Behavior of Y-type perfobond rib shear connection under different cyclic loading conditions

被引:11
|
作者
Kim, Kun-Soo [1 ]
Han, Oneil [2 ]
Heo, Won-Ho [1 ]
Kim, Sang-Hyo [2 ]
机构
[1] Korea Inst Civil Engn & Bldg Technol, 283 Goyang Dae Ro, Goyang Si 10223, Gyeonggi Do, South Korea
[2] Yonsei Univ, Sch Civil & Environm Engn, 50 Yonsei Ro, Seoul 03722, South Korea
关键词
Stubby Y-type perfobond rib shear connector; Cyclic load; Shear behavior; Plastic slip; HIGH-STRENGTH; HYSTERETIC PERFORMANCE; COMPOSITE DOWELS; SLIP BEHAVIOR; STUDS; CHANNEL; TESTS;
D O I
10.1016/j.istruc.2020.04.053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A cyclic loading test is a simple method to determine the behavior of shear connection between steel and concrete. Tests using different cases of cyclic loading is necessary since most experimental programs considered limited loading conditions during reversed cyclic loading test. Various cyclic loading cases should be applied during cyclic tests in order to consider different situations. This study applied various cyclic loading cases to analyze and verify the effect of cyclic behavior on shear connection using stubby Y-type perfobond rib shear connectors. Our result show that the shear strength under cyclic loads was lower than that under monotonic load. Furthermore, plastic slip occurred after cyclic loads in each test.
引用
收藏
页码:562 / 571
页数:10
相关论文
共 50 条
  • [1] Influence of transverse rebar on shear behavior of Y-type perfobond rib shear connection
    Kim, Sang-Hyo
    Kim, Kun-Soo
    Han, Oneil
    Park, Jun-Seung
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 180 : 254 - 264
  • [2] Behavior of composite girder with Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Choi, Jaegu
    Park, Se-Jun
    Ahn, Jin-Hee
    Jung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 103 : 275 - 289
  • [3] Y-type perfobond rib shear connectors subjected to fatigue loading on highway bridges
    Kim, Sang-Hyo
    Kim, Kun-Soo
    Park, Sejun
    Aim, Jin-Hee
    Lee, Min-Kyu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 : 445 - 454
  • [4] Group effect of Y-type perfobond rib shear connectors
    Altanzagas, O.
    Ganzorig, E.
    Kim, S. H.
    Han, O.
    Kim, T. S.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 401 - 407
  • [5] Shear Resistance Assessment of the Y-Type Perfobond Rib Shear Connector under Repeated Loadings
    Kim, Sang-Hyo
    Han, Oneil
    Yoon, Suro
    Boldoo, Tuguldur
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [6] Experimental behavior of double-row Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Han, Oneil
    Kim, Kun-Soo
    Park, Jun-Seung
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 150 : 221 - 229
  • [7] Generalized formulation for shear resistance on Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Park, Sejun
    Kim, Kun-Soo
    Jung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 128 : 245 - 260
  • [8] Experimental shear resistance evaluation of Y-type perfobond rib shear connector
    Kim, Sang-Hyo
    Choi, Kyu-Tae
    Park, Se-Jun
    Park, Seung-Min
    Lung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 82 : 1 - 18
  • [9] Shear Resistance of Perfobond Rib Shear Connectors under Cyclic Loading
    Zhao, Canhui
    Wang, Yuechen
    Zhu, Shengchun
    Deng, Kailai
    Li, Zhixiang
    Yuan, Xing
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (02)
  • [10] Energy dissipating characteristics of Y-type perfobond rib shear connectors
    Kim, S. H.
    Kim, K. S.
    Han, O.
    Choi, J. G.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 386 - 389