This study presents a model to analyse and simulate tidal power generation for hybrid power system in the presence of highly infiltrated tidal units. The response of the hybrid system may be at risk without suitable frequency enhancement techniques. The complete load frequency model is a combination of conventional automatic generation control (AGC) and automatic voltage regulator (AVR). AVR is employed to keep the output voltage magnitude of conventional generator at a particular level. The purpose of integrating AGC with AVR is to maintain the equilibrium between system's generation and load as well as to keep the frequency of system within suitable range. Owing to inclusion of nonconventional sources, the total inertia of the power system is eventually diminished. Conventional PID droop controller demonstrates inefficacy in diminishing the frequency deviations due to slow controlling action. This research proposes a fractional order (FO) fuzzy PID droop in de-loaded area to improvise the frequency excursion over fixed/Fuzzy PID/PID droop controllers. Imperialist competitive algorithm (ICA) is employed to tune the parameters of the controllers. ICA optimized fractional order PID droop control strategy unveils best performance (settling time = 11.65 s, undershoot amplitude = 0.26pu, performance index = 0.072e-6) over the integer order fuzzy PID control (settling time = 12.02 s, undershoot amplitude = 0.278 pu, performance index = 0.189e-6) and PID droop control (settling time = 30.68 s, undershoot amplitude = 0.95 pu, performance index = 0.215e-6). Examination of dynamic responses for abrupt changes in load request divulges the pre-eminence of proposed droop controller strategy with others controllers. The comprehensive study carried out in this paper implies that ICA optimized controller operates properly and has proven its robustness for +/- 10% variations in system parameters and physical constraints (Generation rate constraints, governor dead band, and time delay). This study also analyses the effect of tidal power plant contribution in the frequency regulation by inertia, primary and secondary frequency control. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] An improved moth swarm algorithm based fractional order type-2 fuzzy PID controller for frequency regulation of microgrid system
    Prusty, Umesh Chandra
    Nayak, Pratap Chandra
    Prusty, Ramesh Chandra
    Panda, Sidhartha
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022,
  • [32] A Robust Fractional-Order PID Controller Based Load Frequency Control Using Modified Hunger Games Search Optimizer
    Fathy, Ahmed
    Yousri, Dalia
    Rezk, Hegazy
    Thanikanti, Sudhakar Babu
    Hasanien, Hany M.
    ENERGIES, 2022, 15 (01)
  • [33] Management of power in single rotor wind turbine systems using fuzzy controller based on fractional order error approaches
    Habib Benbouhenni
    Adil Yahdou
    Z. M. S. Elbarbary
    Abdelkadir Belhadj Djilali
    Ilhami Colak
    Saad F. Al-Gahtani
    Scientific Reports, 15 (1)
  • [34] Load Frequency Control of an Interconnected Three-Area Thermal Power System Using Conventional PID & Fuzzy-Logic Controller
    Pati, Tridipta Kumar
    Nayak, Jyoti Ranjan
    Sahu, Binod Kumar
    Gantayat, Bibek
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,
  • [35] Wide-area measurement system-based online calculation method of PV systems de-loaded margin for frequency regulation in isolated power systems
    Liao, Siyang
    Xu, Jian
    Sun, Yuanzhang
    Bao, Yi
    Tang, Bowen
    IET RENEWABLE POWER GENERATION, 2018, 12 (03) : 335 - 341
  • [36] A Load Frequency Control in an Off-Grid Sustainable Power System Based on a Parameter Adaptive PID-Type Fuzzy Controller
    Ronilaya, Ferdian
    Miyauchi, Hajime
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2014, 15 (05) : 429 - 441
  • [37] Frequency Control Strategy for Grid-tied Virtual Power Plant Using SSA-tuned Fractional Order PID Controller
    Abishek, R.
    Das, Dulal Chandra
    Srivastava, Ashtabhuj Kumar
    Latif, Abdul
    IETE JOURNAL OF RESEARCH, 2024, 70 (03) : 2802 - 2818
  • [38] Modified Harris Hawks Optimization-Based Fractional-Order Fuzzy PID Controller for Frequency Regulation of Multi-Micro-Grid
    Sahoo, Gauri
    Sahu, Rabindra Kumar
    Panda, Sidhartha
    Samal, Nayan Ranjan
    Arya, Yogendra
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (11) : 14381 - 14405
  • [39] Modified Harris Hawks Optimization-Based Fractional-Order Fuzzy PID Controller for Frequency Regulation of Multi-Micro-Grid
    Gauri Sahoo
    Rabindra Kumar Sahu
    Sidhartha Panda
    Nayan Ranjan Samal
    Yogendra Arya
    Arabian Journal for Science and Engineering, 2023, 48 : 14381 - 14405
  • [40] Optimized PID controller and model order reduction of reheated turbine for load frequency control using teaching learning-based optimization
    Singh, Anurag
    Yadav, Shekhar
    Tiwari, Nitesh
    Nishad, Dinesh Kumar
    Khalid, Saifullah
    SCIENTIFIC REPORTS, 2025, 15 (01):