Short Stem Metaphyseal-Engaging Femoral Implants: A Case-Controlled Radiographic and Clinical Evaluation with Eight Year Follow-Up

被引:12
|
作者
Chow, Ian [1 ]
Patel, Ronak M. [1 ]
Stulberg, S. David [1 ]
机构
[1] Northwestern Univ, Dept Orthopaed Surg, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
short stem femoral implants; metaphyseal engaging total hip arthroplasty; TOTAL HIP-ARTHROPLASTY; INCISION ANTERIOR APPROACH; TITANIUM-ALLOY; BONE; COMPONENT; REPLACEMENT; PROSTHESIS; ARTHRITIS; 10-YEAR; OLDER;
D O I
10.1016/j.arth.2014.01.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective comparison of 148 hips in 139 consecutive patients treated with an off-the-shelf uncemented metaphyseal engaging (91-105 mm) stem and 69 hips in 61 patients treated with a custom uncemented metaphyseal engaging short stem was conducted to evaluate the mid-term clinical and radiographic results of an off-the-shelf metaphyseal-engaging short stem implant. All implants were radiographically stable with proximal bony in-growth. There was no significant difference in post-operative HHS (P <. 001) or WOMAC scores (P < .001) between cohorts. An off-the-shelf short femoral stem designed to fit and fill the metaphysis provides reliable fixation up to eight years with equivalent clinical and radiographic results to a customized implant. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:600 / 606
页数:7
相关论文
共 49 条
  • [1] Thigh pain, subsidence and survival using a short cementless femoral stem with pure metaphyseal fixation at minimum 9-year follow-up
    Cinotti, G.
    Della Rocca, A.
    Sessa, P.
    Ripani, F. R.
    Giannicola, G.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (01) : 30 - 36
  • [2] Favorable Results of a Short, Tapered, Highly Porous, Proximally Coated Cementless Femoral Stem at a Minimum 4-Year Follow-Up
    Albers, Anthony
    Aoude, Ahmed A.
    Zukor, David J.
    Huk, Olga L.
    Antoniou, John
    Tanzer, Michael
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04) : 824 - 829
  • [3] Metaphyseal-Loading Anterolaterally-Flared Femoral Stem in Cementless Total Hip Arthroplasty: Five- to Eleven-Year Follow-Up Evaluation
    Kawahara, Hideo
    Kokubo, Yasuo
    Yayama, Takafumi
    Uchida, Kenzo
    Kobayashi, Shigeru
    Nakajima, Hideaki
    Oki, Hisashi
    Negoro, Kohei
    Mwaka, Erisa S.
    Orwotho, Norbert T.
    Baba, Hisatoshi
    ARTIFICIAL ORGANS, 2010, 34 (05) : 377 - 383
  • [4] 5-year clinical and radiographic follow-up of the uncemented Symax hip stem in an international study
    Kruijntjens, Dennis Silvester Maria Gerardus
    Kjaersgaard-Andersen, Per
    Revald, Peter
    Leonhardt, Jane Schwartz
    Arts, Jacobus Johannes Chris
    ten Broeke, Rene Hendrikus Maria
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [5] Reverse shoulder arthroplasty with a cementless short metaphyseal humeral implant without a stem: clinical and radiologic outcomes in prospective 2-to 7-year follow-up study
    Levy, Ofer
    Narvani, Ali
    Hous, Nir
    Abraham, Ruben
    Relwani, Jai
    Pradhan, Riten
    Bruguera, Juan
    Sforza, Giuseppe
    Atoun, Ehud
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (08) : 1362 - 1370
  • [6] Outcome of an uncemented hydroxyapatite coated hemiarthroplasty for displaced femoral neck fractures: a clinical and radiographic 2-year follow-up study
    Eschen, Jacob
    Kring, Soren
    Brix, Michael
    Ban, Ilija
    Troelsen, Anders
    HIP INTERNATIONAL, 2012, 22 (05) : 574 - 579
  • [7] A concise minimum eight year follow-up of proximally porous-coated tapered titanium femoral stem in primary total hip arthroplasty
    Beecher, Benjamin
    Glassner, Philip
    Malchau, Henrik
    Kwon, Young-Min
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (08) : 1561 - 1565
  • [8] Clinical Performance, Patient Reported Outcome, and Radiological Results of a Short, Tapered, Porous, Proximally Coated Cementless Femoral Stem: Results up to Seven Years of Follow-Up
    Ulivi, Michele
    Orlandini, Luca C.
    Meroni, Valentina
    Lombardo, Michele D. M.
    Peretti, Giuseppe M.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04) : 1133 - 1138
  • [9] Clinical and radiographic evaluation of early loaded narrow-diameter implants: 5-year follow-up of a multicenter prospective clinical study
    Galindo-Moreno, Pablo
    Nilsson, Peter
    King, Paul
    Worsaae, Nils
    Schramm, Alexander
    Padial-Molina, Miguel
    Maiorana, Carlo
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (12) : 1584 - 1591
  • [10] Long-term follow-up result of short metaphyseal femoral stem in primary total hip arthroplasty: A retrospective study
    Kumar, Manoj
    Sharma, Ayush
    Ksheerasagar, Vivek P.
    Ghosh, Akash K.
    Lal, Mukund
    WORLD JOURNAL OF ORTHOPEDICS, 2025, 16 (01):