Load frequency regulation by de-loaded tidal turbine power plant units using fractional fuzzy based PID droop controller

被引:33
|
作者
Zaheeruddin [1 ]
Singh, Kavita [1 ]
机构
[1] Jamia Millia Islamia, Dept Elect Engn, New Delhi 110025, India
关键词
Tidal energy; Fractional order fuzzy PID controller; Frequency regulation; De-loading operation; Imperialist competitive algorithm; AUTOMATIC-GENERATION CONTROL; SEARCH ALGORITHM; PERFORMANCE; SYSTEMS; OPTIMIZATION; CALCULUS; DESIGN;
D O I
10.1016/j.asoc.2020.106338
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This study presents a model to analyse and simulate tidal power generation for hybrid power system in the presence of highly infiltrated tidal units. The response of the hybrid system may be at risk without suitable frequency enhancement techniques. The complete load frequency model is a combination of conventional automatic generation control (AGC) and automatic voltage regulator (AVR). AVR is employed to keep the output voltage magnitude of conventional generator at a particular level. The purpose of integrating AGC with AVR is to maintain the equilibrium between system's generation and load as well as to keep the frequency of system within suitable range. Owing to inclusion of nonconventional sources, the total inertia of the power system is eventually diminished. Conventional PID droop controller demonstrates inefficacy in diminishing the frequency deviations due to slow controlling action. This research proposes a fractional order (FO) fuzzy PID droop in de-loaded area to improvise the frequency excursion over fixed/Fuzzy PID/PID droop controllers. Imperialist competitive algorithm (ICA) is employed to tune the parameters of the controllers. ICA optimized fractional order PID droop control strategy unveils best performance (settling time = 11.65 s, undershoot amplitude = 0.26pu, performance index = 0.072e-6) over the integer order fuzzy PID control (settling time = 12.02 s, undershoot amplitude = 0.278 pu, performance index = 0.189e-6) and PID droop control (settling time = 30.68 s, undershoot amplitude = 0.95 pu, performance index = 0.215e-6). Examination of dynamic responses for abrupt changes in load request divulges the pre-eminence of proposed droop controller strategy with others controllers. The comprehensive study carried out in this paper implies that ICA optimized controller operates properly and has proven its robustness for +/- 10% variations in system parameters and physical constraints (Generation rate constraints, governor dead band, and time delay). This study also analyses the effect of tidal power plant contribution in the frequency regulation by inertia, primary and secondary frequency control. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Load frequency control by de-loaded wind farm using the optimal fuzzy-based PID droop controller
    Abazari, Ahmadreza
    Monsef, Hassan
    Wu, Bin
    IET RENEWABLE POWER GENERATION, 2019, 13 (01) : 180 - 190
  • [2] Tidal turbine support in microgrid frequency regulation through novel cascade Fuzzy-FOPID droop in de-loaded region
    Singh, Kavita
    Arya, Yogendra
    ISA TRANSACTIONS, 2023, 133 : 218 - 232
  • [3] A generalized piecewise linear time-variable droop frequency controller with adaptive parameters for de-loaded wind turbine generators
    Xu, You-Ning
    Huang, Yu-Chen
    Chen, Yi-Wei
    Chuang, Cheng-Han
    Hsu, Yuan-Yih
    IET RENEWABLE POWER GENERATION, 2022, 16 (08) : 1685 - 1698
  • [4] Load Frequency Control with Considering Impact of Wind Turbine Using a Fractional PID Controller
    Nouri, Navid
    Zamani, Abbas Ali
    Barakati, S. Masoud
    2018 SMART GRID CONFERENCE (SGC), 2018, : 353 - +
  • [5] Wind turbine participation in micro-grid frequency control through self-tuning, adaptive fuzzy droop in de-loaded area
    Abazari, Ahmadreza
    Ghazavi Dozein, Mehdi
    Monsef, Hassan
    Wu, Bin
    IET SMART GRID, 2019, 2 (02) : 301 - 308
  • [6] Frequency support scheme based on parametrized power curve for de-loaded wind turbine under various wind speed
    Zhong, Cheng
    Lv, Yueming
    Li, Huayi
    Chen, JiKai
    Li, Yang
    WIND ENGINEERING, 2022, 46 (02) : 459 - 479
  • [7] Performance Analysis in PID Controller of Turbine Governor Load Frequency Control Using PSO Algorithm and Fuzzy Logic at Nickel Smelting Plant
    Machmoed, Farhan
    Aisjah, Aulia Siti
    ADVANCED INDUSTRIAL TECHNOLOGY IN ENGINEERING PHYSICS, 2019, 2088
  • [8] Area load frequency control using fuzzy PID type controller in a restructured power system
    Shayeghi, H
    Shayanfar, HA
    Jalili, A
    Khazaraee, M
    ICAI '05: PROCEEDINGS OF THE 2005 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE, VOLS 1 AND 2, 2005, : 344 - 350
  • [9] An Optimization of Load Frequency Control Based on Hydraulic Power Plant Using Transfer Function Balanced PID Controller
    Delfianti, Rezi
    Priyadi, Ardyono
    Abadi, Imam
    Budi, Avian Lukman Setya
    Mustaqim, Bima
    Andika, Yudi
    Soeprijanto, Adi
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2021, 13 (06): : 310 - 320
  • [10] Load Frequency Control of Micro Hydro Power Plant using Fuzzy Logic Controller
    Kamble, Suhas Vilas
    Akolkar, S. M.
    2017 IEEE INTERNATIONAL CONFERENCE ON POWER, CONTROL, SIGNALS AND INSTRUMENTATION ENGINEERING (ICPCSI), 2017, : 1783 - 1787