Design and Fabrication of a Capacitance Based Wearable Pressure Sensor Using E-textiles

被引:10
作者
Arogbonlo, A. [1 ]
Usma, C. [1 ]
Kouzani, A. Z. [1 ]
Gibson, I. [1 ]
机构
[1] Deakin Univ, Sch Engn, Waurn Ponds, Vic 3216, Australia
来源
Proceedings of The 1st International Design Technology Conference, DESTECH2015 | 2015年 / 20卷
关键词
E-textiles; Capacitance; Wearable Technology; Pressure; Sensor; SMART TEXTILES; SYSTEMS;
D O I
10.1016/j.protcy.2015.07.043
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper addresses the methods used for the design and fabrication of a capacitance based wearable pressure sensor fabricated using neoprene and (SAC) plated Nylon Fabric. The experimental set up for the pressure sensor is comprised of a shielded grid of sensing modules, a 555 timer based transduction circuitry, and an Arduino board measuring the frequency of signal to a corresponding pressure. The fundamental design parameters addressed during the development of the pressure sensor presented in this paper are based on size, simplicity, cost, adaptability, and scalability. The design approach adopted in this paper results in a sensor module that is less obtrusive, has a thinner and flexible profile, and its sensitivity is easily scalable for 'smart' product applications across industries associated to sports performance, ergonomics, rehabilitation, etc. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:270 / 275
页数:6
相关论文
共 15 条
  • [1] Wearable Monitoring Devices for Assistive Technology: Case Studies in Post-Polio Syndrome
    Andreoni, Giuseppe
    Mazzola, Marco
    Perego, Paolo
    Standoli, Carlo Emilio
    Manzoni, Simone
    Piccini, Luca
    Molteni, Franco
    [J]. SENSORS, 2014, 14 (02): : 2012 - 2027
  • [2] Knitted Strain Sensors: Impact of Design Parameters on Sensing Properties
    Atalay, Ozgur
    Kennon, William Richard
    [J]. SENSORS, 2014, 14 (03): : 4712 - 4730
  • [3] Assessment of Lower Limb Prosthesis through Wearable Sensors and Thermography
    Cutti, Andrea Giovanni
    Perego, Paolo
    Fusca, Marcello C.
    Sacchetti, Rinaldo
    Andreoni, Giuseppe
    [J]. SENSORS, 2014, 14 (03): : 5041 - 5055
  • [4] Enokibori Y., 2013, Conference on Pervasive and Ubiquitous Computing, P207, DOI [10.1145/2494091.2494158, DOI 10.1145/2494091.2494158]
  • [5] Holleczek T., 2010, SENSORS
  • [6] Comparison of capacitive versus resistive joint contact stress sensors
    Martinelli, L.
    Hurschler, C.
    Rosenbaum, D.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (447) : 214 - 220
  • [7] Meyer J., 2006, WEAR COMP 2006 10 IE
  • [8] Smart Textiles: Wearable Electronic Systems
    Sungmee Park
    Sundaresan Jayaraman
    [J]. MRS Bulletin, 2003, 28 (8) : 585 - 591
  • [9] Shieldex Trading Inc, 2012, PROD IND
  • [10] Wearable Electronics and Smart Textiles: A Critical Review
    Stoppa, Matteo
    Chiolerio, Alessandro
    [J]. SENSORS, 2014, 14 (07): : 11957 - 11992