Capabilities of inductively coupled plasma mass spectrometry for the detection of nanoparticles carried by monodisperse microdroplets

被引:127
作者
Gschwind, Sabrina [1 ]
Flamigni, Luca [1 ]
Koch, Joachim [1 ]
Borovinskaya, Olga [1 ]
Groh, Sebastian [2 ]
Niemax, Kay [3 ]
Guenther, Detlef [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Chem & Appl Biosci, Inorgan Chem Lab, CH-8093 Zurich, Switzerland
[2] Leibniz Inst Analyt Wissensch ISAS, D-44139 Dortmund, Germany
[3] BAM Fed Inst Mat Res & Testing, Div Analyt Chem & Reference Mat 1, D-12489 Berlin, Germany
关键词
DRIED MICROPARTICULATE INJECTOR; COLLOID ANALYSIS; SILVER NANOPARTICLES; SAMPLE DROPLETS; GAS; FLAME; ICP;
D O I
10.1039/c0ja00249f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently, first analyses of single sub-micrometre particles, embedded in liquid droplets, by inductively coupled plasma optical emission spectrometry (ICP-OES) with a size-equivalent detection limit of several hundred nanometres were reported. 1,2 To achieve lower detection limits which might allow for the analysis of particles in the nanometre size range a more sensitive technique such as mass spectrometry (MS) is required. Various modifications of particle delivery and data acquisition systems commonly used were carried out to install a setup adequate for ICP-MS detection. These modifications enabled us to supply droplets generated by a commercial microdroplet generator (droplet size: 30-40 mm) with nearly 100% efficiency and high uniformity to the ICP. Analyses were performed using both standard solutions of dissolved metals at concentrations of 1 (Ag), 2 (Au), 5 (Au), or 10 (Cu) mg L-1 and highly diluted suspensions of gold and silver nanoparticles with sizes below 110 nm. In doing so, detection efficiencies of 10(-6) counts per atom could be achieved while size-related limits of quantification were found to be 21 nm and 33 nm for gold and silver, respectively. Furthermore, the advantages of utilizing microdroplet generators vs. conventional nebulizers for nanoparticle analyses by ICP-MS are discussed.
引用
收藏
页码:1166 / 1174
页数:9
相关论文
共 33 条
[21]   The kinetics of the tissue distribution of silver nanoparticles of different sizes [J].
Lankveld, D. P. K. ;
Oomen, A. G. ;
Krystek, P. ;
Neigh, A. ;
Troost-de Jong, A. ;
Noorlander, C. W. ;
Van Eijkeren, J. C. H. ;
Geertsma, R. E. ;
De Jong, W. H. .
BIOMATERIALS, 2010, 31 (32) :8350-8361
[22]   A direct injection high-efficiency nebulizer for inductively coupled plasma mass spectrometry [J].
McLean, JA ;
Zhang, H ;
Montaser, A .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :1012-1020
[23]   Measurement of element mass distributions in particle ensembles applying ICP-OES [J].
Murtazin, Ayrat ;
Groh, Sebastian ;
Niemax, Kay .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (09) :1395-1401
[24]   MONODISPERSE DRIED MICROPARTICULATE INJECTOR - A NEW TOOL FOR STUDYING FUNDAMENTAL PROCESSES IN INDUCTIVELY-COUPLED PLASMAS [J].
OLESIK, JW ;
HOBBS, SE .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3371-3378
[25]   Investigating the fate of individual sample droplets in inductively coupled plasmas [J].
Olesik, JW .
APPLIED SPECTROSCOPY, 1997, 51 (05) :A158-A175
[26]   Silver or silver nanoparticles: a hazardous threat to the environment and human health? [J].
Panyala, Nagender Reddy ;
Maria Pena-Mendez, Eladia ;
Havel, Josef .
JOURNAL OF APPLIED BIOMEDICINE, 2008, 6 (03) :117-129
[27]   SIMPLE AND INEXPENSIVE DESIGN FOR AN ISOLATED DROPLET GENERATOR USEFUL IN STUDIES OF ATOMIZATION IN FLAMES [J].
RUSSO, RE ;
WITHNELL, R ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1981, 35 (06) :531-536
[28]   SMOOTHING + DIFFERENTIATION OF DATA BY SIMPLIFIED LEAST SQUARES PROCEDURES [J].
SAVITZKY, A ;
GOLAY, MJE .
ANALYTICAL CHEMISTRY, 1964, 36 (08) :1627-&
[29]   Continuous simultaneous detection in mass Spectrometry [J].
Schilling, Gregory D. ;
Andrade, Francisco J. ;
Barnes, James H. ;
Sperline, Roger P. ;
Denton, M. Bonner ;
Barinaga, Charles J. ;
Koppenaal, David W. ;
Hieftje, Gary M. .
ANALYTICAL CHEMISTRY, 2007, 79 (20) :7662-7668
[30]   Evaluation of a 512-Channel Faraday-Strip Array Detector Coupled to an Inductively Coupled Plasma Mattauch-Herzog Mass Spectrograph [J].
Schilling, Gregory D. ;
Ray, Steven J. ;
Rubinshtein, Arnon A. ;
Felton, Jeremy A. ;
Sperline, Roger P. ;
Denton, M. Bonner ;
Barinaga, Charles J. ;
Koppenaal, David W. ;
Hieftje, Gary M. .
ANALYTICAL CHEMISTRY, 2009, 81 (13) :5467-5473