARE-UNIT; UNPLANNED ADMISSION; PATIENT SAFETY; TECHNOLOGY; RISK; INFORMATION; ADOPTION; ALARMS; ICU;
D O I
10.2196/15471
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Wearable devices can be used for continuous patient monitoring in the general ward, increasing patient safety. Little is known about the experiences and expectations of patients and health care professionals regarding continuous monitoring with these devices. Objective: This study aimed to identify positive and negative effects as well as barriers and facilitators for the use of two wearable devices: ViSi Mobile (VM) and HealthPatch (HP). Methods: In this randomized controlled trial, 90 patients admitted to the internal medicine and surgical wards of a university hospital in the Netherlands were randomly assigned to continuous vital sign monitoring using VM or HP and a control group. Users' experiences and expectations were addressed using semistructured interviews. Nurses, physician assistants, and medical doctors were also interviewed. Interviews were analyzed using thematic content analysis. Psychological distress was assessed using the State Trait Anxiety Inventory and the Pain Catastrophizing Scale. The System Usability Scale was used to assess the usability of both devices. Results: A total of 60 patients, 20 nurses, 3 physician assistants, and 6 medical doctors were interviewed. We identified 47 positive and 30 negative effects and 19 facilitators and 36 barriers for the use of VM and HP. Frequently mentioned topics included earlier identification of clinical deterioration, increased feelings of safety, and VM lines and electrodes. No differences related to psychological distress and usability were found between randomization groups or devices. Conclusions: Both devices were well received by most patients and health care professionals, and the majority of them encouraged the idea of monitoring vital signs continuously in the general ward. This comprehensive overview of barriers and facilitators of using wireless devices may serve as a guide for future researchers, developers, and health care institutions that consider implementing continuous monitoring in the ward.
引用
收藏
页数:11
相关论文
共 51 条
[1]   Mobile health apps and recovery after surgery: What are patients willing to do? [J].
Abelson, Jonathan S. ;
Symer, Matthew ;
Peters, Alex ;
Charlson, Mary ;
Yeo, Heather .
AMERICAN JOURNAL OF SURGERY, 2017, 214 (04) :616-622
[2]  
[Anonymous], P 2014 IEEE HEALTHC
[3]  
[Anonymous], 1970, STAI MANUAL
[4]   Reducing false alarms in the ICU by quantifying self-similarity of multimodal biosignals [J].
Antink, Christoph Hoog ;
Leonhardt, Steffen ;
Walter, Marian .
PHYSIOLOGICAL MEASUREMENT, 2016, 37 (08) :1233-1252
[5]  
Appelboom G, 2014, ARCH PUBLIC HEALTH, V72, DOI 10.1186/2049-3258-72-28
[6]   Big Data In Health Care: Using Analytics To Identify And Manage High-Risk And High-Cost Patients [J].
Bates, David W. ;
Saria, Suchi ;
Ohno-Machado, Lucila ;
Shah, Anand ;
Escobar, Gabriel .
HEALTH AFFAIRS, 2014, 33 (07) :1123-1131
[7]   Reducing cardiac arrests in the acute admissions unit: a quality improvement journey [J].
Beckett, Daniel J. ;
Inglis, Monica ;
Oswald, Sharon ;
Thomson, Elaine ;
Harley, Wilma ;
Wilson, Jennifer ;
Lloyd, Robert C. ;
Rooney, Kevin D. .
BMJ QUALITY & SAFETY, 2013, 22 (12) :1025-1031
[8]  
Beckett Dj, 2009, Acute Med, V8, P33
[9]   Wireless Vital Sign Monitoring in Pregnant Women: A Functionality and Acceptability Study [J].
Boatin, Adeline Adwoa ;
Wylie, Blair Johnson ;
Goldfarb, Ilona ;
Azevedo, Robin ;
Pittel, Elena ;
Ng, Courtney ;
Haberer, Jessica Elizabeth .
TELEMEDICINE AND E-HEALTH, 2016, 22 (07) :564-571
[10]  
Braun V., 2006, Qualitative Research in Psychology, V3, P77, DOI [10.1191/1478088706qp063oa, DOI 10.1191/1478088706QP063OA, DOI 10.1080/10875549.2021.1929659]