Capabilities of inductively coupled plasma mass spectrometry for the detection of nanoparticles carried by monodisperse microdroplets

被引:126
作者
Gschwind, Sabrina [1 ]
Flamigni, Luca [1 ]
Koch, Joachim [1 ]
Borovinskaya, Olga [1 ]
Groh, Sebastian [2 ]
Niemax, Kay [3 ]
Guenther, Detlef [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Chem & Appl Biosci, Inorgan Chem Lab, CH-8093 Zurich, Switzerland
[2] Leibniz Inst Analyt Wissensch ISAS, D-44139 Dortmund, Germany
[3] BAM Fed Inst Mat Res & Testing, Div Analyt Chem & Reference Mat 1, D-12489 Berlin, Germany
关键词
DRIED MICROPARTICULATE INJECTOR; COLLOID ANALYSIS; SILVER NANOPARTICLES; SAMPLE DROPLETS; GAS; FLAME; ICP;
D O I
10.1039/c0ja00249f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently, first analyses of single sub-micrometre particles, embedded in liquid droplets, by inductively coupled plasma optical emission spectrometry (ICP-OES) with a size-equivalent detection limit of several hundred nanometres were reported. 1,2 To achieve lower detection limits which might allow for the analysis of particles in the nanometre size range a more sensitive technique such as mass spectrometry (MS) is required. Various modifications of particle delivery and data acquisition systems commonly used were carried out to install a setup adequate for ICP-MS detection. These modifications enabled us to supply droplets generated by a commercial microdroplet generator (droplet size: 30-40 mm) with nearly 100% efficiency and high uniformity to the ICP. Analyses were performed using both standard solutions of dissolved metals at concentrations of 1 (Ag), 2 (Au), 5 (Au), or 10 (Cu) mg L-1 and highly diluted suspensions of gold and silver nanoparticles with sizes below 110 nm. In doing so, detection efficiencies of 10(-6) counts per atom could be achieved while size-related limits of quantification were found to be 21 nm and 33 nm for gold and silver, respectively. Furthermore, the advantages of utilizing microdroplet generators vs. conventional nebulizers for nanoparticle analyses by ICP-MS are discussed.
引用
收藏
页码:1166 / 1174
页数:9
相关论文
共 33 条
[1]  
[Anonymous], 2007, NANOPARTICLE TECHNOL
[2]   Estimation of cumulative aquatic exposure and risk due to silver:: Contribution of nano-functionalized plastics and textiles [J].
Blaser, Sabine A. ;
Scheringer, Martin ;
MacLeod, Matthew ;
Hungerbuehler, Konrad .
SCIENCE OF THE TOTAL ENVIRONMENT, 2008, 390 (2-3) :396-409
[3]   EXPERIMENTAL STUDIES ON SPATIAL DISTRIBUTIONS OF ATOMS SURROUNDING AN INDIVIDUAL SOLUTE PARTICLE VAPORIZING IN AN ANALYTICAL FLAME [J].
BOSS, CB ;
HIEFTJE, GM .
ANALYTICAL CHEMISTRY, 1979, 51 (12) :1897-1905
[4]  
Chapman S., 1990, Thermal Conduction and Diffusion in Gases
[5]   Uranium colloid analysis by single particle inductively coupled plasma-mass spectrometry [J].
Degueldre, C ;
Favarger, PY ;
Rossé, R ;
Wold, S .
TALANTA, 2006, 68 (03) :623-628
[6]   Gold colloid analysis by inductively coupled plasma-mass spectrometry in a single particle mode [J].
Degueldre, C ;
Favarger, PY ;
Wold, S .
ANALYTICA CHIMICA ACTA, 2006, 555 (02) :263-268
[7]   Zirconia colloid analysis by single particle inductively coupled plasma-mass spectrometry [J].
Degueldre, C ;
Favarger, PY ;
Bitea, C .
ANALYTICA CHIMICA ACTA, 2004, 518 (1-2) :137-142
[8]   Thorium colloid analysis by single particle inductively coupled plasma-mass spectrometry [J].
Degueldre, C ;
Favarger, PY .
TALANTA, 2004, 62 (05) :1051-1054
[9]   GAS-DYNAMICS OF THE INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY INTERFACE [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :743-747
[10]   Time resolved inductively coupled plasma mass spectrometry measurements with individual, monodisperse drop sample introduction [J].
Dziewatkoski, MP ;
Daniels, LB ;
Olesik, JW .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1101-1109